Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRISIL SM Search Results

    Documents mentioning TRISIL SM

    Document Partial File Text Tags Type PDF
    smthbt200
    SMTHBT200 TRISIL FOR LINE CARD PROTECTION… FEATURES BIDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT : - IPP = 75 A, 10/1000 µs. HOLDING CURRENT = 150 mA min BREAKDOWN VOLTAGE = 200 V min. BREAKOVER VOLTAGE = 290 V max. SOD 15 (Plastic) DESCRIPTION
    Original PDF
    trisil
    TPUxx/SMTHDTxx TRISIL DISCRETE SOLUTION FOR ISDN PROTECTION… FEATURES . UNDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT : IPP = 75 A , 10/1000 µs. HOLDING CURRENT = 150mA. BREAKDOWN VOLTAGE: TPU58/SMTHDT58 = 58V. TPU80/SMTHDT80 = 80V. TPU120/SMTHDT120 = 120V.
    Original PDF
    smthdt58
    SMTHDTxx ® Application Specific Discretes TRISIL TM A.S.D. DISCRETE SOLUTION FOR ISDN PROTECTION FEATURES UNDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT: IPP = 75 A , 10/1000 µs. HOLDING CURRENT = 150mA. BREAKDOWN VOLTAGE: SMTHDT58 = 58V. SMTHDT80 = 80V.
    Original PDF
    crowbar
    SMP100-xxx  COMMUNICATION EQUIPMENT PROTECTION: TRISIL TM FEATURES BIDIRECTIONAL CROWBAR PROTECTION VOLTAGE RANGE : FROM 8V to 270V REPETITIVE PEAK PULSE CURRENT: IPP = 100 A (10/1000 µs) HOLDING CURRENT: IH = 150mA or 225mA LOW LEAKAGE CURRENT: IR = 2 µA max
    Original PDF
    smthdt58
    SMTHDT58 TRISIL FOR SLIC PROTECTION… FEATURES CROWBAR PROTECTION. ASYMETRICAL TRANSIENT SUPPRESSOR PEAK PULSE CURRENT : - IPP = 75 A, 10/1000 µs. HOLDING CURRENT = 150 mA min BREAKDOWN VOLTAGE = 58 V. BREAKOVER VOLTAGE = 80V max. SOD 15 (Plastic)
    Original PDF
    SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™
    SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA min.
    Original PDF
    SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™
    SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection. Voltage range from 62V to 270V. Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max Holding current: IH = 150 mA min.
    Original PDF
    smtpb
    SMTPB SERIES TRISIL… FEATURES BIDIRECTIONAL CROWBAR PROTECTION. BREAKDOWN VOLTAGE RANGE: From 62 V To 270 V. HOLDING CURRENT = 150 mA min PEAK PULSE CURRENT : IPP = 90 A, 10/1000 µs. SOD 15 DESCRIPTION (Plastic) The SMTPBxx series has been designed to
    Original PDF
    smp80mc-270
    SMP80MC-270 ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage: 270V Low VBO / VR ratio Micro capacitance 15pF typ @ 50V Low leakage current : IR = 2µA max Holding current: IH = 150 mA min
    Original PDF
    SMP30-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™
    SMP30-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 12pF to 20pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA min.
    Original PDF
    SMP100MC-xxx ® TELECOM EQUIPMENT PROTECTION:
    SMP100MC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 65V to 270V Low VBO / VR ratio Micro capacitance from 20 to 30pF typ @ 50V Low leakage current : IR = 2µA max
    Original PDF
    SMTPAxxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™
    SMTPAxxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA Min.
    Original PDF
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION:
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 8V to 262V Low capacitance from 30 pF to 45pF typ @ 50V Low leakage current : IR = 2 µA max Holding current: IH = 150 mA min
    Original PDF
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION:
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 8V to 262V Low capacitance from 30 pF to 45pF typ @ 50V Low leakage current : IR = 2 µA max Holding current: IH = 150 mA min
    Original PDF
    trisil
    SMP100LC Trisil™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage range from 8 V to 400 V ■ Low capacitance from 20 pF to 45 pF @ 2 V ■ Low leakage current: IR = 2 µA max ■ Holding current: IH = 150 mA min.
    Original PDF
    smp50
    SMP50 / SMPTA / TPA Trisil™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage range from 62 V to 320 V ■ Low capacitance from 12 pF to 20 pF @ 50 V ■ Low leakage current : IR = 2 µA max ■ Holding current: IH = 150 mA min
    Original PDF
    smp100mc
    SMP100MC ® TRISIL™ FOR TELECOM EQUIPMENT PROTECTION FEATURES ■ Bidirectional crowbar protection ■ Voltage: range from 140V to 400V ■ Low VBO / VR ratio ■ Micro capacitance from 15pF to 30pF @ 50V ■ Low leakage current : IR = 2µA max ■ Holding current: IH = 150 mA min
    Original PDF
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION:
    SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES n n n n n Bidirectional crowbar protection Low capacitance : from C = 30 pF typ @ 50V Low leakage current : IR = 2 µA max Repetitive peak pulse current : IPP = 100 A (10/1000µs) Holding current: IH = 150 mA
    Original PDF
    smp80mc
    SMP80MC ® TRISIL™ FOR TELECOM EQUIPMENT PROTECTION FEATURES ■ Bidirectional crowbar protection ■ Voltage: range from 120V to 270V ■ Low VBO / VR ratio ■ Micro capacitance equal to 12pF @ 50V ■ Low leakage current : IR = 2µA max ■ Holding current: IH = 150 mA min
    Original PDF
    PROTECTION CIRCUITS TRISILTM HIGH ENERGY CROWBAR
    PROTECTION CIRCUITS TRISILTM HIGH ENERGY CROWBAR DEVICES SMA SMB SMD TRISIL Ipp 10/1000 µs 30 Amps ♦ 50 Amps 75 Amps 100 Amps VRM @ IRM VBR @ IR VBO @ IBO IH C Part Number max max max min max (V) (µA) Bidirectional (V) (mA) (V) (mA) (mA) (pF) 56 61 90
    Original PDF
    smp80mc
    SMP80MC TRISIL™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage: range from 120 V to 320 V ■ Low VBO / VR ratio ■ Micro capacitance equal to 12 pF @ 50 V ■ Low leakage current : IR = 2 µA max ■ Holding current: IH = 150 mA min
    Original PDF