SN35HH Search Results
SN35HH Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: FLT011X Issue 7 9th December 2011 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only FlexLiteTM HIGH PERFORMANCE EQUIPMENT WIRE 600V/150°C The complete requirements for procuring the wire described herein shall consist of this document. |
Original |
flt011x00v/150flt011x-0flt011x-1+2 | |
UL STYLE 3557
Abstract: E38136
|
Original |
wcd3106e38136flhtc0311number550926+2 | |
|
Contextual Info: 99M0111 Issue 8 18th August 2011 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only WIRE, MODIFIED POLYESTER INSULATED, 600 VOLT, 120°C, LIGHTWEIGHT The complete requirements for procuring the wire described herein shall consist of this document |
Original |
99m011199m0111-28-99m0111-26-99m0111-24-+6 | |
|
Contextual Info: FLDWC0311 Issue 5 8th February 2012 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only FlexLite DUAL WALL HOOKUP WIRE, TIN PLATED COPPER, RADIATION-CROSSLINKED, MODIFIED POLYALKENE/PVDF INSULATED, 125°C, 600 VOLT The complete requirements for procuring the wire described herein shall consist of this document, Test Regime WSD3106 UK |
Original |
fldwc0311wsd3106wcd3106127mm+2 | |
ray-101
Abstract: RAY-101-7 Tyco Electronics
|
Original |
ray-10xissue11ray-10x-3ray-10x-4+9 | |
|
Contextual Info: TR16 Issue 7 10th August 2011 Specification Control Drawing Page 1 of 2 Page 2 is for internal use only WIRE, ELECTRIC, RADIATION CROSSLINKED POLYOLEFIN INSULATED,TIN COATED COPPER, 600/1000 VOLT , 125°C Flexible Tin Plated Copper Conductor to IEC 60228 Class 6 |
Original |
sn35hh | |
|
Contextual Info: 100G0111 Issue 9 14th November 2012 Customer Drawing Page 1 of 2 Page 2 is for internal use only WIRE, HALOGEN FREE, THIN WALL, 750/1300 VOLT AC, 125°C The complete requirements for procuring the wire described herein shall consist of this document. Conductor Tin Plated Copper |
Original |
100g0111sn35hh | |
|
Contextual Info: 44A0111-28, 30 Issue 8 7th August 2012 Specification Control Drawing Page 1 of 2 Page 2 for internal use only WIRE, ELECTRICAL, RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER INSULATED, TIN COPPER CONDUCTOR, 150°C, 600 VOLT, LIGHTWEIGHT. The complete requirements for procuring the wire described herein shall consist of this document. |
Original |
44a0111-2844a0111-30-44a0111-28-sn35hh | |
Tyco Electronics
Abstract: RAY101 ray-101
|
Original |
ray-10xissue12ray-10x-3ray-10x-4+9 |