Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    S13S14 Search Results

    SF Impression Pixel

    S13S14 Price and Stock

    Select Manufacturer
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bisco Industries BACS13S149C 6,141
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bisco Industries BACS13S149B 386
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    Samtec Inc IDSS-13-S-14.00

    Ribbon Cables / IDC Cables
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Sager IDSS-13-S-14.00
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now
    Master Electronics IDSS-13-S-14.00
    • 1 -
    • 10 $9.74
    • 100 $6.66
    • 1000 $5.07
    • 10000 $5.07
    Buy Now

    Documents mentioning S13S14

    Document Partial File Text Tags Type PDF
    S2NT030 Safety relays - S2 series Base device for
    S2NT030 Safety relays - S2 series Base device for Emergency Stop and Safety Gate applications Equivalent or non-equivalent activation selectable Two-channel activation including cross monitoring and synchronous time check Automatic or Manual Star 3 enabling current paths
    Original PDF
    47c1270
    TOSHIBA (UC/UP) 54E J> m ^0^724^ DOl'iS'i'î 7flfl WËTQS3 T - H9-19-H4 TOSHIBA TMP47C1270/1670/007 CMOS 4-BIT MICROCONTROLLER TM P47C1270N, TMP47C1670N The 47C1270/1670 are the high speed and high performance 4-bit single chip microcomputer with large capacity ROM and RAM, based on the 47C670/870 (TLCS-470 series).
    OCR Scan PDF
    TO SH IB A TMP47C670/870 CMOS 4-Bit
    TO SH IB A TMP47C670/870 CMOS 4-Bit Microcontroller TMP47C670N, TMP47C870N The TMP47C670/870 are high speed and high performance 4-bit single chip micro computers, integrating the 8 bit AD converter, 12-bit programmable pulse generator and high-breakdown voltage outputs based on the
    OCR Scan PDF
    Mounting and Wiring Instructions Interlock
    Mounting and Wiring Instructions Interlock Monitoring Modules (Safety relays) Montage- und Anschlußanleitung Sicherheitsbausteine AZR 31 R2/31T2 Anschlußbilder und Abmessungen/ Connection diagram and dimensions ii i A1 S13 S24 X2 41 13 23 33 m SCH m ERSFIL
    OCR Scan PDF
    msr6r/t
    Safeguarding Applications Guard Locking Interlocks Atlas 5, Bulletin 800, CU2, MSR6R/T, Bulletin 100S, Dual Channel 24V AC/DC, 110V AC, 230V AC L1 L2 L3 Start Momentary Push Button Fuses K1 K2 Lock Release Momentary Push Button Guard Closed Stop Momentary Push Button
    Original PDF
    tmp47c670n
    TOSHIBA TMP47C670/870 CMOS 4-BIT MICROCONTROLLER TMP47C670N, TMP47C870N The 47C670/870 are high speed and high performance 4 -b it single chip micro computers, integrating the 8 b it A/D converter, 12-bit program m able pulse generator and high-breakdow n voltage outputs based on the
    OCR Scan PDF
    Machine Safeguarding Products PREVENTA™ XPS
    Machine Safeguarding Products PREVENTA™ XPS Safety Relays Supplement Catalog 03 File 9007 CONTENTS Description Page Selection Guide… 2-10 General Ratings… 11-12
    Original PDF
    p1hz x1
    Two-hand control unit Up to PL c of EN ISO 13849-1 P1HZ X1 Unit features Safety features ` Positive-guided relay outputs: – 2 safety contacts (N/O), instantaneous ` Connection options for: – 2 operator elements (buttons) ` LED indicator for: – Switch status channel 1/2
    Original PDF
    Safe-Off Option for PowerFlex® 700S Phase II AC
    Safe-Off Option for PowerFlex® 700S Phase II AC Drives and PowerFlex 700L Liquid-Cooled AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and
    Original PDF
    pnoz x3
    E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X3.10P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for:
    Original PDF
    xps-ak
    XPS-AK Module de surveillance pour circuits d'ARRET D'URGENCE et de sécurité selon EN 418 / EN 60204-1 Safety relay for monitoring EMERGENCY STOP and safety circuits according to EN 418 / EN 60204-1 XPS-AK…P Überwachungsbaustein für NOT-AUS und Sicherheitskreise
    Original PDF
    Sicherheitstechnik Not-Aus-Modul BH 5928, BI 5928
    Sicherheitstechnik Not-Aus-Modul BH 5928, BI 5928 mit Zeitverzögerung safemaster 0221625 • BH 5928 Funktionsdiagramm • Taster Ein Not-Aus (Aus) nach der EG-Richtlinie für Maschinen 98/37/EG nach IEC/EN 60 204, EN 954-1
    Original PDF
    steute a SEHfTlEnSFILcompany Safety modules AZR…
    steute a SEHfTlEnSFILcompany Safety modules AZR… Emergency stop relay Safety gate monitor Two-Hand safety relay SAFETY IN SYSTEM: PROTECTION FOR MAN AND MACHINE! Risk analysis System safety: Man and machine protection The machine directive (89/392/EEC) applicable
    OCR Scan PDF
    msr16
    (a) MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after
    Original PDF
    trojan
    Safeguarding Applications Position (Limit) Interlocks 3 x Trojan, Bulletin 800, MSR9R/T, Bulletin 100S, Dual Channel 24V AC/DC, 110V AC, 230V AC Guard Closed 11 21 33 Start Momentary Push Button Trojan Interlock Switch K1 (Aux) K2 (Aux) L1 12 22 L2 L3 34 Stop
    Original PDF
    301an
    Operating instructions Safety-monitoring module SRB 301AN 1 About this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module. The
    Original PDF
    pnoz xv3p
    E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV3P Unit features ` Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 2 safety contacts (N/O), delay-on de-energisation ` Connection options for: – E-STOP pushbutton
    Original PDF
    pnoz x13
    E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X13 Unit features Safety features Safety relay for monitoring E-STOP pushbuttons and safety gates. ` Positive-guided relay outputs: – 5 safety contacts (N/O), instantaneous – 1 auxiliary contact (N/C), instantaneous
    Original PDF
    pnoz xv3
    E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV3.3P Unit features Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals ` Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous – 2 safety contacts (N/O), delay-on
    Original PDF
    minotaur msr6r/t
    See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.
    Original PDF
    azr 31 r2
    10. 10.2 10.2.2 Safety monitoring modules Guard door monitors AZR 31 R2 range to monitor one guard door Features Dimensions 45 x 73.2 x 121 mm Part number Operating voltage Approvals H Z C D* S USA * Under preparation 420 SK4 • Control Category 4 to EN 954-1
    Original PDF
    minotaur
    (a) MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously
    Original PDF