Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LR42272 Search Results

    Documents mentioning LR42272

    Document Partial File Text Tags Type PDF
    q414
    ACTIONI/Q® Q414 & Q415 MODEL Protecting the Integrity of Industrial Process Signals RTD Input, Three-Wire Transmitter Provides Two DC Outputs in Proportion toTwo Pt100Ω RTD Temperature Inputs Benefits n Multi-Channel Design Provides Two (2) Threewire Transmitters in 1
    Original PDF
    action pak
    ACTION PAK® AP6380 Input, Isolated, Field Configurable Isolator Provides a Fully Isolated DC Output in Proportion to an AC Input Description Benefits Eliminates Ground Loops Field Configurable Input Ranges: 50mV to 200V AC, 5mA to 100mA AC The field configurable AP6380 signal conditioner offers wide ranging input capability for scaling, converting
    Original PDF
    g418-0001
    ULTRA SLIMPAK® G418-0001 RTD Input Field Configurable Isolator Provides an Isolated, Linearized DC Output in Proportion to an RTD Input Description Benefits The Ultra SlimPak G418 is a DIN rail mount, RTD input signal conditioner with 1800VDC isolation between input, output and power. The field configurable input and output offers flexible, wide
    Original PDF
    ap7500
    ACTION PAK® AP7500 & 7501 DC to Frequency Converters Provides a Field Selectable Frequency Output in Proportion to a DC Input Application Benefits Switch Selectable Output Range Adjustable Low End Cutout (0-10%) The AP7500 and AP7501 are useful in totalizing applications, where the total number of pulses counted
    Original PDF
    q500
    ACTIONI/Q® Q500 Loop-Powered, Multi-Channel Isolator Provides up to 4 Isolated DC Current Outputs in Proportion to the Input Currents Description Benefits Up to 4 Loop Isolators in a Single Package Prevents Ground Loops SnapLoc™ Plug-in Terminals The Q500 is a DIN rail mount, loop-powered isolator with single, dual or quad (4) channel capability.
    Original PDF
    ap1080
    ACTION PAK® AP1080 & AP1090 DC Input, Field Configurable Limit Alarms Provides Relay Contact Closures at a Preset DC Input Level Description Benefits Field Configurable Input Ranges for DC Voltage and Current Action Pak models AP1080 single setpoint and AP1090 dual setpoint limit alarms offer flexible,
    Original PDF
    g128-0001
    ULTRA SLIMPAK® G128-0001 Thermocouple Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset Temperature Input Level Description The Ultra Slim Pak G128 is a DIN rail mount, thermocouple input limit alarm with input terminal cold junction compensation (cjc), dual setpoints and two contact closure outputs. The field
    Original PDF
    g468-0001
    ULTRA SLIMPAK® G468-0001 AC Input Field Configurable Isolator Provides an Isolated DC Output in Proportion to an AC Input Description Benefits Eliminates Ground Loops Field Configurable Input Ranges: 50mV to 250VAC, 5mA to 5A AC Field Configurable Outputs:
    Original PDF
    g168
    ULTRA SLIMPAK® G168-0001 AC Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset AC Input Level Description Benefits Field Configurable Input Ranges The Ultra Slim Pak G168 is a DIN rail mount, DC powered, AC voltage or current input limit alarm
    Original PDF
    q108
    ACTIONI/Q® Q108 DC Input Limit Alarm Provides Relay Contact Closure at a Preset DC Input Level Description The ActionI/Q model Q108 is a DIN rail mount, DC voltage or current input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer
    Original PDF
    ULTRA SLIMPAK® G438 Potentiometer Input Field
    ULTRA SLIMPAK® G438 Potentiometer Input Field Configurable Signal Conditioner Provides a DC Output in Proportion to a Potentiometer Input Description Benefits Potentiometers from 100 Ohms to 100K Ohms Wide Ranging Zero & Span Adjustability Field Configurable Outputs: 0-5V,
    Original PDF
    q486
    ACTIONI/Q® Q486-0001 RTD, T/C, Ohm & mV Input Field Configurable Isolator Provides an Isolated DC Output in Proportion to the Temperature Signal Input Description Benefits The Q486 is a DIN rail mount, RTD, thermocouple, mV or Ohm input signal conditioner with 1800V
    Original PDF
    q466
    ACTIONI/Q® Q466 AC Input Field Configurable Isolator Provides an Isolated DC Output in Proportion to an AC Input Description Benefits Eliminates Ground Loops Field Configurable Input Ranges The Q466 is a DIN rail mount, AC input signal conditioner with 1800VDC isolation between input,
    Original PDF
    g408-0001
    ULTRA SLIMPAK® G408-0001 & G408-1001 DC Input Field Configurable Isolator Provides a Fully Isolated DC Output in Proportion to a DC Input Description Benefits Eliminates Ground Loops Field Configurable Input Ranges: 10mV to 100V, 1mA to 100mA Field Configurable Output
    Original PDF
    q404
    ACTIONI/Q® Q404-2/3/4 DC Powered DC Input Multi-Channel Isolator Q404-2 (2 inputs; 2 outputs) Q404-3 (1 input; 1 output; 24V Exc) Q404-4 (signal splitter: 1 input; 2 outputs) Multi-Channel Design 2000VAC Isolation High Density DIN Rail Mounting Description
    Original PDF
    g118-0002
    ULTRA SLIMPAK® G118-0002 RTD Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset RTD/Resistance Input Level Description Benefits The Ultra SlimPak G118 is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint
    Original PDF
    g108
    ULTRA SLIMPAK® G108 DC Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset DC Input Level Description Benefits The Ultra SlimPak G108 is a DIN rail mount, DC voltage or current input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer
    Original PDF
    ap9046
    ACTION PAK® AP9046 DC Output Power Supply Provides a Regulated 24VDC Output at up to 65mA Application Benefits Ideal for Two-Wire Transmitters Plug-in Installation The AP9046 is useful in any two-wire transmission application to power the current loop. The 24VDC
    Original PDF
    action pak
    ACTION PAK® AP4081 Bridge Input, Field Configurable Isolator Provides an Isolated, DC Output in Proportion to a Bridge/StrainGauge Input Description The Action Pak AP4081 is a bridge or strain-gauge input signal conditioner with 1500VDC isolation between
    Original PDF
    g478-0001
    ULTRA SLIMPAK® G478-0001 Frequency Input, Field Configurable Isolator Provides an Isolated DC Output in Proportion to a Frequency Input Description Benefits The G478 is a DIN rail mount, frequency input signal conditioner with 1800VDC isolation between input, output and power. The field configurable input and output offer flexible, wide ranging
    Original PDF
    ACTIONI/Q® Q510 Multi-Channel RTD Input
    ACTIONI/Q® Q510 Multi-Channel RTD Input Two-WireTransmitter Provides 2 or 4 Current Loop Outputs in Proportion to the PT100Ω RTD Inputs Description Benefits Up to 4 Two-Wire Transmitters in a Single Package High Density DIN Rail Mounting The Q510 is a DIN rail mount, RTD Input, dual or quad channel two-wire transmitter. Each channel
    Original PDF
    ap7380
    ACTION PAK® AP7380 Frequency Input, Field Configurable Signal Conditioner Provides an Isolated DC Output in Proportion to Frequency Input Description Benefits Field Configurable Input Ranges from 2Hz to 10,000Hz The Action Pak Model AP7380 is a frequency input signal conditioner with 1500VDC isolation between
    Original PDF
    g428-0001
    ULTRA SLIMPAK® G428-0001 Thermocouple Input Field Configurable Isolator Provides an Isolated, Linearized DC Output in Proportion to a Thermocouple Input Description Benefits Field Configurable Input Ranges for J, K, T, R, S, E, and B Type Thermocouples Eliminates Ground Loops
    Original PDF
    ap1280
    ACTION PAK® AP1280 & AP1290 Thermocouple Input, Field Configurable Limit Alarms Provides Relay Contact Closures at a Preset Temperature Input Level Description Benefits Field Configurable Input Ranges for E, J, K, R, S and T Type Thermocouples Setpoints Programmable
    Original PDF
    q404-3
    Q404-3 MODEL ActionI/Q® Two-Wire Transmitter Input, Isolator Provides a Fully Isolated DC Output Signal in Proportion to a Two-Wire Transmitter Input Benefits 24VDC Excitation Source for Two-Wire Transmitter Inputs Protects Equipment and Prevents Ground Loops
    Original PDF