| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DCL541A01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable | Datasheet | ||
| DCL541B01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable | Datasheet | ||
| DCM341B01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable / AEC-Q100 | Datasheet | ||
| DCM341A01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable / AEC-Q100 | Datasheet | ||
| TLP385 | Toshiba Electronic Devices & Storage Corporation | Photocoupler (phototransistor output), DC input, 5000 Vrms, 4pin SO6L | Datasheet |
Documents mentioning THERMOCOUPLE INPUTS
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 5b47 | Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates aisolated and protected precision output of 0 to |
Original | ||||
| scc-tc01 | SCC Modules Portable, Modular Signal Conditioning Modules Figure 1. SCC-TC01 and SCC-TC02 Thermocouple Input Modules (thermocouple plug not included) Figure 3. SCC-RTD01 SCC-TC Series Thermocouple Inputs SCC-RTD01 RTD Input Model SCC-TC01 Ch 1 SCC-TC02 1 Description |
Original | ||||
| u280 | Agilent U2802A 31-Channel Thermocouple Input Device Data Sheet Features Overview • Up to 31 thermocouple inputs The Agilent U2802A is a 31-channel thermocouple signal conditioning module with a built-in thermistor for cold junction compensation. The U2802A is |
Original | ||||
| type k thermocouple | Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple Model 8611. This type J thermocouple to frequency converter |
Original | ||||
| fp-tc-120 | FP-TC-120 8-Channel Thermocouple Input Module for FieldPoint FP-TC-120 Available Q1 1998 8 thermocouple or millivolt inputs J, K, T, R, S, and N thermocouple types 16-bit resolution Self-calibrating with stable onboard reference 50/60 Hz noise rejection Isolated input-output |
Original | ||||
| ap4351 | ACTION PAK® AP4351 Thermocouple-Input, Field Configurable Isolator Provides Isolated, Linearized DC Output in Proportion to Thermocouple Input Description Benefits Field Configurable Thermocouple Types Linearized Outputs Wide-Ranging Zero and Span Adjustability (50% |
Original | ||||
| 4718 | USB-4718 8-channel Thermocouple Input USB Module Features NEW Supports USB 2.0 Support voltage, current, and thermocouple inputs No need for the external power 8 thermocouple input channels 2,500 VDC isolation Supports 4~20 mA Wiring terminal on modules |
Original | ||||
| 3b47 | Isolated, Linearized, Thermocouple Input 3B47 FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation. |
Original | ||||
| thermocouple | Sensors - January 2002 - The 1-Wire Thermocouple 1 of 6 wysiwyg://5/http://www.sensorsmag.com/articles/0102/29/main.shtm JANUARY 2002 SENSOR TECHNOLOGY AND DESIGN The 1-Wire Thermocouple A standard thermocouple can be combined with a lithium ion monitor chip |
Original | ||||
| pr-11-2-100-1/4-6-e | 1-4 Channel Flatbed Pen Recorders Accept dc Voltage, Thermocouple and RTD Inputs Model RD3720 1775 $ Basic Unit A Shown with: A) GKMQSS-125G-6 low-noise thermocouple with 30° connector, $27 B) PR-11-2-100-1/4-6-E RTD probe, $66 C) OS36-K-240F infrared thermocouple, $185 |
Original | ||||
| 1746-nt4 | SLC 500t Thermocouple/mV Input Module (Catalog No. 1746-NT4) Product Data The NT4 Thermocouple/mV input module expands the present control capabilities of your SLC 500 fixed or modular system by allowing you to directly interface with any of eight types of thermocouple temperature |
Original | ||||
| 80pk-22 | Temperature Accessories Contact Probes 80PK-22 SureGrip™ Immersion Probe • Type-K thermocouple for use in liquids and gels • Measurement range: -40 to 1090°C DMM Probes 80PK-1 and 80PJ-1 Bead Probe 80AK Thermocouple Adapter • 80PK-1: Type-K thermocouple for |
Original | ||||
| type j thermocouple | Model 8611 Type J and 8612 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency n Cold Junction Compensation n 0 to 500°C or 0 to 1000°C Type J Thermocouple n 0 to 1250°C Type K Thermocouple n Isolated Input to Output |
Original | ||||
| 8511 | Model 8511 Type J and 8512 Type K Thermocouple to Frequency Converters Features Description n Linearized Frequency 10 Hz per degree Centigrade n Cold Junction Compensation n 0 to 500° Type J / K Thermocouple n Isolated Input to Output These thermocouple to frequency converters are designed to |
Original | ||||
|
|
||||||
| visipak | VISIPAKTM V116 & V132 Miniature Temperature/ Process Indicators Provides a 4 Digit Display and Alarm Output from RTD, Thermocouple or DC Inputs Description Benefits Field Configurable Input for Thermocouple, RTD, mV and 4-20mA Signals Three Field Configurable Alarm |
Original | ||||
| ADTECH Analog-Digital Technology, Inc. Isolated | ADTECH Analog-Digital Technology, Inc. Isolated Thermocouple Transmitter Model No. TCT 26 The Adtech Model TCT 26 Isolated Thermocouple Transmitter provides high accuracy conversion of thermocouple signals to a standard process signal such as 4-20 mA DC, 1-5 VDC, or zero-based outputs. It utilizes digital processing with |
Original | ||||
| sloa123 | Application Report SLOA123 – January 2007 Low-Cost, Noise-Immune, Isolated Thermocouple Signal Processor Mike Burns… Signal Chain Applications ABSTRACT This application report describes a low-cost, thermocouple-based, temperature |
Original | ||||
| ACTIONI/Q® Q520 Multi-Channel Thermocouple Input | ACTIONI/Q® Q520 Multi-Channel Thermocouple Input Isolating Two-Wire Transmitter Provides 2 Isolated Current Loops in Proportion to 2 Thermocouple Millivolt Inputs Description Benefits Two 2-Wire Transmitters in a Single Package High Density DIN Rail Mounting |
Original | ||||
| visipak | VISIPAKTM V108 Temperature/Process Indicator Provides a 4 Digit Display and Alarm Output from RTD, Thermocouple or DC Inputs Description Benefits Field Configurable Input for Thermocouple, RTD, mV, and 4-20mA Signals Three Field Configurable Alarm Setpoints with Two |
Original | ||||
| ANALOG DEVICES Monolithic Thermocouple Amplifiers | ANALOG DEVICES Monolithic Thermocouple Amplifiers with ColdJunction Compensation AD594*/AD595* FEATURES Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10mV/°C Built-in Ice Point Compensation |
OCR Scan | ||||
| ad594 | a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation |
Original | ||||
| ad594 | a Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595 FEATURES Pretrimmed for Type J (AD594) or Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/؇C Built-In Ice Point Compensation |
Original | ||||