S8980 Search Results
S8980 Datasheets (1)
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| S8980 | Hamamatsu | IC IMAGE SENSOR B/W CCD 1500X1000 | Original | 161.62KB | 7 |
S8980 Price and Stock
Vishay Intertechnologies RWR81S8980BSBSL- Bulk (Alt: RWR81S8980BSBSL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RWR81S8980BSBSL | Bulk | 18 Weeks | 100 |
|
Buy Now | |||||
Vishay Intertechnologies RWR80S8980BSRSL- Custom Tape W/Leader (Alt: RWR80S8980BSRSL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RWR80S8980BSRSL | Tape w/Leader | 18 Weeks | 100 |
|
Buy Now | |||||
Vishay Intertechnologies RWR80S8980FSRSL- Custom Tape W/Leader (Alt: RWR80S8980FSRSL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RWR80S8980FSRSL | Tape w/Leader | 18 Weeks | 100 |
|
Buy Now | |||||
Vishay Intertechnologies RWR89S8980BSB12- Bulk (Alt: RWR89S8980BSB12) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RWR89S8980BSB12 | Bulk | 12 Weeks | 100 |
|
Buy Now | |||||
Vishay Intertechnologies RWR80S8980FSBSL- Bulk (Alt: RWR80S8980FSBSL) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RWR80S8980FSBSL | Bulk | 18 Weeks | 100 |
|
Buy Now | |||||
S8980 Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
fw300Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making |
Original |
s8980s8981-02s898102s8981+2 | |
S1503
Abstract: 5343
|
Original |
s8980s10810-11kmpd1123e04s1503+1 | |
dental sensor
Abstract: S1500 S1502 S8980 S8981-02 CCD 22 pin fax
|
Original |
s8980s8981-02cse-171kmpd1084e03+5 | |
|
Contextual Info: S8980P Linear ICs Crosspoint Switch Circuit status Military/High-RelN Nom. Supp V 5.0 Minimum Operating Temp (øC)-55 Maximum Operating Temp (øC)125 Package StyleDIP Mounting StyleT Pinout Equivalence Code40-22 # Pins40 Ckt. (Pinout) NumberLN04000022 DescriptionDigital Time/Space Switch for Voice/Data |
Original |
s8980pcode40-22pins40numberln04000022 | |
DS8980J
Abstract: DS8980N DS8981J DS8981N J18A N18A DS8981 DS8980
|
OCR Scan |
ds898qds8981ds8980ds8980j+5 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980 |
Original |
s8980s8981s7362-01se-171 | |
ST14 codec chip
Abstract: s6802 6802 micro pro 6802 processor S69B
|
OCR Scan |
s898032-channelst14 codec chips6802+3 | |
|
Contextual Info: , •> Go u l d Digital Time/Space Crosspoint Switch AMI Advanced Product Description * Semiconductors S8980 Features General Description □ ST-BUS Serial Telecom Bus Compatible □ 8-Line x 32-Channel Inputs □ 8-Line x 32-Channel Outputs □ 256 Ports Non-Blocking Switch |
OCR Scan |
s898032-channel | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980 |
Original |
s8980s8981s7362-01se-171 | |
6802 processor
Abstract: stm cl-130 S6802 CL-130 STM
|
OCR Scan |
s898032-channel6802 processorstm cl-130+2 | |
S8981Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, |
Original |
s8980s8981-02cs898honese-171+1 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980 |
Original |
s8980s8981s7362-01se-171 | |
|
Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 |
Original |
s8980s10810-11se-171kmpd1123e03 | |
dental sensor
Abstract: S1500 S1502 S7362-01 S8980 S8981 image sensor x-ray dental x-ray sensor
|
Original |
s8980s8981s7362-01se-171+5 | |
|
|
|||
pin out mdr 50 pin CONNECTORContextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 |
Original |
s8980s10810-11kmpd1123e05pin out mdr 50 pin connector | |
|
Contextual Info: CCD area image sensors S8980 S10810 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 mm, |
Original |
s8980s1081012telephonese-171+1 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making |
Original |
s8980s8981-02s898102s8981+1 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making |
Original |
s8980s8981-02s898102s8981+1 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980 |
Original |
s8980s8981s7362-01se-171 | |
S8980
Abstract: "Image Sensors" dental sensor S1500 S1502 dental x-ray sensor image sensor x-ray
|
Original |
s8980s10810se-171kmpd1123e02+6 | |
dental x-ray sensor
Abstract: S8981-02 S1500 S1502 S8980 S8981 S1503
|
Original |
s8980s8981-02s898102s8981+5 | |
icdg
Abstract: S8980
|
OCR Scan |
s8980icdg | |
|
Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 |
Original |
s8980s10810-11incorporate53b1201+1 | |
|
Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, |
Original |
s8980s8981-02cs898honese-171 | |