| zd-51001-bms | BMS INTERFACE Datasheet ZD-51001-BMS Issue a : 17/5/96 Staefa Interface Unit Andover Interface Unit Elm BMS Interface Supervisor BMS System Description: The Building Management System (BMS) Interface communicates with Staefa, Andover or Utah HVAC systems. Their use enables HVAC to be reported via the |
Original | ||||
| fs-t1l2 | 1 837 FS-T1L2, FS-T1L5 Probe sensor • T1 sensor element • Universally applicable as immersion, strap-on, wall surface or air temperature sensor • Suitable for retrofit and expansion of existing systems • An advanced forming process is used in the manufacture of the |
Original | ||||
| qbe620-p | 1 904 Pressure sensor for liquid and gaseous media QBE620-P… Pressure sensor for the measurement of positive pressure in HVAC applications. • Piezo-resistive system of measurement • DC 0…10 V output signal • Complete sensor cast in synthetic resin |
Original | ||||
| pressure sensor | 1 920 Differential pressure sensor QBE63-DP… for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems. |
Original | ||||
| qfa81 | 1 Room Hygrostats 513 QFA81… for relative humidity QFA81.1 QFA81 On / off hygrostat with microswitch, with humidity sensor, with plastic texture sensing strip (good linearity, wide measuring range), for the control of humidification equipment, for the control of dehumidification equipment, |
Original | ||||
| qaa64 | 1 Room Temperature Sensor 722 QAA64 vandalproof though concealed mounting Use Acquisition of room temperature in spaces where the detector needs to be protected against damage or destruction by people. Such spaces are public buildings like schools, administrative buildings, multipurpose halls, etc. |
Original | ||||
| qbe61 | 1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0…10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants. |
Original | ||||
| qbe61 | 1 Pressure Detectors 901 QBE61.1… Active pressure detector delivering a DC 0…10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning |
Original | ||||
| qbe61 | 1 1923P01 923 Differential pressure sensors QBE61.3-DP… for neutral or slightly aggressive gases and liquids • Operating voltage AC 24 V or DC 18…33 V Output signal DC 0…10 V Connecting male thread G ½" 3 versions covering a total differential pressure range of 0 … 10 bar |
Original | ||||
| air velocity sensor | 1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations (supply or extract air control), or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume |
Original | ||||
| hygro | 1 Duct Hygrostats 514 QFM81… for relative humidity QFM81.21 QFM81.2 On / off hygrostat with microswitch, with temperature-compensated humidity sensor for temperature-independent humidity measurements, with stabilized sensing strip (good linearity, very stable even at high humidity, |
Original | ||||
| qpa84 | 1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1) ) sensor, operating voltage AC 230 V, two-position output (non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by |
Original | ||||
| 1860p01 | 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0…10 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement accuracy ± 3 % r. h. within the comfort range |
Original | ||||
| fr-t1k | 1 735 FR-T1K Room temperature sensor Compact room sensor for measurement of the air temperature in conjunction with HVAC systems • T1 measuring element Suitable for wall-mounting Ideal where space is limited Discreet appearance FR-T1K Technical data |
Original | ||||
|
|
||||||
| 1 656 PB-T1 Room temperature sensor Room sensor | 1 656 PB-T1 Room temperature sensor Room sensor for HVAC systems, for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes • Socket for the PRONTO IRC ZS1 service terminal • Trimming potentiometer for |
Original | ||||
| fk-t1k | 1 775 FK-T1K.. Duct temperature sensor Sensor for measurement of duct air temperature in HVAC systems • T1 measuring element • Sensor probe easy to remove without dismantling sensor housing or disconnecting wiring • Fast response time • Plastic pipe between housing and |
Original | ||||
| Sample Code I2C For communication with the SHT3x | Sample Code I2C For communication with the SHT3x Humidity and Temperature Sensor through the I2C Interface Introduction This document contains sample code in C for communication with the SHT3x humidity and temperature sensor through the I2C Interface. The purpose of the code is to ease the user’s software programming when implementing SHT3x sensors. Besides |
Original | ||||
| clamp-on | 1 804 Clamp-on temperature sensor QAD100.1 Use The sensor is used for acquiring the medium temperature on the surface of pipes (e.g. the heating water in heating, ventilation or air conditioning plants). It is designed for use in connection with automation equipment, display and logging |
Original | ||||
| fr-t1 | 1 736 FR-T1/A Room temperature sensor Room sensor for HVAC systems for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes FR-T1/A Technical data Application range 0… 50 °C Measuring element |
Original | ||||
| solar sensor | 942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to |
Original | ||||
| RS 824-705 BELIMO NM 24-SR damper motor 8 Nm | RS 824-705 BELIMO NM 24-SR damper motor 8 Nm Dampers up to approx. 1.5 m2 Modulating damper motor (24 VAC) Control 0…10 VDC and position feedback 2…10V D C Self-adapting, automatic angleof-rotation and running-time adjustment Improved functional safety |
OCR Scan | ||||
| Model 481 Miniature Single Element Pyroelectric | Model 481 Miniature Single Element Pyroelectric IR Detector With Source Follower Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 481 contains a single lithium |
Original | ||||
| Model 459 Twin Channel Optically Isolated | Model 459 Twin Channel Optically Isolated Pyroelectric IR Detector with Source Follower Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 -4,437,003 - 4,441,023 - 4,523,095 Model 459 contains two lithium tantalate sensing elements and two JFET |
Original | ||||
| Model 482 High Gain Thermally Compensated | Model 482 High Gain Thermally Compensated Pyroelectric IR Detector Manufactured under one or more of the following U.S. patents: 3,839,640 - 4,218,620 - 4,326,663 - 4,384,207 - 4,437,003 - 4,441,023 - 4,523,095 Model 482 consists of two lithium tantalate sensing elements, a load |
Original | ||||