Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    S8980 Search Results

    S8980 Datasheets (1)

    Hamamatsu
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    S8980
    Hamamatsu IC IMAGE SENSOR B/W CCD 1500X1000 Original PDF 161.62KB 7
    SF Impression Pixel

    S8980 Price and Stock

    Vishay Intertechnologies

    Vishay Intertechnologies RWR81S8980BSBSL

    - Bulk (Alt: RWR81S8980BSBSL)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas RWR81S8980BSBSL Bulk 18 Weeks 100
    • 1 -
    • 10 -
    • 100 $74.94
    • 1000 $73.81
    • 10000 $73.06
    Buy Now

    Vishay Intertechnologies RWR80S8980BSRSL

    - Custom Tape W/Leader (Alt: RWR80S8980BSRSL)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas RWR80S8980BSRSL Tape w/Leader 18 Weeks 100
    • 1 -
    • 10 -
    • 100 $83.24
    • 1000 $81.99
    • 10000 $81.16
    Buy Now

    Vishay Intertechnologies RWR80S8980FSRSL

    - Custom Tape W/Leader (Alt: RWR80S8980FSRSL)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas RWR80S8980FSRSL Tape w/Leader 18 Weeks 100
    • 1 -
    • 10 -
    • 100 $27.89
    • 1000 $27.47
    • 10000 $27.19
    Buy Now

    Vishay Intertechnologies RWR89S8980BSB12

    - Bulk (Alt: RWR89S8980BSB12)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas RWR89S8980BSB12 Bulk 12 Weeks 100
    • 1 -
    • 10 -
    • 100 $58.81
    • 1000 $57.93
    • 10000 $57.34
    Buy Now

    Vishay Intertechnologies RWR80S8980FSBSL

    - Bulk (Alt: RWR80S8980FSBSL)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Avnet Americas RWR80S8980FSBSL Bulk 18 Weeks 100
    • 1 -
    • 10 -
    • 100 $27.89
    • 1000 $27.47
    • 10000 $27.19
    Buy Now

    S8980 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    fw300

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    s8980s8981-02s898102s8981+2se-171fw300 PDF

    S1503

    Abstract: 5343
    Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    s8980s10810-11kmpd1123e04s1503+15343 PDF

    dental sensor

    Abstract: S1500 S1502 S8980 S8981-02 CCD 22 pin fax
    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    s8980s8981-02cse-171kmpd1084e03+5dental sensors1500s1502s8981-02ccd 22 pin fax PDF

    Contextual Info: S8980P Linear ICs Crosspoint Switch Circuit status Military/High-RelN Nom. Supp V 5.0 Minimum Operating Temp (øC)-55 Maximum Operating Temp (øC)125 Package StyleDIP Mounting StyleT Pinout Equivalence Code40-22 # Pins40 Ckt. (Pinout) NumberLN04000022 DescriptionDigital Time/Space Switch for Voice/Data


    Original
    s8980pcode40-22pins40numberln04000022 PDF

    DS8980J

    Abstract: DS8980N DS8981J DS8981N J18A N18A DS8981 DS8980
    Contextual Info: Display Drivers DS898Q, DS8981 High Voltage 7-Segment Latches/Decoders/Drivers General Description Features T h e D S8980, DS8981 c ir c u its are c u rre n t- p r o g r a m m a b le s e g m e n t-ra tio e d , 7-se g m e n t gas dis c h a rg e tu b e d is p la y


    OCR Scan
    ds898qds8981ds8980ds8980j+5ds8980nds8981jds8981nj18an18a PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    s8980s8981s7362-01se-171 PDF

    ST14 codec chip

    Abstract: s6802 6802 micro pro 6802 processor S69B
    Contextual Info: Digital Time/Space Crosspoint Switch 7 g o u ld AMI Advanced Product Description •Semiconductors S8980 Features General Description □ ST-BUS Serial Telecom Bus Compatible □ 8-Line x 32-Channel Inputs □ 8-Line x 32-Channel Outputs □ 256 Ports Non-Blocking Switch


    OCR Scan
    s898032-channelst14 codec chips6802+36802 micro pro6802 processors69b PDF

    Contextual Info: , •> Go u l d Digital Time/Space Crosspoint Switch AMI Advanced Product Description * Semiconductors S8980 Features General Description □ ST-BUS Serial Telecom Bus Compatible □ 8-Line x 32-Channel Inputs □ 8-Line x 32-Channel Outputs □ 256 Ports Non-Blocking Switch


    OCR Scan
    s898032-channel PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    s8980s8981s7362-01se-171 PDF

    6802 processor

    Abstract: stm cl-130 S6802 CL-130 STM
    Contextual Info: AMI S8980 STANDARD PRODUCTS Digital Time/Space Crosspoint Switch February 1993 General Description features This VLSI ISO -C M O S device is designed for switching PC M -encoded voice or data, under m icroprocessor control, in a modern digital exchange, PBX or Centrai


    OCR Scan
    s898032-channel6802 processorstm cl-130+2s6802cl-130 stm PDF

    S8981

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    s8980s8981-02cs898honese-171+1s8981 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    s8980s8981s7362-01se-171 PDF

    Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    s8980s10810-11se-171kmpd1123e03 PDF

    dental sensor

    Abstract: S1500 S1502 S7362-01 S8980 S8981 image sensor x-ray dental x-ray sensor
    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    s8980s8981s7362-01se-171+5dental sensors1500s1502image sensor x-raydental x-ray sensor PDF

    pin out mdr 50 pin CONNECTOR

    Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    s8980s10810-11kmpd1123e05pin out mdr 50 pin connector PDF

    Contextual Info: CCD area image sensors S8980 S10810 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 mm,


    Original
    s8980s1081012telephonese-171+1kmpd1123e01 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    s8980s8981-02s898102s8981+1se-171 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    s8980s8981-02s898102s8981+1se-171 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    s8980s8981s7362-01se-171 PDF

    S8980

    Abstract: "Image Sensors" dental sensor S1500 S1502 dental x-ray sensor image sensor x-ray
    Contextual Info: CCD area image sensors S8980 S10810 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5 mm,


    Original
    s8980s10810se-171kmpd1123e02+6image sensorsdental sensors1500s1502dental x-ray sensorimage sensor x-ray PDF

    dental x-ray sensor

    Abstract: S8981-02 S1500 S1502 S8980 S8981 S1503
    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    s8980s8981-02s898102s8981+5se-171dental x-ray sensors1500s1502s1503 PDF

    icdg

    Abstract: S8980
    Contextual Info: DO NOT SCALE DRAWING CAD FILE S8980 IC.DGN SD, 8980- I« DWG- N0-


    OCR Scan
    s8980icdg PDF

    Contextual Info: CCD area image sensors S8980 S10810-11 Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    s8980s10810-11incorporate53b1201+1kmpd1123e06 PDF

    Contextual Info: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    s8980s8981-02cs898honese-171 PDF