Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSFORMER ABB Search Results

    Documents mentioning TRANSFORMER ABB

    Document Partial File Text Tags Type PDF
    LAN DISCRETE TRANSFORMER MODULES Pulse Discrete
    LAN DISCRETE TRANSFORMER MODULES Pulse Discrete Transformer Modules Pulse offers comprehensive line of discrete LAN transformer modules. Pulse Modules 100/1000/10GBASE-T are optimized for all major LAN transceivers. All modules provide electrical circuit isolation that meets IEEE 802.3, while maintaining signal integrity
    Original PDF
    Technical reference manual Transformer protection
    Technical reference manual Transformer protection terminal RET 521*2.5 7HFKQLFDO UHIHUHQFH PDQXDO ProtectIT Transformer protection terminal RET 521*2.5 $ERXW WKLV PDQXDO DocID: 1MRK 504 036-UEN Issue date: December 2003 Revision: - © Copyright 2003 ABB. All rights reserved.
    Original PDF
    current transformer
    Pr o du ct 42 Bushing Current Transformer Low Voltage Instrument Transformer Multi-Ratio, Externally Mounted 25 through 60 Hertz Application Externally mounted bushing current transformers are designed for use on existing power transformers or circuit breakers for
    Original PDF
    Transformer protection terminal RET 521*2.1 1MRK
    Transformer protection terminal RET 521*2.1 1MRK 504 012-BEN Page 1 Issued May 1999 Changed since March 1999 Data subject to change without notice (SE960158) Features • Multiple function transformer protection terminal in a compact design - Overexcitation restraint with 5th harmonic
    Original PDF
    Product introduction Medium voltage voltage
    Product introduction Medium voltage voltage transformer JDZ23-10(3/6) Type designation Type code Designation Net weight J Voltage transformer 27 kg D Single phase Z Cast epoxy resin 23 Design sequence 10(3/6) Rated voltage Technical data Type Rated transformation ratio (kV)
    Original PDF
    001-ben
    JL » 1 1 n i p » Transformer protection terminal RET 521 1MRK 504 001-BEN Page 1 Issued June 1998 Changed since April 1998 Data subject to change without notice (SE960158) Features Multiple function transformer protection ter­ minal in a compact design
    OCR Scan PDF
    adm2485
    High Speed, Isolated RS-485 Transceiver with Integrated Transformer Driver ADM2485 FEATURES FUNCTIONAL BLOCK DIAGRAM VDD1 D1 VDD2 D2 OSC ADM2485 GALVANIC ISOLATION RTS TxD RxD DE OUT A B RE GND2 GND1 06021-001 Half-duplex, isolated RS-485 transceiver Integrated oscillator driver for external transformer
    Original PDF
    ralza
    Imo-No. INFORMATION RF 619-001 From/Date ASS Relays Reg. RFA, No\'ember 1988 Edition 4 E Page 743.5 1 Ultra High SpeedLine Protection type RALZA Unaffected by current transformer voltage transformer transients. saturation and capacitor Ultra high Spe-edof fault detection, typical 2-5 ms.
    Original PDF
    Type RCA Current Transformer 600 Volt, 10 kV BIL,
    Type RCA Current Transformer 600 Volt, 10 kV BIL, Indoor Product Bulletin 1VAP428841-DB Product Features • 600 Volt Indoor • 10 kV BIL • 25 through 400 Hertz • Primary Amperes 200-4000 Application The RCA current transformer is used as the source of current for
    Original PDF
    adm2485
    High Speed, Isolated RS-485 Transceiver with Integrated Transformer Driver ADM2485 FEATURES FUNCTIONAL BLOCK DIAGRAM VDD1 D1 VDD2 D2 OSC ADM2485 GALVANIC ISOLATION RTS TxD RxD DE OUT A B RE GND2 GND1 06021-001 Half-duplex, isolated RS-485 transceiver Integrated oscillator driver for external transformer
    Original PDF
    1vap428651-db
    Type SCG Current Transformer 600 Volt, 10 kV BIL, Indoor Product Bulletin 1VAP428651-DB Application The SCG current transformer is used as the source of current for relaying and metering. It is available in five internal window diameter sizes and dual and multi-ratio designs are available upon request.
    Original PDF
    29lpt1002t
    KENT MODULAR ELECTRONICS Ltd. Legacy Pixel Transformer 29LPT1002T User Manual Contents Page Overview… 3 Specifications… 4
    Original PDF
    Pr o du ct 42 Type KON-11 Current Transformer
    Pr o du ct 42 Type KON-11 Current Transformer Medium Voltage Instrument Transformer NSV 13.8 kV Outdoor, 110 kV BIL Primary Amperes 10-800 25 through 60 Hertz Application Type KON-11 current transformers are designed for outdoor 15 kV metering applications. Features include a compact size,
    Original PDF
    Direct Link 1128 Applications & Cases
    Direct Link 1128 Applications & Cases Miniaturisierte Current-Sense-Transformer Juni 2008 Verlustlose Strommessung Current-Sense-Transformer (CST) werden für die Regelung, Schutzbeschaltung oder Lasterkennung in Stromversorgungen eingesetzt. EPCOS hat zwei neue CSTBaureihen entwickelt, die dank ihrer platzsparenden SMTAusführung besonders für kompakte DC/DC-Konverter geeignet sind. Bei
    Original PDF
    Itansformer Questions and Answers 1. What is a
    Itansformer Questions and Answers 1. What is a transformer and how does it work? A transformer is an electrical appara­ tus designed to convert alternating cur­ rent from one voltage to another. It can be designed to “step up” or “step down” voltages and works on the magnetic
    OCR Scan PDF
    Type CSH Current Transformer 600 Volt, 10 kV BIL,
    Type CSH Current Transformer 600 Volt, 10 kV BIL, Indoor or Outdoor Product Bulletin 1VAP428141-DB Product Features • 600 Volt Indoor or Outdoor • 10 kV BIL • 25 - 60 Hertz • Primary Amperes 200-800 • Window Type Application The CSH is a miniature current transformer used for indoor and
    Original PDF
    3URWHFW,7 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7
    3URWHFW,7 7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 +79 1MRK 504 047-BEN Page 1 Issued: June 2004 Revision: Data subject to change without notice )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Multiple function transformer protection terminal in a compact design
    Original PDF