Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    VDE 0435-2021 TIMER Search Results

    VDE 0435-2021 TIMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    7832C0435X01LF
    Amphenol Communications Solutions Smart Card Reader, Input Output Connectors, Connectors for Vandalism Proof, 16 contacts, Harsh Environment, Module Type, Lead Free. PDF
    7434L0435S01LF
    Amphenol Communications Solutions Smart Card, Input Output Connectors, L04 Series, 16Pins, 9mm Height, Normal Open, Outdoor. PDF
    61083-043502PLF
    Amphenol Communications Solutions BergStak® 0.80mm Pitch, Mezzanine Connector, Vertical Header, Double Row, 40 Positions. PDF
    10043546-101LF
    Amphenol Communications Solutions AirMax VS®, Backplane Connectors, 3-Pair, 54 -position, 2mm pitch, 6 column, Vertical Receptacle. PDF
    61083-043502LF
    Amphenol Communications Solutions BERGSTAK 0.8MM HDR 40POS. PDF

    Documents mentioning VDE 0435-2021 TIMER

    Document Partial File Text Tags Type PDF
    TOP 48 panel-mounted electronic timers with
    TOP 48 panel-mounted electronic timers with analogue setting Relay output ■ Multi-function or mono-function Multi-range Multi-voltage or mono-voltage 1 or 2 changeover relays Display of output states by 2 LEDs Connection by 8-pin base or 11-pin base
    Original PDF
    crouzet
    www.crouzet.com 88857003-Timer 814 LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in the event of a break in supply (Timer 815, 815E) Access to programming lockable (Timer 814, 815 and 815E)
    Original PDF
    crouzet
    www.crouzet.com 88857105-Timer 814 LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in the event of a break in supply (Timer 815, 815E) Access to programming lockable (Timer 814, 815 and 815E)
    Original PDF
    Panel-mounted timers LCD TIMER (814 - 815 and
    Panel-mounted timers LCD TIMER (814 - 815 and 816) (48 x 48 mm) with digital display and relay output Red LED display (816) LCD display (814-815) Multi-function or mono-function Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timer 815)
    Original PDF
    88857406
    05/09/2012 www.crouzet.com 812 - 814 - 815 - 815 E digital timers Timer 812 Part number 88857406 LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in the event of a break in supply (Timer 815, 815E)
    Original PDF
    Electronic timer CT-VWD Impulse-ON with 1 c/o
    Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Characteristics CT-VWD 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine adjustment of the pulse time
    Original PDF
    88857105
    05/09/2012 www.crouzet.com 812 - 814 - 815 - 815 E digital timers Timer 814 Part number 88857105 LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in the event of a break in supply (Timer 815, 815E)
    Original PDF
    05/09/2012 www.crouzet.com 812 - 814 - 815 - 815
    05/09/2012 www.crouzet.com 812 - 814 - 815 - 815 E digital timers Timer 814 Part number 88857005 LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in the event of a break in supply (Timer 815, 815E)
    Original PDF
    timer 814
    812/ 814/ 815 digital timers ➜ 812 - 814 - 815 Relay output digital timer ■ Multi-range ■ Multi-voltage ■ 1 or 2 relay outputs ■ Reset function on panel (Timers 815) ■ Data saved in the event of a break in supply (Timer 815) ■ Access to programming lockable (Timer 814 and 815)
    Original PDF
    Electronic timer CT-VWD.12 2CDC 251 095 F0t06
    Electronic timer CT-VWD.12 2CDC 251 095 F0t06 Impulse-ON with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer impulse‑ON 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-ERD.12 2CDC 251 092 F0t06
    Electronic timer CT-ERD.12 2CDC 251 092 F0t06 ON-delayed with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer ON‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-EBD.12 2CDC 251 096 F0t06
    Electronic timer CT-EBD.12 2CDC 251 096 F0t06 Flasher starting with ON with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer flasher, starting with ON
    Original PDF
    Electronic timer CT-ERD.22 2CDC 251 091 F0t06
    Electronic timer CT-ERD.22 2CDC 251 091 F0t06 ON-delayed with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer ON‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-TGD.12 2CDC 251 098 F0t06
    Electronic timer CT-TGD.12 2CDC 251 098 F0t06 Pulse generator with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer pulse generator 2 x 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    pulse generator
    Electronic timer CT-TGD.22 2CDC 251 097 F0t06 Pulse generator with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer pulse generator 2 x 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    ct-sdd.22
    Electronic timer CT-SDD.22 2CDC 251 099 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer star‑delta change‑over
    Original PDF
    Electronic timer CT-AHD.22 2CDC 251 093 F0t06
    Electronic timer CT-AHD.22 2CDC 251 093 F0t06 OFF-delayed with 2 c/o contacts Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer OFF‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    electronic timer
    Electronic timer CT-SAD.22 2CDC 251 100 F0t06 Star-delta change-over with 2 n/o contacts Data sheet � Features  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer star‑delta change‑over
    Original PDF
    Electronic timer CT-AHD.12 2CDC 251 094 F0t06
    Electronic timer CT-AHD.12 2CDC 251 094 F0t06 OFF-delayed with 1 c/o contact Data sheet Features �  Rated control supply voltage 24‑48 V DC, 24‑240 V AC Single‑function timer OFF‑delay 7 time ranges (0.05 s ‑ 100 h) in one device
    Original PDF
    Electronic timer CT-SDS.22 2CDC 251 083 F0t06
    Electronic timer CT-SDS.22 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function timer with star-delta change-over
    Original PDF
    Electronic timer CT-ERS.21 ON-delayed with 2 c/o
    Electronic timer CT-ERS.21 ON-delayed with 2 c/o contacts Data sheet 2CDC 251 057 F0t07 Features ᕃ ᕅ ᕆ ᕄ ᕇ a  Rotary switch for the preselection of the time range b  Potentiometer with direct reading scale for the fine adjustment of the time
    Original PDF
    Electronic timer CT-SDS.23 2CDC 251 083 F0t06
    Electronic timer CT-SDS.23 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ Rated control supply voltage 380-440 V AC/DC Single-function timer with star-delta change-over One device includes 7 time ranges (0.05 s - 10 min)
    Original PDF
    Electronic timer CT-ARS.11 OFF-delayed without
    Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o contact Data sheet 2CDC 251 088 F0t07 Features ᕃ ᕅ ᕄ ᕆ  Rated control supply voltage 24‑240 V AC/DC Single‑function OFF‑delay timer without auxiliary voltage
    Original PDF
    Electronic timer CT-ARS.21 OFF-delayed without
    Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o contacts Data sheet 2CDC 251 089 F0t07 Features ᕃ ᕅ ᕄ ᕆ  Rated control supply voltage 24‑240 V AC/DC Single‑function OFF‑delay timer without auxiliary voltage
    Original PDF