Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TFS70H Search Results

    TFS70H Datasheets (25)

    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    TFS70H11
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 44.93KB 5
    TFS70H12
    Vectron International Filter Original PDF 26.6KB 4
    TFS70H12A
    Vectron International Filter, Passive, RF & IF Original PDF 25.72KB 4
    TFS70H13
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 126.4KB 5
    TFS70H14
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 43.52KB 5
    TFS70H16
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 54.69KB 5
    TFS70H17
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 45.92KB 5
    TFS70H21
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 60.98KB 6
    TFS70H22
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 50.83KB 5
    TFS70H23
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 125.73KB 5
    TFS70H24
    Vectron International Filter Original PDF 27.33KB 4
    TFS70H25
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 59.44KB 5
    TFS70H25A
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 71.05KB 5
    TFS70H26
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 141.05KB 5
    TFS70H28
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 59.59KB 5
    TFS70H29
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 60.79KB 5
    TFS70H313
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 130.48KB 5
    TFS70H314
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 130.88KB 5
    TFS70H32
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 132.59KB 5
    TFS70H33
    Vectron International Surface Acoustic Wave (SAW) Filter Original PDF 132.57KB 5
    SF Impression Pixel

    TFS70H Price and Stock

    Select Manufacturer

    Microchip Technology Inc TFS70H33

    TFS70H33, Projected EOL: 2050-07-31
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Microchip Technology Inc TFS70H33 8 Weeks
    • 1 $50.00
    • 10 $50.00
    • 100 $50.00
    • 1000 $50.00
    • 10000 $50.00
    Buy Now

    Vectron International (now Microchip) TFS70H25A

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bristol Electronics TFS70H25A 6
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    TFS70H Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    TFS70H29

    Contextual Info: File name : TFS70H29.doc Version 1.1 VI TELEFILTER Filter specification 04.02.2002 TFS 70H29 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc * : 23 °C 0 dBm. for input: Source impedance: Load impedance:


    Original
    TFS70H29 70H29 70H29 PDF

    ae700

    Contextual Info: tfs70H26.doc VI TELEFILTER Filter specification Version 1.1 22.07.2002 TFS 70H26 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 610 Ω  - 8,08 pF. 510 Ω  - 9,54 pF.


    Original
    tfs70H26 70H26 70H26 ae700 PDF

    TFS70H37

    Contextual Info: TFS70H37.doc version 1.0 VI TELEFILTER Filter Specification 16.03.02 TFS 70H37 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedances : for input: for output: 50 Ω | 0 pF 50 Ω | 0 pF Remark: Reference level for the relative attenuation arel of the TFS 70H37 is the insertion loss. The insertion loss ae is defined as the insertion loss at


    Original
    TFS70H37 70H37 70H37 PDF

    Contextual Info: File name : Tfs70H23.doc Version 1.1 VI TELEFILTER Filter specification 26.06.2002 TFS 70H23 1/5 1. Measurement condition : Ambient temperature TA: Input power level: 23 °C 0 dBm. Terminating impedances at fc * : for input: for output: 50 Ω 50 Ω Source impedance:


    Original
    Tfs70H23 70H23 70H23 PDF

    Contextual Info: File name: Tfs70H314.doc Version 1.0 VI TELEFILTER Filter specification 24.05.2002 TFS 70H314 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 258 Ω  -15,6 pF.


    Original
    Tfs70H314 70H314 70H314 PDF

    N-05

    Contextual Info: tfs70H12.doc Version 2.0 VI TELEFILTER Filter Specification 19.02.2001 TFS 70H12 - 1/4 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C. dBm. for input: for output: 50 Ω  0 pF. 50 Ω  0 pF.


    Original
    tfs70H12 70H12 N-05 PDF

    70H25A

    Abstract: TFS70H25A
    Contextual Info: TFS70H25A.doc version 1.2 VI TELEFILTER 19.07.01 Filter Specification TFS 70H25A 1/5 Measurement condition Ambient temperature: 25 °C Input power level: 10 dBm Terminating impedances at fc* : for input: for output: 350 Ω ⎟⎢ -13,7 pF 450 Ω ⎟⎢ -12,1 pF


    Original
    TFS70H25A 70H25A PDF

    TFS70H28

    Contextual Info: File name : TFS70H28.doc Version 1.1 VI TELEFILTER Filter specification 04.02.2002 TFS 70H28 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc * : 23 °C 0 dBm. for input: Source impedance: Load impedance:


    Original
    TFS70H28 70H28 70H28 PDF

    TFS70H16

    Contextual Info: File name: Tfs70H16.doc Version 1.0 VI TELEFILTER Filter specification 22.08.2002 TFS 70H16 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C. dBm. for input: for output: 50 Ω ⎟⎢ 0 pF. 50 Ω ⎟⎢ 0 pF.


    Original
    Tfs70H16 70H16 70H16 PDF

    70H44

    Abstract: DB3176
    Contextual Info: File name: Tfs70H44.doc version 1.2 VI TELEFILTER Filter Specification 30.07.2002 TFS 70H44 1/5 Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 23 °C dBm for input: for output: 486 Ω  - 10,2 pF


    Original
    Tfs70H44 70H44 70H44 DB3176 PDF

    507l1

    Abstract: 70H313
    Contextual Info: File name: Tfs70H313.doc Version 1.1 VI TELEFILTER Filter specification 15.04.2002 TFS 70H313 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 400 Ω  -12,3 pF.


    Original
    Tfs70H313 70H313 70H313 507l1 PDF

    TFS70H21

    Abstract: TFS70H22 TFS70H23 TFS70H24 TFS70H25 TFS70H26 TFS70H28 TFS70H29 tfs70h33 TFS70H16
    Contextual Info: Product Data Sheet TFS70H Standard 70 MHz SAW Filter Features Industry Standard 14 pin & 18 pin DIP and SMD packages 6 pin versions 40 different codes available Bandwidths ranging from 0.25 to 40MHz Compatible with existing industry standard specifications


    Original
    TFS70H 40MHz TFS70H 70MHz TFS70H21 TFS70H22 TFS70H23 TFS70H24 TFS70H25 TFS70H26 TFS70H28 TFS70H29 tfs70h33 TFS70H16 PDF

    100 n37

    Abstract: n37 transistor TFS70H38
    Contextual Info: TFS70H38.doc version 1.1 VI TELEFILTER Filter Specification 11.09.01 TFS 70H38 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 10 dBm Terminating impedances : for input: for output: 50 Ω | 0 pF 50 Ω | 0 pF Remark: Reference level for the relative attenuation arel of the TFS 70H38 is the insertion loss. The insertion loss ae is defined as the insertion loss at


    Original
    TFS70H38 70H38 70H38 100 n37 n37 transistor PDF

    70H25

    Abstract: TFS70H25 IEC 60 603 13
    Contextual Info: TFS70H25.doc version 1.3 VI TELEFILTER Filter Specification 03.01.02 TFS 70H25 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances *: for input: for output: 25 °C 10 dBm 385 Ω 524 Ω // -13,4 pF // -11,6 pF Remark:


    Original
    TFS70H25 70H25 70H25 IEC 60 603 13 PDF

    TFS70H24

    Contextual Info: File name : TFS70H24.doc Version 1.0 VI TELEFILTER Filter Specification 25.01.2001 TFS 70H24 - 1/4 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm. for input: Q-value of matching elements: Source impedance:


    Original
    TFS70H24 70H24 PDF

    Contextual Info: File name: Tfs70H32.doc Version 1.0 VI TELEFILTER Filter specification 11.04.2002 TFS 70H32 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 134 Ω  - 22,1 pF.


    Original
    Tfs70H32 70H32 70H32 PDF

    L12149

    Contextual Info: File name: Tfs70H35.doc Version 1.0 VI TELEFILTER Filter specification 23.07.2002 TFS 70H35 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 23 °C. dBm. for input: for output: 450 Ω  - 26,3 pF


    Original
    Tfs70H35 70H35 70H35 L12149 PDF

    Contextual Info: tfs70H11.doc Version 1.2 VI TELEFILTER Filter Specification 19.11.2002 TFS 70H11 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C. dBm. for input: for output: 50 Ω ⎟⎢ 0 pF. 50 Ω ⎟⎢ 0 pF.


    Original
    tfs70H11 70H11 70H11 PDF

    Contextual Info: tfs70H14.doc Version 1.1 VI TELEFILTER Filter specification 16.04.2002 TFS 70H14 1/5 Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C dBm for input: for output: 50 Ω // 0 pF 50 Ω // 0 pF Characteristics :


    Original
    tfs70H14 70H14 70H14 referenc14 PDF

    Contextual Info: File name: Tfs70H17.doc Version 1.0 VI TELEFILTER Filter specification 20.02.2002 TFS 70H17 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C. dBm. for input: for output: 50 Ω ⎟⎢ 0 pF. 50 Ω ⎟⎢ 0 pF.


    Original
    Tfs70H17 70H17 70H17 PDF

    Contextual Info: File name: Tfs70H43.doc Version 1.0 VI TELEFILTER Filter specification 18.07.2002 TFS 70H43 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 23 °C. dBm. for input: for output: 454 Ω  - 9,26 pF


    Original
    Tfs70H43 70H43 70H43 PDF

    datecode DIN IEC 62

    Contextual Info: tfs70H13.doc Version 1.1 VI TELEFILTER Filter specification 24.06.2002 TFS 70H13 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C. dBm. for input: for output: 50 Ω  0 pF. 50 Ω  0 pF.


    Original
    tfs70H13 70H13 70H13 datecode DIN IEC 62 PDF

    70h33

    Abstract: tfs70h33
    Contextual Info: File name: Tfs70H33.doc Version 1.0 VI TELEFILTER Filter specification 26.04.2002 TFS 70H33 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 151 Ω  - 21,3 pF.


    Original
    Tfs70H33 70H33 70H33 PDF

    Contextual Info: tfs70H22.doc VI TELEFILTER Filter specification Version 1.1 04.03.2002 TFS 70H22 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc * : 25 °C. dBm. for input: for output: 180 Ω ⎟⎢ - 17,6 pF. 240 Ω ⎟⎢ - 13,7 pF.


    Original
    tfs70H22 70H22 70H22 PDF