THERMOCOUPLES Search Results
THERMOCOUPLES Result Highlights (1)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TIPD109 | Texas Instruments | Simple Thermocouple Measurement Solution Reference Design, <1°C Accurate |
|
Documents mentioning THERMOCOUPLES
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| DSCA47 Linearized Thermocouple Input Signal | DSCA47 Linearized Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized, and converted |
Original | ||||
| iso120 | ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION |
Original | ||||
| ISO122 Precision Lowest Cost ISOLATION AMPLIFIER | ISO122 Precision Lowest Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● 100% TESTED FOR HIGH-VOLTAGE BREAKDOWN ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator, Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation |
Original | ||||
| SCM7B47 Isolated Linearized Thermocouple Input | SCM7B47 Isolated Linearized Thermocouple Input Modules FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B AND N THERMOCOUPLES SCM7B47 modules accept a single channel of input from Type J, K, T, E, R, S, B, or N thermocouples. The signal is filtered, isolated, amplified, linearized, and converted |
Original | ||||
| Programmable Intrinsically Safe Loop-Powered | Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I |
Original | ||||
| scxi-1100 | Application Note 056 How to Use Thermocouples with an SCXI-1100 Module This application note describes how to set up and use the SCXI-1100 with thermocouples. It also describes example programs that use the SCXI-1100 to make thermocouple measurements. These example programs are included on the SCXI Application Examples disk included in the |
Original | ||||
| iso120 | ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION |
Original | ||||
| scxi-1120 | SCXI-1120, SCXI-1120D 8-Channel Isolation Amplifiers SCXI-1120, SCXI-1120D Isolated signal conditioning for Thermocouples Millivolt and volt inputs 4-20 mA or 0-20 mA inputs Isolates, amplifies, and multiplexes 8 channels 250 Vrms working isolation per channel |
Original | ||||
| thermocouple amplifier | SCXI 32-Channel Thermocouple Amplifier SCXI-1102 SCXI-1102 Features 32 differential channels Low-noise signal conditioning for: Thermocouples Low-bandwidth millivolt and volt signals 4-20 mA or 0-20 mA inputs Lowpass noise filters on every channel Programmable instrumentation amplifier |
Original | ||||
| ina102 | ® INA102 Low Power INSTRUMENTATION AMPLIFIER FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 750µA max ● AMPLIFICATION OF SIGNALS FROM SOURCES SUCH AS: Strain Gages (Weigh Scale Applications) Thermocouples Bridge Transducers ● REMOTE TRANSDUCER AMPLIFIER |
Original | ||||
| ad596 | a FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation – 10 mV/؇C Temperature Setpoint Operation – ON/OFF Programmable Switching Hysteresis High Impedance Differential Input |
Original | ||||
| Application Note 28 February 1988 Thermocouple | Application Note 28 February 1988 Thermocouple Measurement Jim Williams Introduction Thermocouples in Perspective In 1822, Thomas Seebeck, an Estonian physician, accidentally joined semicircular pieces of bismuth and copper (Figure 1) while studying thermal effects on galvanic arrangements. A nearby compass indicated a magnetic disturbance. Seebeck experimented repeatedly with different |
Original | ||||
| MINI MCR-SL-TC-UI(-NC) Configurable Temperature | MINI MCR-SL-TC-UI(-NC) Configurable Temperature Transducer for Type J and K Thermocouples Data Sheet 11/2004 Product Description Features The MINI MCR-SL-TC-UI(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of type J and K |
Original | ||||
| lt1025 | _____________________ LT1025 r r u n m te c h n o lo g y Micropower Thermocouple Cold Junction Compensator F€ATUA€S D C S C R IP T IO n ■ 80iiA Supply Current 4V to 36V Operation 0.5°C Initial Accuracy (A Version) Compatible with Standard Thermocouples |
OCR Scan | ||||
|
|
||||||
| signal conditioners | Signal Conditioners Temperature Transducer Signal Conditioners -IN -A LM +ALM V+ COM » VO FB AD594/AD595 Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-In Ice Point Compensation |
OCR Scan | ||||
| ► ANALOG DEVICES 6 Channel Scanning Digital | ► ANALOG DEVICES 6 Channel Scanning Digital Thermometer FEA TUR ES Automatic Scan of 6 Thermocouples (TC's) Manual Selection of Individual TC's External Channel Selection by BCD Code J, K, or T Thermocouple °C or °F: Readout Self Contained Linearization |
OCR Scan | ||||
| scxi-1121 | SCXI-1121 SCXI 4-Channel Isolation Amplifier with Excitation SCXI-1121 Isolated signal conditioning for Strain gauges RTDs Thermistors Millivolt and volt inputs 4-20 mA or 0-20 mA (with resistor kit) Thermocouples 4 isolated current or voltage excitation channels |
Original | ||||
| thermocouple | FP0 Thermocouple Modules FP0-TC4 FP0-TC8 The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user friendly temperature acquisition using standard thermocouples with a high precision. - TC inputs: 4ch and 8ch type The temperature of up to 24 channels can be controlled |
Original | ||||
| ANALOG DEVICES FEATURES Low Cost Operates w ith | ANALOG DEVICES FEATURES Low Cost Operates w ith Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice Point Compensation Tem perature Proportional Operation - 1 0 m V /°C Tem perature Setpoint Operation - O N /O FF Programmable Switching Hysteresis |
OCR Scan | ||||
| Micropower Thermocouple Cold Junction Compensator | Micropower Thermocouple Cold Junction Compensator A N A LO G ► D E V IC E S ri-s - X .r ' : -, -?■*# - f r s K ^ s g l FEATURES 80|jlA Supply Current 4V to 36V Operation 0.5°C Typical Initial Accuracy Compatible with Standard Thermocouples (E. J, K, R, S. T) |
OCR Scan | ||||
| max31855 | 19-5793; Rev 0; 3/11 MAX31855 Cold-Junction Compensated Thermocouple-to-Digital Converter General Description The MAX31855 performs cold-junction compensation and digitizes the signal from a K, J, N, T, or E type thermocouple. (Contact the factory for S and R type thermocouples.) The data is output in a signed 14-bit, SPI™compatible, read-only format. This converter resolves |
Original | ||||
| ISO120 ISO121 Precision Low Cost ISOLATION | ISO120 ISO121 Precision Low Cost ISOLATION AMPLIFIER FEATURES APPLICATIONS ● INDUSTRIAL PROCESS CONTROL: Transducer Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4mA to 20mA Loop Isolation ● GROUND LOOP ELIMINATION |
Original | ||||