SW961230 Search Results
SW961230 Datasheets (2)
Celduc Relais
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| SW961230 | Celduc Relais | MOTOR REVERSER (Ready to Use) | Original | 263.17KB | 5 | ||
| SW961230 | Celduc Relais | MOTOR REVERSER | Original | 192.03KB | 5 |
SW961230 Price and Stock
celduc relais
celduc relais SW961230Relay: solid state; 4.5A; Uswitch: 24÷500VAC; 3-phase,reversing |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
SW961230 | 1 |
|
Get Quote | |||||||
|
SW961230 | 1 | 1 |
|
Buy Now | ||||||
|
SW961230 | Box | 1 |
|
Buy Now | ||||||
|
SW961230 | 2 |
|
Buy Now | |||||||
|
SW961230 | 2 |
|
Buy Now | |||||||
Documents mentioning SW961230
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| motor reverser | INVERSEURS DE SENS DE ROTATION MOTOR REVERSER ( Ready to use) page 1 /5 F/GB SW961230 Le relais SW961230 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le produit avec dissipateur intégré , directement montable sur |
Original | ||||
| sw961230 | S/MOT/SW961230/A/16/03/2000 page 1 /5 F/GB MOTOR REVERSER ( Ready to use) SW961230 Farnell order 3x400VAC 4KW celduc® relais code SG961230 code 399-6372 Boitier IP20 IP20 housing 155 90 100 The relay SW961230 is designed for controlling and inverting the direction of a |
Original | ||||
| sw961230 | S/MOT/SW961230/A/16/03/2000 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER ( Ready to use) page 1 /5 F/GB SW961230 Le relais SW961230 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le produit avec dissipateur intégré , directement montable sur |
Original | ||||
| sv969300 | S/MOT/SV969300/A/16/03/2000 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER page 1 /5GB SV969300 3x400VAC 4KW two legs model Le relais SV969300 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le calibre des thyristors est de 50AR MS (75A sur demande) , |
Original | ||||
| Pro d i u e G t c u d www.celduc-relais.com | Pro d i u e G t c u d www.celduc-relais.com celduc MADE IN FRANCE ® relais 1964-2014 YEARS REED RELAYS AND SWITCHES SOLID STATE RELAYS MAGNETIC SENSORS Dear customers, dear readers, At celduc® we are very proud to be celebrating our 50th anniversary in 2014! |
Original | ||||
| Solid state relays celdu ¤ cr elais Scope Heating | Solid state relays celdu ¤ cr elais Scope Heating Plasturgy Furnaces Power supply distribution systems Air conditioning Textile Home heating Infrared heating Drying Thermoforming Etc… Motor starting Pumps Compressors Plasturgy (see above) Conveyors Fans |
Original | ||||
| celduc | www.celduc.com Selection Guide ED G E T H AT CO M P E TIVE TI PRO SOLID STATE RELAYS OU U D TO S E RV E Y MAGNETIC SENSORS . REED RELAYS AND SWITCHES elais Word of Introduction Dear Customers, dear Readers, T IV E ED Keep our customers satisfied !! This “selection guide” catalogue is a picture of the products that are available |
Original | ||||
| sv969500 | S/MOT/SV969500/11/12/2001 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER page 1 /5GB SV969500 Le relais SV969500 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le calibre des thyristors est de 75ARMS , ce qui permet de |
Original | ||||
| sg969300 | S/MOT/SG969300/A/16/03/2000 page 1 /4GB INVERSEURS DE SENS DE ROTATION MOTOR REVERSER SG969300 Le relais SG969300 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs |
Original | ||||
| Selection Guide REED RELAYS AND SWITCHES MAGNETIC | Selection Guide REED RELAYS AND SWITCHES MAGNETIC SENSORS SOLID STATE RELAYS IV E ED We are pleased to present the third version of our short form catalogue. The last 3 years have seen a dramatic growth in customers in a diverse range of industries, allowing us to demonstrate high quality, innovative design techniques incorporated in many of the new products shown in this catalogue. |
Original | ||||
| Pro d i u e G t c u d www.celduc-relais.com | Pro d i u e G t c u d www.celduc-relais.com celduc MADE IN FRANCE ® relais 1964-2014 YEARS REED RELAYS AND SWITCHES SOLID STATE RELAYS MAGNETIC SENSORS Dear customers, dear readers, At celduc® we are very proud to be celebrating our 50th anniversary in 2014! |
Original | ||||
| sw960330 | S/MOT/SW960330/A/16/03/2000 page 1 /5 F/GB MOTOR REVERSER ( Ready to use) SW960330 Farnell order 3x400VAC 1,5KW celduc® relais code SG960330 code 399-6360 Boitier IP20 IP20 housing 72 100 The relay SW960330 is designed for controlling and inverting the direction of a |
Original | ||||
| sw960330 | S/MOT/SW960330/A/16/03/2000 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER ( Ready to use) page 1 /5 F/GB SW960330 Le relais SW960330 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le produit directement montable sur rail DIN avec un calibre |
Original | ||||
| sv969300 | S/MOT/SV969300E/A/01/10/2003 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER Entraxe 47,5mm /4,7,5mm mounting page 1 /5GB SV969300E 3x400VAC 4KW two legs model Le relais SV969300 est étudié pour démarrer et inverser le sens de rotation de moteurs triphasés asynchrones , avec la commutation de 2 phases uniquement ( 4 commutateurs : 2 legs) . Le calibre des thyristors est de 50AR MS (75A sur demande) , |
Original |