Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSFORMER 220 VOLT Search Results

    Documents mentioning TRANSFORMER 220 VOLT

    Document Partial File Text Tags Type PDF
    transformer
    General Accessories Transformers Type ST Transformer type ST 012 Where equipment needs a power supply differing from that of the mains, a transformer can be used to give a suitable alternating voltage. Primary circuit Secondary circuit 220 or 380 VAC. 24 VAC, 0.5 A
    Original PDF
    ADSL CPE TRANSFORMER For Centillium Palladia and
    ADSL CPE TRANSFORMER For Centillium Palladia and StreetFighter Chipsets ADSL CPE Transformer for ANNEX A Approved for use with Centillium’s Palladia 220 and StreetFighter 100 chipsets EN60950 Supplementary Isolation Compliant - 250Vrms Electrical Specifications @ 25°C — Operating Temperature -40°C to 85°C
    Original PDF
    bul38d
    BUL38D !!!!!!!! !!!!!!NPN POWER TRANSISTORS ! FEATURES WIDE SOA HIGH SPEED SWITCHING HIGH VOLTAGE CAPABILITY APPLICATION FLUORESCENT LAMP ELECTRONIC BALLAST ELECTRONIC TRANSFORMER  SWITCH MODE POWER SUPPLY Absolute Maximum Ratings Tc=25qC TO-220 PARAMETER
    Original PDF
    stc13005
    STC13005 !!!!!!!!! FEATURES !!!!!!NPN POWER TRANSISTORS ! HIGH VOLTAGE CAPABILITY APPLICATION  FLUORESCENT LAMP HIGH SPEED SWITCHING ELECTRONIC BALLAST WIDE SOA ELECTRONIC TRANSFORMER SWITCH MODE POWER SUPPLY Absolute Maximum Ratings Tc=25qC TO-220 PARAMETER
    Original PDF
    stc13003
    STC13003 !!!!!!!! FEATURES ! HIGH VOLTAGE CAPABILITY APPLICATION FLUORESCENT LAMP !!!!!!NPN POWER TRANSISTORS HIGH SPEED SWITCHING ELECTRONIC BALLAST WIDE SOA ELECTRONIC TRANSFORMER  Absolute Maximum Ratings Tc=25qC TO-220 PARAMETER SYMBOL VALUE UNIT Collector-Base Voltage
    Original PDF
    jt-16-a
    Jensen…The Worlds Finest Audio Transformers JT-16-A Microphone Input Transformer 1:2 STEP-UP FOR ULTRA-LOW NOISE AMPLIFIERS • Our highest performance mic input transformer Wide bandwidth: -3 dB at 0.45 Hz and 220 kHz Excellent time domain performance: DLP +1° typical
    Original PDF
    150va
    150VA Auto Transformer Specification R.S Stock Number 504-189 Manufacturer Part Number 10-5834 Nominal Input Voltage 0-220-230-240v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 140mA (max.) Nominal Output 115V @ 150VA Winding Resistance 10.8  +/- 15% @ 20.C
    Original PDF
    100va
    100VA Auto Transformer Specification R.S Stock Number 504-183 Manufacturer Part Number 10-5833 Nominal Input Voltage 0-220-230-240v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 80mA (max.) Nominal Output 115V @ 100VA Winding Resistance 17.7  +/- 15% @ 20.C
    Original PDF
    1000va
    1000VA Auto Transformer Specification R.S Stock Number 504-206 Manufacturer Part Number 10-5837 Nominal Input Voltage 0-220-230-240v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 600mA (max.) Nominal Output 115V @ 1000VA Winding Resistance 0.46  +/- 15% @ 20.C
    Original PDF
    500va
    500VA Auto Transformer Specification R.S Stock Number 504-195 Manufacturer Part number 10-5836 Nominal Input Voltage 0-220-230-240v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 250mA (max.) Nominal Output 115V @ 500VA Winding Resistance 1.88  +/- 15% @ 20.C
    Original PDF
    250va
    250VA Auto Transformer Specification R.S Stock Number 504-199 Manufacturer Part Number 10-5835 Input Voltage 0-220-230-240v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 150mA (max.) Nominal Output 115V @ 250VA Winding Resistance 5.6  +/- 15% @ 20.C
    Original PDF
    LAMBDAA An Invensys company Input voltage
    LAMBDAA An Invensys company Input voltage 100-120-220-230-240 VAC range ± 10% Voltage selection on input transformer Frequency 47 to 63Hz OUTPUT Power (natural convection) 15 at 100W Adjustment voltage range + 5% minimum Line regulation ± 0.15% Load regulation
    OCR Scan PDF
    Series H INPUT Input voltage range
    Series H INPUT Input voltage range 100-120-220-230-240 VAC ± 10% Voltage selection on input transformer Frequency 47 to 63Hz OUTPUT 15-100 WATTS POWER SUPPLY AC/DC SINGLE, DUAL OR TRIPLE OUTPUT Low cost Power (natural convection) 15 at 100W Adjustment voltage range
    Original PDF
    zr2431
    Design Note 38 Issue 1 June 1996 The ZR2431 Low Voltage Shunt Regulator in SMPS Control Loops D1 +ve +ve OPT1 R5 * Note 1 Input (From Converter Transformer) R1 220 R3 160k C1 22nF IC1 ZR2431 Output C2 220uF (3.0V) R2 10k C4 * Note 1 C3 * Note 1 -ve R4 120k
    Original PDF
    pc20-220
    POWER TRANSFORMER PC20-220 (F) SERIES 1. CONFIGURATION & DIMENSIONS : W B 1 5 3 6 4 4.76 (0.188) B A-6 A-6 2 L A-6 A-6 1.0414 (0.041) H PCB Pattern PC Terminal (Plug-in mounting) TYPE PC 6 PINS UNIT : mm (inch) A-6 SIZE (VA) 4.4 L W H WT. 6 PIN OPTIONAL BRACKET *
    Original PDF
    jt-11ssp-8ma
    JT-11SSP-8MA 1:1 CONFIGURATION LINE INPUT TRANSFORMER 1:1 SPLIT WINDING "REPEAT COIL" M M M M M Ideal for use with low input impedance circuits Wide bandwidth: !3 dB at 0.25 Hz and 220 kHz Recommended for levels up to +23 dBu at 20 Hz Insertion loss only 1.3 dB in 600 S to 600 S application
    Original PDF
    auxiliary transformer
    Voltage and Auxiliary Transformer Fuse Links British Standard VT Fuse Links. A range of voltage transformer primary Fuse Links to BS2692-1 and IEC60282-1. Wide range of ratings from 1 kV to 36 kV. 3.15 Amp industry standard current ratings. CAV range with ratings from 3.6kV to 38kV.
    Original PDF
    Power Isolation Transformers SM Industrial Grade
    Power Isolation Transformers SM Industrial Grade Step-Up or Step-Down Transformers Signal’s DU and SU transformers have been designed to provide a multitude of step-up or step-down voltages to accommodate various input voltages available throughout the world.
    Original PDF
    SSR Glossary Glossary Terms Circuit Photocoupler
    SSR Glossary Glossary Terms Circuit Photocoupler functions Phototriac coupler Zero cross circuit (Refer to page 4.) Input Output Characteristics Others Meaning Transfers the input signal while insulating inputs and outputs. A circuit which starts operation with the AC load voltage at close to zero-phase.
    Original PDF