Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    VA VAR VALVE Search Results

    VA VAR VALVE Result Highlights (4)

    Part ECAD Model Manufacturer Description Download Buy
    DRV110APWR
    Texas Instruments Single-Channel Relay, Solenoid, Valve Low-Side Controller With Current Regulation 14-TSSOP -40 to 125 Visit Texas Instruments Buy
    DRV110PWR
    Texas Instruments Single-Channel Relay, Solenoid, Valve Low-Side Controller With Current Regulation 8-TSSOP -40 to 125 Visit Texas Instruments Buy
    DRV120PWR
    Texas Instruments DRV120 Single-Channel Relay, Solenoid, Valve Low-Side Driver With Current Regulation 8-TSSOP -40 to 105 Visit Texas Instruments Buy
    DRV103U/2K5
    Texas Instruments PWM Low Side Driver (1.5A/3A) for Solenoids, Coils, Valves, Heaters, and Lamps 8-SOIC Visit Texas Instruments Buy

    Documents mentioning VA VAR VALVE

    Document Partial File Text Tags Type PDF
    137b
    BR137B/JULY 1954 v in o n i Triode Type BR 137B HF AMPLIFIER AND OSCILLATOR _4 703_ . DIA.. General. The BR 137B is a forced-air-cooled trans­ mitting triode fitted with a tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the
    OCR Scan PDF
    rxma1
    Auxiliary, signalling and tripping relays RXMA1, RXMA 2, RXMM 1 RXMS 1, RXSF 1, RXME 1, RXME 18, RXMH 2 & RXMT 1 RXMM 1 (SE 90 06 16) RXSF 1 (SE 82 02 62) (SE 82 02 62) (SE 94 07 44) (SE 94 07 41) Page 1 Issued July 2007 Revision: B Data subject to change without notice
    Original PDF
    MITSUBISHI ELECTRIC INDICATORS and TRANSDUCERS
    MITSUBISHI ELECTRIC INDICATORS and TRANSDUCERS Table of Contents (Mechanical Indicators) ᭿Overview and Features…3 ᭿Safety Precautions…5 ᭿Selection Precautions…9
    Original PDF
    Motor Management Relay® 7 Complete, optimum motor
    Motor Management Relay® 7 Complete, optimum motor protection for maximum rated output. Features and Benefits Applications ■ Digital technology ■ Adapts to each application by “learning” individual motor parameters Protection and monitoring for threephase motors and their associated
    Original PDF
    TP. 2620 A C/D C M AINS T R IO D E PEN TO D E R A
    TP. 2620 A C/D C M AINS T R IO D E PEN TO D E R A T IN G . H e ate r V o ltag e… H e ate r C u r r e n t (am ps.)… 26 0.2 P e n t o d e S e c t io n .
    OCR Scan PDF
    cal controls
    Operating Manual CAL Controls Temperature Controllers CAL 3300 and 9300 Autotune Temperature Controllers CAL Controls Ltd Bury Mead Road, Hitchin, Herts, SG5 1RT. UK Tel: + 44 (0)1462-436161 Fax: + 44 (0)1462-451801 email: support@cal-controls.co.uk http://www.cal-controls.com
    Original PDF
    PA SERIES Rigid Mounting • Up to 15W Dissipation
    PA SERIES Rigid Mounting • Up to 15W Dissipation • Voltage Range 130-575 V RMS, 170-750 VDC • Peak Pulse Current to 4000A • Meets NEMA Creep and Strike Distance • For Complete Specifications, see Page No. 1432. M A X IM U M AC RMS AC-PEAK 50-60HZ
    OCR Scan PDF
    PROTECTION RELAYS & CONTROLS CATALOG  Protection
    PROTECTION RELAYS & CONTROLS CATALOG  Protection Relays & Controls Catalog  Ground-Fault Protection • Motor & Pump Protection • Feeder Protection Arc-Flash Protection • Custom Products • Generator Protection & Controls Engine Controls & Diagnostics • Alarm Monitoring
    Original PDF
    Smart Metering Solutions Rolf Hertel – Global
    Smart Metering Solutions Rolf Hertel – Global Applications Marketing Neal Frager – Smart Metering Applications Engineer October 2010 Smart Metering Selling Guide 2 What is Smart Metering? 3 Stakeholders in Smart Metering Governments rule regulations to reduce CO2 emissions and
    Original PDF
    SM ALL-SIGNAL TRANSISTORS page Selection guide A
    SM ALL-SIGNAL TRANSISTORS page Selection guide A udio and general purpose a p p lica tio n s… 5 HF applications…
    OCR Scan PDF
    070 Series ANSI Switchboard Meters Approvals UL
    070 Series ANSI Switchboard Meters Approvals UL Approved File No: E87815 This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 (1981) accuracy class 1. Available in two case sizes, their rugged design characteristics
    Original PDF
    philips components
    Philips Components Varistors Introduction to Varistors GENERAL VARISTOR MANUFACTURING PROCESS Varistors provide reliable and economical protection against high voltage transients and surges which may be produced, for example, by lightning, switching or electrical
    OCR Scan PDF
    CHAUVIN ARNOUX 10 SUBSIDIARIES WORLDWIDE Chauvin
    CHAUVIN ARNOUX 10 SUBSIDIARIES WORLDWIDE Chauvin Arnoux Ges.m.b.H Slamastrasse 29/2/4 1230 WIEN Tel.: +43 1 61 61 9 61 Fax: +43 1 61 61 9 61-61 vie-office@chauvin-arnoux.at www.chauvin-arnoux.at CHINA ENERDIS 16, rue Georges Besse - Silic 44 92182 ANTONY Cedex
    Original PDF
    07
    070 Series ANSI Switchboard Meters This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 (1981) accuracy class 1. Available in 41/2" and 83/4" case sizes, their rugged design characteristics suit the most demanding of environmental
    Original PDF
    Product catalog ACS Environmental Controls
    Product catalog ACS Environmental Controls Honeywell Srl ACS Environmental Controls Via Philips, 12 20052 Monza Telefono: +39 039 2165.1 Email: info@honeywell.it Honeywell ΕΠΕ ACS Environmental Controls Πολυτεχενείου, 25 14122, Νέο Ηράκλειο
    Original PDF
    cal 3300
    F r a n ç a i s D e u t s c h CAL 3300 / 9300 / 9400 Autotune Temperature Controllers E n g l i s h Users Manual I t a l i a n o Temperature Controllers E s p a ñ o l CAL Controls E n g l i s h INDEX FUNCTIONS MENU GETTING STARTED Initial Set-up AUTOTUNE
    Original PDF
    Varför skall man använda säkerhetssystem Vital?
    Varför skall man använda säkerhetssystem Vital? Why you should use the Vital safety system Inkoppling av återställning – Vital 1 Godkännande: Manuell övervakad återställning Automatisk återställning Test B1 Användning: Säkerhetslösning med många olika
    Original PDF
    Motor Control (AMPGARD)—Medium Voltage 10.0-1
    Motor Control (AMPGARD)—Medium Voltage 10.0-1 July 2014 Motor Control (AMPGARD) —Medium Voltage Sheet 10 001 CA08104001E Contents Motor Control (AMPGARD)—Medium Voltage Motor Starters General Description Application and Features…
    Original PDF
    OIL STEAM COMPRESSED AIR SPECIALIST METERS
    OIL STEAM COMPRESSED AIR SPECIALIST METERS www.mwatechnology.com g ce GAS ENERGY WATER ELECTRICITY ce Extended product range now available t tradi n en d INDEPENDENT METERING SPECIALISTS years 1993 - 2013 . re ra ti 0 year g2 s n indepen of ing th ep rat b
    Original PDF
    2659 Technical portal and online community for
    2659 Technical portal and online community for Design Engineers - www.element-14.com Process Control, Timers & Counters Page Process Control Analogue Signal Conditioners… Current and Voltage Controls… DIN / Energy - Meters…
    Original PDF
    SMALL-SIGNAL FIELD-EFFECT TRANSISTORS page
    SMALL-SIGNAL FIELD-EFFECT TRANSISTORS page Selection guide N-channel junction field-effect transistors general purpose… for differential am plifiers…
    OCR Scan PDF
    In consideration of modifications to Standards
    In consideration of modifications to Standards and materials, the characteristics and overall dimensions indicated in this catalogue may be considered binding only following confirmation by ABB Copyright 2010 ABB. All right reserved. System pro M compact® and other modular devices for low voltage installation
    Original PDF
    Technical catalogue System pro M compact® and
    Technical catalogue System pro M compact® and other modular devices for low voltage installation System pro M compact® and other modular devices for low voltage installation In consideration of modifications to Standards and materials, the characteristics
    Original PDF