Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOCOUPLE TYPE Search Results

    THERMOCOUPLE TYPE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-059FTYPEMM-025
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft PDF
    CO-059FTYPEMM-010
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft PDF
    CO-059FTYPEMM-050
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft PDF
    CO-059FTYPEMM-003
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft PDF
    CO-059FTYPEMM-006
    Amphenol Cables on Demand Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft PDF
    SF Impression Pixel

    THERMOCOUPLE TYPE Price and Stock

    Smiths Interconnect

    Smiths Interconnect THERMOCOUPLE PROBE (TYPE K) RED/YELLOW

    Contact Probes WIRED PROBE
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Mouser Electronics THERMOCOUPLE PROBE (TYPE K) RED/YELLOW 152
    • 1 $97.98
    • 10 $83.27
    • 100 $75.30
    • 1000 $75.30
    • 10000 $75.30
    Buy Now

    Smiths Interconnect THERMOCOUPLE PROBE (TYPE T)

    Contact Probes WIRED PROBE
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Mouser Electronics THERMOCOUPLE PROBE (TYPE T) 32
    • 1 $133.05
    • 10 $114.57
    • 100 $108.81
    • 1000 $108.81
    • 10000 $108.81
    Buy Now

    Documents mentioning THERMOCOUPLE TYPE

    Document Partial File Text Tags Type PDF
    INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES
    INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53 UL Instrumentation Cable Thermocouple Extension Cables and Thermocouple Wire — Overview Construction Thermocouple Extension Cable Conductor material determined by the thermocouple extension wire type. FEP
    Original PDF
    5b47
    Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates aisolated and protected precision output of 0 to
    Original PDF
    thermocouple
    Thermocouple Probe The Thermocouple Probe is an ungrounded, thermally conductive probe used for the measurement Temperature Range 100895 Thermocouple Probe Type T— up to 220° F .090 (2.29) Type K— up to 350° F .090 (2.29) Thermocouple Probe Design applications such as
    Original PDF
    type k thermocouple
    Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter
    Original PDF
    t01102
    T01102 001229 Thermocouple terminal blocks MTC 6 Thermocouple terminal blocks Spacing 6 mm .238" Compression clamp Entrelec's MTC 6 thermocouple terminal block provides an interface for connecting thermocouple wire with virtually no loss of signal integrity. The
    Original PDF
    ap4351
    ACTION PAK® AP4351 Thermocouple-Input, Field Configurable Isolator Provides Isolated, Linearized DC Output in Proportion to Thermocouple Input Description Benefits Field Configurable Thermocouple Types Linearized Outputs Wide-Ranging Zero and Span Adjustability (50%
    Original PDF
    IF L U K E I — ® Instruction Sheet 80TK
    IF L U K E I — ® Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy (% of reading + degrees) The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to
    OCR Scan PDF
    super mcj
    Thermocouple Input Super MCJ Analog Output, 1 mV per degree (SMP or OST Connector) SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog
    Original PDF
    3b47
    Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation.
    Original PDF
    thermocouples
    g THERMOCOUPLES & THERMOCOUPLE WIRE THERMOCOUPLE SELECTION Type E Nickel-Chromium vs. Copper-Nickel (Chromel † - Constantan) This thermocouple develops the highest EMF/°C or °F of any of the thermocouples listed here. It is used in inert, oxidizing, or
    Original PDF
    thermocouple connectors
    THERMOCOUPLE CONNECTORS & ACCESSORIES THERMOCOUPLE CONNECTORS & ACCESSORIES MINIATURE SOCKET, TWIN CONTACT Types J, K, T, N, E, R/S & COPPER THERMOCOUPLE CONNECTORS MINIATURE, RECTANGULAR, FASCIA SOCKETS Types J, K, T, N, E, R/S & COPPER Type J Type K Type T
    Original PDF
    Han® Thermocouple Contents Han® Thermocouple…
    Han® Thermocouple Contents Han® Thermocouple… Page 41.02 ­Thermo-­couple 41 . 01 Han® Thermocouple Features Technical characteristics • Connector for temperature measurement conductors - Suitable for injection moulding machines
    Original PDF
    es1a
    Non-contact Temperature Sensor No Power Supply Required Replaces K-type Thermocouple without Modification No Power Supply Required: The ES1A has electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple input terminal of the Temperature
    Original PDF
    DSCA47 Linearized Thermocouple Input Signal
    DSCA47 Linearized Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized, and converted
    Original PDF
    SCT1P37 Thermocouple Input Transmitters FEATURES
    SCT1P37 Thermocouple Input Transmitters FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each SCT1P37 thermocouple input transmitter provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a
    Original PDF
    Thermocouple Amplifiers Features: ■
    Thermocouple Amplifiers Features: ■ Cost-effective solution ■ Compact size ■ Accepts thermocouple types J,K,T,E ■ Span and zero user adjustable ■ Broad input temperature range from lower to maximum thermocouple temperature ■ 24 VDC powered (12VDC option)
    OCR Scan PDF
    DSCA37 Thermocouple Input Signal Conditioners
    DSCA37 Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA37 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a high
    Original PDF
    max873
    Maxim > App Notes > TEMPERATURE SENSORS and THERMAL MANAGEMENT VOLTAGE REFERENCES Keywords: MAX873, REF02, REF01, thermocouple compensation, thermocouple references, thermocouple voltage references Nov 01, 2000 APPLICATION NOTE 430 Voltage Reference Compensates Reference Junction
    Original PDF
    Thermocouple Measurement Converter to 4/20mA
    Thermocouple Measurement Converter to 4/20mA Diagrams Loop resistance Reference Table for Type K Thermocouple Loop operating conditions Ordering Data for TS 35 for TS 32 L j Temperature of Thermocouple Technical Data DC -200 -5891 10 20 -100 -3553 4095 8137
    OCR Scan PDF
    + – Revised Thermocouple Reference Tables J TYPE
    + – Revised Thermocouple Reference Tables J TYPE Reference Tables N.I.S.T. Monograph 175 Revised to ITS-90 °C -10 -9 -8 -7 -6 -5 -4 Thermocouple Grade Iron vs. Copper-Nickel + – Extension Grade MAXIMUM TEMPERATURE RANGE Thermocouple Grade 32 to 1382°F
    Original PDF