| thermopile | Thermopile Infrared Sensor TP336 Features The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545m (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 |
Original | ||||
| otc-239 | OTC-239 THERMOPILE INFRARED SENSOR Date : Oct. 10, 2000 Features The thermopile sensor consists of a series of 44 thermoelements, forming a sensitive area of 0.5*0.5 mm2. The sensor is hermetically sealed into a TO-18 metal housing, with optical filter. This standard filter allows measurements to |
Original | ||||
| thermopile | Thermopile Infrared Sensor OTC-239 Features The thermopile sensor consists of a series of 44 thermoelements, forming a sensitive area of 0.5*0.5 mm2. The sensor is hermetically sealed into a TO-18 metal housing, with optical filter. This standard filter allows measurements to be made in the spectral range above 5m wavelength. |
Original | ||||
| thermopile | Thermopile Infrared Sensor OTC-238 Features The thermopile sensor consists of a series of 44 thermoelements, forming a sensitive area of 0.5*0.5 mm2. The sensor is hermetically sealed into a TO-18 metal housing, with optical filter. This standard filter allows measurements to be made in the spectral range above 5m wavelength. |
Original | ||||
| M. K. JUCHHEIM GmbH & Co Postadresse: 36035 | M. K. JUCHHEIM GmbH & Co Postadresse: 36035 Fulda, Germany Hausadresse: Moltkestraße 1 3 - 3 1 36039 Fulda, Germany Telefon (0661) 6003-7 24 Telefax (0661) 6003-601 Teletex 6619726 (JUMP) MESS- UND REGELTECHNIK Typenblatt 90.1003, Seite 1/2 Einschraub-Thermoelemente |
OCR Scan | ||||
| temperaturregler | PID -Regler PID - Regler T48 l l l l l l l PID Temperaturregler im 48 x 48 mm Format Temperaturerfassung über Thermoelemente oder PT100 3 Ausgänge wahlweise Relais oder Solid State Relais - Treiber für 1 - 2 Regelausgänge und 1 - 2 Alarmausgänge, Triac |
Original | ||||
| Temperature measuring amplifier 1-channel | Temperature measuring amplifier 1-channel IM34-12Ex-CRi/K63 The temperature measuring amplifier IM34-12EX-CRI/K63 is designed to evaluate the temperature-dependent variations of resistance temperature detectors, thermoelements or low voltages and to output them as temperature-linear current signals between 0/4…20 |
Original | ||||
| thermopile | THERMOPILE Part No : 80-02-00010 Type : TP336A ▓ Features The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545μm (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5μ |
Original | ||||
| tp337a | THERMOPILE Part No : 80-02-00013 Type : TP337A ▓ Features The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545μm (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5μ |
Original | ||||
| mcr-fl-d-t-2sp-24 | MCR-FL-D-T-2SP-24 MCR-FL-D-T-2SP-230 für Thermoelemente, Messwiderstände, Widerstandsthermometer und Sensoren im mV-Bereich mit 2 Grenzwerten deutsch Prozess-Steuergerät for thermocouples measuring resistors resistance thermometers sensors im mV range with 2 alarms |
Original | ||||
| kl3311 | Betriebsanleitung zu KL3311, KL3312, KL3314 und KL3302 Ein-, zwei- und vierkanalige Analog-Eingangsklemmen für Thermoelemente Version: 3.4 Datum: 19.05.2008 Inhaltsverzeichnis Inhaltsverzeichnis 1. Vorwort Hinweise zur Dokumentation Sicherheitshinweise 1 |
Original | ||||
| termopar j | Codix 532 für Thermoelement-Sensoren J, K und N deutsch Digitalanzeige for Thermoelectric couple sensors J, K and N english Digital display Visualizador digital para Sondas con termopar J,K y N Visualizzatore digitale per Sonde a termocoppia J,K e N español |
Original | ||||
| thermopile | Thermopile Infrared Sensor TP337 Features The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545m (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 |
Original | ||||
| thermopile | OTC-237 THERMOPILE INFRARED SENSOR Date : Oct. 10, 2000 Features The thermopile sensor consists of a series of 44 thermoelements, forming a sensitive area of 0.5*0.5 mm2. The sensor is hermetically sealed into a TO-5 metal housing, with optical filter. This standard filter allows measurements to |
Original | ||||
|
|
||||||
| thermopile | Thermopile Infrared Sensor TP338 Features The thermopile sensor consists of a series of 116 thermoelements, forming a sensitive region size of 545m (diameter). The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 |
Original | ||||