| smthbt200 | SMTHBT200 TRISIL FOR LINE CARD PROTECTION… FEATURES BIDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT : - IPP = 75 A, 10/1000 µs. HOLDING CURRENT = 150 mA min BREAKDOWN VOLTAGE = 200 V min. BREAKOVER VOLTAGE = 290 V max. SOD 15 (Plastic) DESCRIPTION |
Original | ||||
| trisil | TPUxx/SMTHDTxx TRISIL DISCRETE SOLUTION FOR ISDN PROTECTION… FEATURES . UNDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT : IPP = 75 A , 10/1000 µs. HOLDING CURRENT = 150mA. BREAKDOWN VOLTAGE: TPU58/SMTHDT58 = 58V. TPU80/SMTHDT80 = 80V. TPU120/SMTHDT120 = 120V. |
Original | ||||
| smthdt58 | SMTHDTxx ® Application Specific Discretes TRISIL TM A.S.D. DISCRETE SOLUTION FOR ISDN PROTECTION FEATURES UNDIRECTIONAL CROWBAR PROTECTION. PEAK PULSE CURRENT: IPP = 75 A , 10/1000 µs. HOLDING CURRENT = 150mA. BREAKDOWN VOLTAGE: SMTHDT58 = 58V. SMTHDT80 = 80V. |
Original | ||||
| crowbar | SMP100-xxx COMMUNICATION EQUIPMENT PROTECTION: TRISIL TM FEATURES BIDIRECTIONAL CROWBAR PROTECTION VOLTAGE RANGE : FROM 8V to 270V REPETITIVE PEAK PULSE CURRENT: IPP = 100 A (10/1000 µs) HOLDING CURRENT: IH = 150mA or 225mA LOW LEAKAGE CURRENT: IR = 2 µA max |
Original | ||||
| smthdt58 | SMTHDT58 TRISIL FOR SLIC PROTECTION… FEATURES CROWBAR PROTECTION. ASYMETRICAL TRANSIENT SUPPRESSOR PEAK PULSE CURRENT : - IPP = 75 A, 10/1000 µs. HOLDING CURRENT = 150 mA min BREAKDOWN VOLTAGE = 58 V. BREAKOVER VOLTAGE = 80V max. SOD 15 (Plastic) |
Original | ||||
| SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ | SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA min. |
Original | ||||
| SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ | SMP50-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection. Voltage range from 62V to 270V. Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max Holding current: IH = 150 mA min. |
Original | ||||
| smtpb | SMTPB SERIES TRISIL… FEATURES BIDIRECTIONAL CROWBAR PROTECTION. BREAKDOWN VOLTAGE RANGE: From 62 V To 270 V. HOLDING CURRENT = 150 mA min PEAK PULSE CURRENT : IPP = 90 A, 10/1000 µs. SOD 15 DESCRIPTION (Plastic) The SMTPBxx series has been designed to |
Original | ||||
| smp80mc-270 | SMP80MC-270 ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage: 270V Low VBO / VR ratio Micro capacitance 15pF typ @ 50V Low leakage current : IR = 2µA max Holding current: IH = 150 mA min |
Original | ||||
| SMP30-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ | SMP30-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 12pF to 20pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA min. |
Original | ||||
| SMP100MC-xxx ® TELECOM EQUIPMENT PROTECTION: | SMP100MC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 65V to 270V Low VBO / VR ratio Micro capacitance from 20 to 30pF typ @ 50V Low leakage current : IR = 2µA max |
Original | ||||
| SMTPAxxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ | SMTPAxxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 62V to 270V Low capacitance from 15pF to 30pF typ.@ 50V Low leakage current: IR = 2µA max. Holding current: IH = 150 mA Min. |
Original | ||||
| SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: | SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 8V to 262V Low capacitance from 30 pF to 45pF typ @ 50V Low leakage current : IR = 2 µA max Holding current: IH = 150 mA min |
Original | ||||
| SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: | SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES ■ Bidirectional crowbar protection Voltage range from 8V to 262V Low capacitance from 30 pF to 45pF typ @ 50V Low leakage current : IR = 2 µA max Holding current: IH = 150 mA min |
Original | ||||
|
|
||||||
| trisil | SMP100LC Trisil™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage range from 8 V to 400 V ■ Low capacitance from 20 pF to 45 pF @ 2 V ■ Low leakage current: IR = 2 µA max ■ Holding current: IH = 150 mA min. |
Original | ||||
| smp50 | SMP50 / SMPTA / TPA Trisil™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage range from 62 V to 320 V ■ Low capacitance from 12 pF to 20 pF @ 50 V ■ Low leakage current : IR = 2 µA max ■ Holding current: IH = 150 mA min |
Original | ||||
| smp100mc | SMP100MC ® TRISIL™ FOR TELECOM EQUIPMENT PROTECTION FEATURES ■ Bidirectional crowbar protection ■ Voltage: range from 140V to 400V ■ Low VBO / VR ratio ■ Micro capacitance from 15pF to 30pF @ 50V ■ Low leakage current : IR = 2µA max ■ Holding current: IH = 150 mA min |
Original | ||||
| SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: | SMP100LC-xxx ® TELECOM EQUIPMENT PROTECTION: TRISIL™ FEATURES n n n n n Bidirectional crowbar protection Low capacitance : from C = 30 pF typ @ 50V Low leakage current : IR = 2 µA max Repetitive peak pulse current : IPP = 100 A (10/1000µs) Holding current: IH = 150 mA |
Original | ||||
| smp80mc | SMP80MC ® TRISIL™ FOR TELECOM EQUIPMENT PROTECTION FEATURES ■ Bidirectional crowbar protection ■ Voltage: range from 120V to 270V ■ Low VBO / VR ratio ■ Micro capacitance equal to 12pF @ 50V ■ Low leakage current : IR = 2µA max ■ Holding current: IH = 150 mA min |
Original | ||||
| PROTECTION CIRCUITS TRISILTM HIGH ENERGY CROWBAR | PROTECTION CIRCUITS TRISILTM HIGH ENERGY CROWBAR DEVICES SMA SMB SMD TRISIL Ipp 10/1000 µs 30 Amps ♦ 50 Amps 75 Amps 100 Amps VRM @ IRM VBR @ IR VBO @ IBO IH C Part Number max max max min max (V) (µA) Bidirectional (V) (mA) (V) (mA) (mA) (pF) 56 61 90 |
Original | ||||
| smp80mc | SMP80MC TRISIL™ for telecom equipment protection Features ■ Bidirectional crowbar protection ■ Voltage: range from 120 V to 320 V ■ Low VBO / VR ratio ■ Micro capacitance equal to 12 pF @ 50 V ■ Low leakage current : IR = 2 µA max ■ Holding current: IH = 150 mA min |