THERMOCOUPLE TYPE Search Results
THERMOCOUPLE TYPE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-059FTYPEMM-025 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft | |||
| CO-059FTYPEMM-010 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft | |||
| CO-059FTYPEMM-050 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft | |||
| CO-059FTYPEMM-003 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft | |||
| CO-059FTYPEMM-006 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft |
THERMOCOUPLE TYPE Price and Stock
Smiths Interconnect
Smiths Interconnect THERMOCOUPLE PROBE (TYPE K) RED/YELLOWContact Probes WIRED PROBE |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
THERMOCOUPLE PROBE (TYPE K) RED/YELLOW | 152 |
|
Buy Now | |||||||
Smiths Interconnect THERMOCOUPLE PROBE (TYPE T)Contact Probes WIRED PROBE |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
THERMOCOUPLE PROBE (TYPE T) | 32 |
|
Buy Now | |||||||
Documents mentioning THERMOCOUPLE TYPE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES | INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.53 UL Instrumentation Cable Thermocouple Extension Cables and Thermocouple Wire — Overview Construction Thermocouple Extension Cable Conductor material determined by the thermocouple extension wire type. FEP |
Original | ||||
| 5b47 | Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates aisolated and protected precision output of 0 to |
Original | ||||
| thermocouple | Thermocouple Probe The Thermocouple Probe is an ungrounded, thermally conductive probe used for the measurement Temperature Range 100895 Thermocouple Probe Type T— up to 220° F .090 (2.29) Type K— up to 350° F .090 (2.29) Thermocouple Probe Design applications such as |
Original | ||||
| type k thermocouple | Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter |
Original | ||||
| t01102 | T01102 001229 Thermocouple terminal blocks MTC 6 Thermocouple terminal blocks Spacing 6 mm .238" Compression clamp Entrelec's MTC 6 thermocouple terminal block provides an interface for connecting thermocouple wire with virtually no loss of signal integrity. The |
Original | ||||
| ap4351 | ACTION PAK® AP4351 Thermocouple-Input, Field Configurable Isolator Provides Isolated, Linearized DC Output in Proportion to Thermocouple Input Description Benefits Field Configurable Thermocouple Types Linearized Outputs Wide-Ranging Zero and Span Adjustability (50% |
Original | ||||
| IF L U K E I — ® Instruction Sheet 80TK | IF L U K E I — ® Instruction Sheet 80TK Thermocouple Module INTRODUCTION Range Accuracy (% of reading + degrees) The Fluke 80TK is a thermocouple converter for use with any Ktype thermocouple and a digital multimeter (DMM). The 80TK accepts the output of any K-type thermocouple and converts it to |
OCR Scan | ||||
| super mcj | Thermocouple Input Super MCJ Analog Output, 1 mV per degree (SMP or OST Connector) SMCJ-J, SMCJ-K, SMCJ-T INSTRUCTION SHEET M-2813 Thermocouple-to-Analog Connector GENERAL DESCRIPTION This is a Thermocouple to Analog Connector. It converts a thermocouple input signal (Type J, K, or T) to a linear, compensated, amplified analog |
Original | ||||
| 3b47 | Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation. |
Original | ||||
| thermocouples | g THERMOCOUPLES & THERMOCOUPLE WIRE THERMOCOUPLE SELECTION Type E Nickel-Chromium vs. Copper-Nickel (Chromel † - Constantan) This thermocouple develops the highest EMF/°C or °F of any of the thermocouples listed here. It is used in inert, oxidizing, or |
Original | ||||
| thermocouple connectors | THERMOCOUPLE CONNECTORS & ACCESSORIES THERMOCOUPLE CONNECTORS & ACCESSORIES MINIATURE SOCKET, TWIN CONTACT Types J, K, T, N, E, R/S & COPPER THERMOCOUPLE CONNECTORS MINIATURE, RECTANGULAR, FASCIA SOCKETS Types J, K, T, N, E, R/S & COPPER Type J Type K Type T |
Original | ||||
| Han® Thermocouple Contents Han® Thermocouple… | Han® Thermocouple Contents Han® Thermocouple… Page 41.02 Thermo-couple 41 . 01 Han® Thermocouple Features Technical characteristics • Connector for temperature measurement conductors - Suitable for injection moulding machines |
Original | ||||
| es1a | Non-contact Temperature Sensor No Power Supply Required Replaces K-type Thermocouple without Modification No Power Supply Required: The ES1A has electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple input terminal of the Temperature |
Original | ||||
| DSCA47 Linearized Thermocouple Input Signal | DSCA47 Linearized Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA47 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized, and converted |
Original | ||||
|
|
||||||
| SCT1P37 Thermocouple Input Transmitters FEATURES | SCT1P37 Thermocouple Input Transmitters FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each SCT1P37 thermocouple input transmitter provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a |
Original | ||||
| Thermocouple Amplifiers Features: ■ | Thermocouple Amplifiers Features: ■ Cost-effective solution ■ Compact size ■ Accepts thermocouple types J,K,T,E ■ Span and zero user adjustable ■ Broad input temperature range from lower to maximum thermocouple temperature ■ 24 VDC powered (12VDC option) |
OCR Scan | ||||
| DSCA37 Thermocouple Input Signal Conditioners | DSCA37 Thermocouple Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO TYPES J, K, T, E, R, S, B, AND N THERMOCOUPLES Each DSCA37 thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a high |
Original | ||||
| max873 | Maxim > App Notes > TEMPERATURE SENSORS and THERMAL MANAGEMENT VOLTAGE REFERENCES Keywords: MAX873, REF02, REF01, thermocouple compensation, thermocouple references, thermocouple voltage references Nov 01, 2000 APPLICATION NOTE 430 Voltage Reference Compensates Reference Junction |
Original | ||||
| Thermocouple Measurement Converter to 4/20mA | Thermocouple Measurement Converter to 4/20mA Diagrams Loop resistance Reference Table for Type K Thermocouple Loop operating conditions Ordering Data for TS 35 for TS 32 L j Temperature of Thermocouple Technical Data DC -200 -5891 10 20 -100 -3553 4095 8137 |
OCR Scan | ||||
| + – Revised Thermocouple Reference Tables J TYPE | + – Revised Thermocouple Reference Tables J TYPE Reference Tables N.I.S.T. Monograph 175 Revised to ITS-90 °C -10 -9 -8 -7 -6 -5 -4 Thermocouple Grade Iron vs. Copper-Nickel + – Extension Grade MAXIMUM TEMPERATURE RANGE Thermocouple Grade 32 to 1382°F |
Original | ||||