| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| vde0700 | DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY 25.0 .984 DE RELAYS (ADE) FEATURES 12.5 .492 12.5 .492 mm inch • Conforms to European safety standards (VDE0700 and VDE0631) Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch |
Original | ||||
| DE (ADE) VDE DE RELAYS (ADE) COMPACT | DE (ADE) VDE DE RELAYS (ADE) COMPACT HIGH-INSULATION POLARIZED POWER RELAY FEATURES 25.0 .984 12.5 .492 • Conforms to VDE0631. Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch • Extensive product line-up. |
Original | ||||
| 415va | Issued March 1999 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated |
Original | ||||
| iec292 | Issued March 1997 232-3355 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed |
Original | ||||
| iec158 | Issued March 1997 232-4493 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated |
Original | ||||
| bs5424 | Issued November 1990 B11044 Direct on line (dol) starters 0.5 to 10hp415Vac Features l Protected to IP54 l Robust sheet steel enclosure l 3-pole contactor to BS5424; IEC158-1 and VDE0660 l 20mm conduit entries. Robust direct on line ac starters complying with |
Original | ||||
| bs54 | Issued March 1994 017-064 Data Pack B Data Sheet Direct on line (DOL) starters 0.5 to 10hp 415Vac Protected to IP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated |
Original | ||||
| iec 158-1 | 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage (Ui) (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4 |
Original | ||||
| N e w G e n e r a t i o n of C o m p o s i t e C | N e w G e n e r a t i o n of C o m p o s i t e C o n n e c t o r S eries 5 4 4 MÀ S E C T IO N Protected and non protected versions against EMI and RFI. Important dielectric with grounding contact. B Innovative Push-Pull locking. B In conformity with IEC 48B/560/CD and VDE0627 |
OCR Scan | ||||
| iec292 | Issued November 1990 011-044 Data Pack B Direct on line (dol) starters 0.5 to 10hp 415Vac Data Sheet Robust direct on line ac starters complying with BS4941; IEC292 and VDE0660. Each unit is supplied ready wired with a 3-pole contactor. To complete the assembly an overload relay to match the full load current of the motor must be selected (Table 2). Housed |
Original | ||||
| DE (ADE) VDE Compliant with European standards | DE (ADE) VDE Compliant with European standards 1a1b 10A/8A polarized power relays RoHS compliant DE RELAYS (ADE) FEATURES TYPICAL APPLICATIONS 1. Conforms to European safety standard (VDE0700 and VDE0631). Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch |
Original | ||||
| vde0700 | DE (ADE) VDE Compliant with European standards 1a1b 10A/8A polarized power relays Compliance with RoHS Directive DE RELAYS (ADE) FEATURES TYPICAL APPLICATIONS 1. Conforms to European safety standard (VDE0700 and VDE0631). Insulating distance between coil and |
Original | ||||
| DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED | DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY FEATURES 12.5 .492 25.0 .984 DE RELAYS (ADE) 12.5 .492 mm inch • Conforms to European safety standards (VDE0700 and VDE0631) Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch |
Original | ||||
| vde0631 | DE VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY DE RELAYS FEATURES 25.0 .984 • Conforms to VDE0631. Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch 12.5 .492 12.5 .492 • Extensive product line-up. |
Original | ||||
|
|
||||||
| vde0700 | DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY 25.0 .984 DE RELAYS (ADE) FEATURES 12.5 .492 12.5 .492 mm inch • Conforms to European safety standards (VDE0700 and VDE0631) Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch |
Original | ||||
| hrc fuse | Bussmann® NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 500V AC, 10 to 630 Amps Sizes 000 to 3 Standards/ Approvals: CATALOGUE SYMBOL: (amp)NHG(Size)B HRC FUSE LINKS CLASS OF OPERATION gL/gG 500V AC 10 to 630 AMPS SIZES 000 to 3 IEC 60269, VDE0636, |
Original | ||||
| vde0631 | DE VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY DE RELAYS FEATURES 25.0 .984 • Conforms to VDE0631. Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch 12.5 .492 12.5 .492 • Extensive product line-up. |
Original | ||||
| vde0631 | DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY DE RELAYS (ADE) FEATURES 25.0 .984 12.5 .492 • Conforms to VDE0631. Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch • Extensive product line-up. |
Original | ||||
| bs5424 | B17064 Issued March 1994 Directonline(DOL)starters 0.5to10hp415VacProtectedtoIP66 4 pole direct on line ac starters, manufactured to BS5424; IEC158 and VDE0660 standards. Certified by CSA and Lloyd's. Housed in a compact all insulated enclosure environmentally protected to IP66. The |
Original | ||||
| w w w . a l t e c h c o r p . c o m 22 & 30mm | w w w . a l t e c h c o r p . c o m 22 & 30mm Push Buttons, Selector Switches & LED Pilot Lights P R O D U C T • L I N E S Miniatur e Cir cuit Br eakers DIN Enclosur es Electr onic Enclosur es Eur opean Fuses |
Original | ||||
| d-3000 | AMP Dynamic Series Connectors D-3000 Series (Wire-to-Board, Wire-to-Panel and Wire-to-Wire) List of Products by Application Tab Housing Used for both signal circuit and power/power supply circuit applications. D-3000 Series Able to carry 15A max. of current per position and are |
Original | ||||
| azm 160 | Solenoid interlocks AZM 160 range 28 • Voltage variants • 24 VAC/DC • 110 VAC • 230 VAC Always state required supply voltage when ordering 78 72 Thermoplastic enclosure Manual / Emergency release Long life Double insulated X |