Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SWITCHING SPARK GAP Search Results

    SWITCHING SPARK GAP Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ICL7662MTV/B
    Rochester Electronics LLC ICL7662 - Switched Capacitor Converter, 10kHz Switching Freq-Max, CMOS PDF Buy
    ICL7660SMTV
    Rochester Electronics LLC ICL7660 - Switched Capacitor Converter, 0.02A, 17.5kHz Switching Freq-Max, CMOS, MBCY8 PDF Buy
    LM1578AH/883
    Rochester Electronics LLC LM1578 - Switching Regulator, Current-mode, 0.75A, 100kHz Switching Freq-Max, MBCY8 - Dual marked (5962-8958602GA) PDF Buy
    DG201AK/B
    Rochester Electronics LLC DG201A - 15.0V SPST CMOS Switch PDF Buy
    IH5012CDE
    Rochester Electronics LLC IH5012 - SPST, 4 Func, 1 Channel, CDIP16 PDF Buy

    SWITCHING SPARK GAP Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    B88069X

    Abstract: SURGE ARRESTER EPCOS 230 07 0 SURGE ARRESTER EPCOS 350 07 0 E163070 diode T87A B88069X FREE SHIPPING On May-14-13 at 01:17:47 PDT, seller added the following information: F health data sheet egypt
    Contextual Info: EPCOS Product Profile 2015 Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken www.epcos.com Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken Contents Inhalt Important notes Wichtige Hinweise


    Original
    b88069xsurge arrester epcos 230 07 0surge arrester epcos 350 07 0e163070+3diode t87ab88069x free shipping on may-14-13 at 01:17:47 pdt, seller added the following information: fhealth data sheet egypt PDF

    SPARK GAP

    Abstract: CAS06XG spark gap 100 kv
    Contextual Info: Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data DC spark-over voltage 1 2) 350 . 900 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1100 < 1000 V V < 1400 < 1300 V V


    Original
    cas06xgb88069x1210t50257845/vde0845spark gap+1spark gap 100 kv PDF

    spark gap

    Abstract: 100 kv spark gap spark switching spark gap CAS06XG
    Contextual Info: Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data DC spark-over voltage 1 2) 350 . 900 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1100 < 1000 V V < 1400 < 1300 V V


    Original
    cas06xgb88069x1210t50257845/vde0845spark gap+3100 kv spark gapsparkswitching spark gap PDF

    igniter transformer

    Abstract: xenon hid ballast xenon lamp igniter gas cooker circuit ignitor Ignition Transformer xenon igniter xenon ballast pulse IGNITION Epcos spark gap spark gap ignitor
    Contextual Info: Switching Spark Gaps Schaltfunkenstrecken Basic circuit pulse igniter Prinzipschaltkreis Impulszündgerät R C General Switching spark gap Schaltfunkenstrecke Load Last RAB0223-W Fig. / Bild 1 General technical information It is increasingly common practice to


    Original
    rab0223-wigniter transformerxenon hid ballastxenon lamp igniter+7gas cooker circuit ignitorignition transformerxenon igniterxenon ballastpulse ignitionepcos spark gapspark gap ignitor PDF

    EPCOS CS 230

    Abstract: spark gap CAS02X-067
    Contextual Info: Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1 2) 200 . 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-067b88069x0670t502epcos cs 230spark gap PDF

    spark gap

    Abstract: EPCOS CS 230 Spark CAS02X-091
    Contextual Info: Switching Spark Gap CAS02X-091 Ordering code: B88069X0910T502 DC spark-over voltage 1 2) 190 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-091b88069x0910t502spark gapepcos cs 230+1spark PDF

    spark gap

    Abstract: CAS02X-047
    Contextual Info: Switching Spark Gap CAS02X-047 Ordering code: B88069X0470T502 DC spark-over voltage 1 2) 215 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-047b88069x0470t502spark gap PDF

    spark gap

    Abstract: B88069X0680 CAS02X-068 EPCOS CS 230 B88069X0680T502
    Contextual Info: Switching Spark Gap CAS02X-068 Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-068b88069x0680t502spark gapb88069x0680+1epcos cs 230 PDF

    EPCOS 230 06 O

    Abstract: spark gap CAS02X-069 EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02X-069 Ordering code: B88069X0690T502 DC spark-over voltage 1 2) 205 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-069b88069x0690t502epcos 230 06 ospark gap+1epcos cs 230 PDF

    EPCOS CS 230

    Abstract: spark gap CAS02X-087
    Contextual Info: Switching Spark Gap CAS02X-087 Ordering code: B88069X0870T502 DC spark-over voltage 1 2) 180 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-087b88069x0870t502epcos cs 230spark gap PDF

    ignition spark

    Abstract: spark gap cas02xg Spark EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02XG Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02xgb88069x0680t502ignition sparkspark gap+2sparkepcos cs 230 PDF

    spark gap

    Abstract: CAS02X-093 EPCOS CS 230
    Contextual Info: Switching Spark Gap CAS02X-093 Ordering code: B88069X0930T502 DC spark-over voltage 1 2) 180 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage


    Original
    cas02x-093b88069x0930t502spark gapepcos cs 230 PDF

    EPCOS 230 03 O

    Abstract: spark gap EPCOS CS 230 B88069X4290T502 CAS02X-429
    Contextual Info: Switching Spark Gap CAS02X-429 Ordering code: B88069X4290T502 DC spark-over voltage 1 2) 235 . 260 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage


    Original
    cas02x-429b88069x4290t502epcos 230 03 ospark gap+1epcos cs 230 PDF

    B88069X1200T502

    Abstract: CAS04XG
    Contextual Info: Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data DC spark-over voltage 1 2) 350 . 550 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 900 < 800 V V < 1200 < 1100 V V Insulation resistance at 300 Vdc


    Original
    cas04xgb88069x1200t50257845/vde0845 PDF

    EPCOS 230 09 O

    Abstract: capacitor discharge ignition B88069X0710 EPCOS CS 230 spark gap CAS02X-071 B88069X0710T502
    Contextual Info: Switching Spark Gap CAS02X-071 Ordering code: B88069X0710T502 DC spark-over voltage 1 2) 215 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage


    Original
    cas02x-071b88069x0710t502epcos 230 09 ocapacitor discharge ignition+3b88069x0710epcos cs 230spark gap PDF

    EPCOS CS 230

    Abstract: EPCOS 230 01 O spark gap CAS02X-4731 EPCOS 230 01 capacitor 0.1 uF 25 v
    Contextual Info: Switching Spark Gap CAS02X-4731 Ordering code: B88069X4731T502 DC spark-over voltage 1 2) 190 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage


    Original
    cas02x-4731b88069x4731t502epcos cs 230epcos 230 01 o+3spark gapepcos 230 01capacitor 0.1 uf 25 v PDF

    EPCOS 230

    Abstract: cm 230 spark gap CAM02X Epcos spark gap EPCOS 230 03 O
    Contextual Info: Switching Spark Gap CAM02X Ordering code: B88069X5410T502 DC spark-over voltage 1 2) 230 ± 15 V % Initial values Ignition time tI after 24 hours in darkness 3) 95 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time Switching operations at +25; 125 °C


    Original
    cam02xb88069x5410t502epcos 230cm 230+3spark gapepcos spark gapepcos 230 03 o PDF

    epcos EC 90 11 O

    Abstract: EPCOS 470 11 O em epcos 3000 Epcos 5000 11 O epcos EC 90 14 O EPCOS 1400 14 O epcos SURGE ARRESTERS gas discharge epcos 260 11 EPCOS ec 600 10 O EPCOS 350 10 O
    Contextual Info: Arresters Surge Arresters Switching Spark Gaps Überspannungsableiter Surge Arresters 2-Elektroden-Ableiter 2-electrode surge arresters Nennansprechgleichspannung DC spark-over voltage V Light duty EM M5 EC Medium duty N8 A7 L7 4500 Heavy duty A8 A83 2,5/2,5


    Original
    epcos ec 90 11 oepcos 470 11 oem epcos 3000epcos 5000 11 o+6epcos ec 90 14 oepcos 1400 14 oepcos surge arrestersgas discharge epcos 260 11epcos ec 600 10 oepcos 350 10 o PDF

    Contextual Info: TX Series Triggered Spark Gaps Features • Rugged ceramic-metal construction • Short delay times • Miniature size • High reliability Description The TX is a series of miniature triggered spark gaps designed for high reliability switching with Main Static


    Original
    PDF

    spark gap switch

    Abstract: Triggered spark gap
    Contextual Info: Mini-Triggered Spark Gaps & Transformers Key Features • • • • • High reliability Extremely low jitter Environmentally durable Small size Matching trigger transformers Applications • • • • Excelitas’ Mini-Triggered Spark Gaps are designed for high reliabilty switching up to 4 kV


    Original
    spark gap switchtriggered spark gap PDF

    flashtube

    Abstract: Triggered spark gap CP CLARE spark gap switch cpclare spark gap Triggered spark gap 7.5 kv TA-10 TG-221 TG-222
    Contextual Info: HIGH-ENERGY TRIGGERED SPARK GAPS Triggergaps DESCRIPTION CP Clare's Triggergaps are high-energy spark gaps that are capable of switching stored energy in a fraction of a microsecond. Triggergaps require no standby power, are extremely rugged, and require only a low-energy, highvoltage triggering pulse. The miniature TA series 1-15kV provides switching capability for pulses with energy


    Original
    1-15kvtg-221tb-251-800-cpclare+9flashtubetriggered spark gapcp clarespark gap switchcpclarespark gaptriggered spark gap 7.5 kvta-10tg-222 PDF

    Triggered spark gap

    Abstract: Triggered spark gap 7.5 kv detonator clare spark gap MIL-STD-202D method 107 MIL-STD-202D 2N6798 EBW circuit HIGH ENERGY IGNITION CIRCUIT MIL-STD-202D 107
    Contextual Info: HIGH-ENERGY TRIGGERED SPARK GAPS TX4.5 DESCRIPTION CP Clare’s Triggergaps are high-energy spark gaps that are capable of switching stored energy in a fraction of a microsecond. Triggergaps use no standby power, are extremely rugged and require only a low energy high voltage triggering pulse.


    Original
    1-800-cpclare50kohms2n6798triggered spark gap+8triggered spark gap 7.5 kvdetonatorclare spark gapmil-std-202d method 107mil-std-202debw circuithigh energy ignition circuitmil-std-202d 107 PDF

    Triggered spark gap

    Abstract: PerkinElmer spark gap spark gap trigger transformer TR-2206 TR-2207 PerkinElmer spark gaps PerkinElmer trigger mode EG*G Optoelectronics Triggered spark gap pulse width 100 kv spark gap
    Contextual Info: P erkinElmer’s Mini-Triggered Mini-Triggered Spark Gaps and Transformers EVERYTHING IN A Spark Gaps are designed for high relia- NEW bility switching up to 4 kV and 10 kA. LIGHT. Constructed of hermetically sealed ceramic-metal, filled with pressurized gas, they are typically used for activating


    Original
    triggered spark gapperkinelmer spark gapspark gap trigger transformertr-2206+6tr-2207perkinelmer spark gapsperkinelmer trigger modeeg*g optoelectronicstriggered spark gap pulse width100 kv spark gap PDF

    EPCOS 230 03 O

    Abstract: EPCOS CS 230 EPCOS 230 03 spark gap epcos cs marking green IEC 60068-1 CAS02XC
    Contextual Info: Switching Spark Gap CAS02XC Ordering code: B88069X4040B502 DC spark-over voltage 1 2) 190 . 255 V 9 000 000 Ignitions 230 1 1 40 ~ 150 Vac kΩ µF µH A Insulation resistance at 100 Vdc > 0.1 GΩ Capacitance at 1 MHz <2 pF Weight ~ 1.5 g Operation and storage temperature


    Original
    cas02xcb88069x4040b502epcos 230 03 oepcos cs 230+4epcos 230 03spark gapepcos cs marking greeniec 60068-1 PDF