Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    RTD INPUT Search Results

    RTD INPUT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DCL541A01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Datasheet
    DCL541B01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable Datasheet
    DCM341B01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable / AEC-Q100 Datasheet
    DCM341A01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable / AEC-Q100 Datasheet
    TLP385
    Toshiba Electronic Devices & Storage Corporation Photocoupler (phototransistor output), DC input, 5000 Vrms, 4pin SO6L Datasheet

    Documents mentioning RTD INPUT

    Document Partial File Text Tags Type PDF
    cfp-tc-120
    Thermocouple and RTD Modules for Compact FieldPoint NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124 • 8 temperature inputs • Thermocouple or millivolt • 2-, 3-, or 4-wire RTD • Built-in signal conditioning between channels • 250 V common-mode isolation
    Original PDF
    adam-6015
    B&B ELECTRONICS PRODUCT INFORMATION Integrate – Expand – Simplify ADAM-6015 - 0704 - 1/2 Model ADAM-6015 Multi-Monitor Up to 7 RTD Sensor Types 7-Channel RTD Input Module Overview The ADAM-6015 7-channel RTD input module accepts a wide range of RTD sensor types, including Pt100, Pt1000,
    Original PDF
    SCM5B35 Linearized 4-Wire RTD Input Modules
    SCM5B35 Linearized 4-Wire RTD Input Modules FEATURES Each SCM5B35 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high level analog voltage output. This voltage output is logic switch controlled,
    Original PDF
    SCT1P34 Linearized 2- or 3-Wire RTD Input
    SCT1P34 Linearized 2- or 3-Wire RTD Input Transmitters FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDs Each SCT1P34 RTD input transmitter provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a process
    Original PDF
    adm220
    AMEliEO 'y m SIGNAL SIGN, CONDITIONING ADM220 RTD Transmitter ★ Suitable for BS1904 2,or 3 Wire RTD Supply Voltages 115Vac ± 20% 240Vac ± 20% 24Vdc ± 2-5V RFI Protection to IEC801-3 available Amelec Standard 10 year guarantee WIRING RTD Input
    OCR Scan PDF
    rtd input
    4-channel Isolated RTD Input Module Specifications Analog Input 4 16 bits, 10 samples/sec., 12 bits, 100 samples/sec. (optional) Input type Pt and Ni RTD RTD type and Type Range ∂ temperature ranges Pt100 -100˚C ~ 100˚C 0.00385 Pt100 0˚C ~ 100˚C 0.00385
    Original PDF
    sc-2042
    SC-2042-RTD 8-Channel RTD Signal Conditioning Accessory SC-2042-RTD 8 inputs for mixed signal types RTDs –4, 3, or 2-wire (differential) Thermistors (to 8.5 kΩ) Millivolt and volt sources 8 independent current excitation sources Direct connection to DAQ products
    Original PDF
    sc-2042-rtd
    8-Channel RTD Signal Conditioning Accessory SC-2042-RTD SC-2042-RTD Features 8 inputs for mixed signal types RTDs – 4, 3, or 2-wire (differential) Thermistors (to 8.5 kΩ) Millivolt and volt sources 8 independent current excitation sources Direct connection to DAQ products
    Original PDF
    q116
    ACTIONI/Q® Q116 RTD Input Limit Alarm Provides Relay Contact Closures at a Preset RTD Input Level Description Benefits The ActionI/Q model Q116 is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint
    Original PDF
    fp-rtd-122
    8-Channel RTD Input Module FP-RTD-122 8 RTD or resistance inputs 100 Ω and 1000 Ω Pt RTDs Resistance up to 4000 Ω 16-bit resolution Self-calibrating with stable onboard reference Rejection of 50/60 Hz noise Isolated input-output 3,000 Vrms isolation
    Original PDF
    ad10t2
    I/O MODULES STANDARD ANALOG INPUT DATA SHEET Form 444-010201 Description page 1/2 Part Numbers Description AD10T2 100 Ohm RTD Input Isolated AD14T 10 Ohm RTD Input Isolated The AD10T2 and AD14T modules provide a single channel of optically-isolated RTD temperature-to-digital conversion with
    Original PDF
    dsca34
    DSCA34 Linearized 2- or 3-Wire RTD Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDs Each DSCA34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high level voltage
    Original PDF
    g418-0001
    ULTRA SLIMPAK® G418-0001 RTD Input Field Configurable Isolator Provides an Isolated, Linearized DC Output in Proportion to an RTD Input Description Benefits The Ultra SlimPak G418 is a DIN rail mount, RTD input signal conditioner with 1800VDC isolation between input, output and power. The field configurable input and output offers flexible, wide
    Original PDF
    scm7b34/34n
    SCM7B34/34N Isolated Linearized 2- Or 3-Wire RTD Input Modules FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDS Each SCM7B34/34N RTD input module accepts a single channel of 100Ω Platinum (α = 0.00385) or 120Ω Nickel (α = 0.00672) RTD input and
    Original PDF
    xtr105
    ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation
    Original PDF
    IB IL TEMPCON RTD IB IL TEMPCON RTD-PAC Inline
    IB IL TEMPCON RTD IB IL TEMPCON RTD-PAC Inline Multi-Channel Temperature Controller for Resistance Thermometers Data Sheet 6486BC01 6 4 8 6 B 0 0 0 11/2002 The IB IL TEMPCON RTD and IB IL TEMPCON RTD-PAC only differ in the scope of supply (see "Ordering Data" on page 19). Their function and
    Original PDF
    8942
    Models 8940, 8941, 8942 Isolated RTD to Voltage MODEL 8940, 8941, 8942 RTD CONNECTIONS MODEL 89XX CASE DIMENSIONS Model Input Temperature Range Output A 8940-450-DC 8941-450-DC 100 Ohm 500 Ohm Platinum RTD α = 0.00385, 2 or 3 Wire 8942-450-DC 1000 Ohm -50°C to +450°C
    Original PDF
    xtr105
    ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation
    Original PDF