| mc2863sp | MOrOROLA @ I 1 I MC2863SP I H7X H6Y H6X H5Y a g,n J 16 15 HOX HOY HIX HIY H2X u 1 DSJO06 12V 5V ‘ccivDDhwus ,VCT ,&&yq p_______________ I I h I dd WRITE CENTER UNSAFE TAP DETECTOR DRIVER I ..-, H4X D L H4Y I H5X II I II I — t L L–––~_~_______ RDX |
Original | ||||
| i^ V T C Incorporated READ W RITE THIN FILM P R E | i^ V T C Incorporated READ W RITE THIN FILM P R E A M P L IF IE R S FEATURES • Power Up/Down Protection Circuitry • Operates on +5V and +12V Power Supplies • Programmable Write-Current Source • TTL-Compatible Control Lines • Write-Unsafe Detection Circuitry |
OCR Scan | ||||
| SAFETY ALERT SYMBOL INSTRUCTION MANUAL 77GX - | SAFETY ALERT SYMBOL INSTRUCTION MANUAL 77GX - 77GX2 - 150D TONE GENERATORS This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message |
Original | ||||
| Introduction SAFETY ALERT SYMBOL INSTRUCTION | Introduction SAFETY ALERT SYMBOL INSTRUCTION MANUAL PE620 ALARM LOOP VERIFIER TONE GENERATOR This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message |
Original | ||||
| Positronic Industries Presents POWER CONNECTION | Positronic Industries Presents POWER CONNECTION SYSTEMS WITH SAFETY SHROUD FEATURE Size 12 Power Contacts Large Surface Area Mating System High Reliability Integral Locking System Safety Shrouded to Prevent Unsafe Exposure in Applications where Male Contacts are Energized when |
Original | ||||
| Temporary Power Over-The-Floor Power Duct | Temporary Power Over-The-Floor Power Duct Over-The-Floor Power Duct Selection Guide • Low-profile cable duct lays flat and provides an economical means of supplying power where needed. • Helps to eliminate hazards of unsafe extension cord strung over floor. Hugs the floor, protects against tripping. |
Original | ||||
| si-ls42 | Machine Safety Switches ® SI-LS42 Series Locking Style Switch WARNING… Spare actuators must NEVER be used to bypass or otherwise defeat the protective function of a safety switch. To do so may create an unsafe situation which could lead to serious injury or death. |
Original | ||||
| si-ls42 | Machine Safety Switches ® SI-LS42 Series Locking Style Switch WARNING… Spare actuators must NEVER be used to bypass or otherwise defeat the protective function of a safety switch. To do so may create an unsafe situation which could lead to serious injury or death. |
Original | ||||
| avr998 | AVR998: Guide to IEC60730 Class B compliance with AVR microcontrollers 1. Overview The International Electrotechnical Commission has introduced the IEC60730 referring to household appliances development. The annex H of IEC60730 describes three software classifications. The second one, the Class B refers to the embedded firmware which are intended to prevent unsafe operation of the controlled equipment. |
Original | ||||
| ds1231 | Maxim > Products > [Supervisors, Voltage Monitors, Sequencers] DS1231 Power Monitor Description With precise, temperature-compensated comparators, the DS1231 Power Monitor Chip monitors input power and a 5V system power supply. If unsafe voltages are detected, a nonmaskable interrupt sends a warning signal to the processor in advance of power failure. Processing is unconditionally halted |
Original | ||||
| Power Connection Systems SAFETY SHROUD FEATURE | Power Connection Systems SAFETY SHROUD FEATURE Power Connection Systems Safety Shrouded Connector to Prevent Unsafe Exposure to High Energy Circuits * Size 12 Power Contacts * Large Surface Area Mating System * Discriminating Locking System * Contact Current Rating to |
Original | ||||
| SAFETY ALERT SYMBOL INSTRUCTION MANUAL MODEL | SAFETY ALERT SYMBOL INSTRUCTION MANUAL MODEL 600LS TEST SET This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message |
Original | ||||
| guardmaster lifeline 4 | Product Safety Group 1201 South Second Street Milwaukee, WI USA 53204 productsafety@ra.rockwell.com PRODUCT SAFETY ADVISORY Notice of Potential Unsafe Condition GuardMaster Lifeline 4 Cable Pull Switches Reference: 2010-05-001 Revision: A Date: May 2010 June 2010 |
Original | ||||
| V y fe i M 1 1 R 7 July, 1992 FEA TURES • Power | V y fe i M 1 1 R 7 July, 1992 FEA TURES • Power Up/Down Write Protection • Operates on +5V and +12V Power Supplies • Programmable Write-Current Source • TTL-Compatible Control Lines • Write-Unsafe Detection Circuitry • Low Input Noise • For Use With Center-Tapped Ferrite Heads |
OCR Scan | ||||
|
|
||||||
| mc2860m | - O M MOTOROLA I I MC2860M . 1 DSJO05 12V 5V 1% v[~y!_~:_________+.L______________---l m WRITE UNSAFE DETECTOR I I CENTER TAP DRIVER t READ CURRENT SOURCE w WDI HEAD SELECT I , 1 , I L_ MOTOROU ————————— AA 2 L I A H3Y ,*%’<*<,*$ |
Original | ||||
| Application Note Active PFC for Electronic Power | Application Note Active PFC for Electronic Power Supplies The proliferation of electronic loads on power distribution systems has led to inefficient and unsafe conditions due to the typically poor power factor of electronic power conversion equipment. Waveform distortion and the |
Original | ||||
| Positronic Industries Presents POWER CONNECTION | Positronic Industries Presents POWER CONNECTION SYSTEMS WITH SAFETY SHROUD FEATURE Size 12 Power Contacts Large Surface Area Mating System High Reliability Integral Locking System Safety Shrouded to Prevent Unsafe Exposure in Applications where Male Contacts are Energized when |
Original | ||||
| V M 1 1 8 L /V M 1 1 8 L R READ/W RITE | V M 1 1 8 L /V M 1 1 8 L R READ/W RITE PREAMPLIFIER FOR CENTER-TAPPED THIN-FILM HEADS FEATURES • Operates on +5 V and +12 V Power Supplies • Programmable Write-Current Source • TTL-Compatible Control Lines • W rite-Unsafe Detection Circuitry • Low Input Noise |
OCR Scan | ||||
| Power Connection Systems Safety Shroud CONNECTOR | Power Connection Systems Safety Shroud CONNECTOR Positronic Industries connectpositronic.com Safety Shrouded Connector to Prevent Unsafe Exposure to High Energy Circuits * Size 12 Power Contacts * Large Surface Area Mating System * Discriminating Locking System |