RTD INPUT Search Results
RTD INPUT Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DCL541A01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable | Datasheet | ||
| DCL541B01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable | Datasheet | ||
| DCM341B01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable / AEC-Q100 | Datasheet | ||
| DCM341A01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable / AEC-Q100 | Datasheet | ||
| TLP385 | Toshiba Electronic Devices & Storage Corporation | Photocoupler (phototransistor output), DC input, 5000 Vrms, 4pin SO6L | Datasheet |
Documents mentioning RTD INPUT
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| cfp-tc-120 | Thermocouple and RTD Modules for Compact FieldPoint NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124 • 8 temperature inputs • Thermocouple or millivolt • 2-, 3-, or 4-wire RTD • Built-in signal conditioning between channels • 250 V common-mode isolation |
Original | ||||
| adam-6015 | B&B ELECTRONICS PRODUCT INFORMATION Integrate – Expand – Simplify ADAM-6015 - 0704 - 1/2 Model ADAM-6015 Multi-Monitor Up to 7 RTD Sensor Types 7-Channel RTD Input Module Overview The ADAM-6015 7-channel RTD input module accepts a wide range of RTD sensor types, including Pt100, Pt1000, |
Original | ||||
| SCM5B35 Linearized 4-Wire RTD Input Modules | SCM5B35 Linearized 4-Wire RTD Input Modules FEATURES Each SCM5B35 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high level analog voltage output. This voltage output is logic switch controlled, |
Original | ||||
| SCT1P34 Linearized 2- or 3-Wire RTD Input | SCT1P34 Linearized 2- or 3-Wire RTD Input Transmitters FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDs Each SCT1P34 RTD input transmitter provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a process |
Original | ||||
| adm220 | AMEliEO 'y m SIGNAL SIGN, CONDITIONING ADM220 RTD Transmitter ★ Suitable for BS1904 2,or 3 Wire RTD Supply Voltages 115Vac ± 20% 240Vac ± 20% 24Vdc ± 2-5V RFI Protection to IEC801-3 available Amelec Standard 10 year guarantee WIRING RTD Input |
OCR Scan | ||||
| rtd input | 4-channel Isolated RTD Input Module Specifications Analog Input 4 16 bits, 10 samples/sec., 12 bits, 100 samples/sec. (optional) Input type Pt and Ni RTD RTD type and Type Range ∂ temperature ranges Pt100 -100˚C ~ 100˚C 0.00385 Pt100 0˚C ~ 100˚C 0.00385 |
Original | ||||
| sc-2042 | SC-2042-RTD 8-Channel RTD Signal Conditioning Accessory SC-2042-RTD 8 inputs for mixed signal types RTDs –4, 3, or 2-wire (differential) Thermistors (to 8.5 kΩ) Millivolt and volt sources 8 independent current excitation sources Direct connection to DAQ products |
Original | ||||
| sc-2042-rtd | 8-Channel RTD Signal Conditioning Accessory SC-2042-RTD SC-2042-RTD Features 8 inputs for mixed signal types RTDs – 4, 3, or 2-wire (differential) Thermistors (to 8.5 kΩ) Millivolt and volt sources 8 independent current excitation sources Direct connection to DAQ products |
Original | ||||
| q116 | ACTIONI/Q® Q116 RTD Input Limit Alarm Provides Relay Contact Closures at a Preset RTD Input Level Description Benefits The ActionI/Q model Q116 is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint |
Original | ||||
| fp-rtd-122 | 8-Channel RTD Input Module FP-RTD-122 8 RTD or resistance inputs 100 Ω and 1000 Ω Pt RTDs Resistance up to 4000 Ω 16-bit resolution Self-calibrating with stable onboard reference Rejection of 50/60 Hz noise Isolated input-output 3,000 Vrms isolation |
Original | ||||
| ad10t2 | I/O MODULES STANDARD ANALOG INPUT DATA SHEET Form 444-010201 Description page 1/2 Part Numbers Description AD10T2 100 Ohm RTD Input Isolated AD14T 10 Ohm RTD Input Isolated The AD10T2 and AD14T modules provide a single channel of optically-isolated RTD temperature-to-digital conversion with |
Original | ||||
| dsca34 | DSCA34 Linearized 2- or 3-Wire RTD Input Signal Conditioners FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDs Each DSCA34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high level voltage |
Original | ||||
| g418-0001 | ULTRA SLIMPAK® G418-0001 RTD Input Field Configurable Isolator Provides an Isolated, Linearized DC Output in Proportion to an RTD Input Description Benefits The Ultra SlimPak G418 is a DIN rail mount, RTD input signal conditioner with 1800VDC isolation between input, output and power. The field configurable input and output offers flexible, wide |
Original | ||||
| scm7b34/34n | SCM7B34/34N Isolated Linearized 2- Or 3-Wire RTD Input Modules FEATURES DESCRIPTION ● INTERFACES TO 100Ω PLATINUM OR 120Ω NICKEL RTDS Each SCM7B34/34N RTD input module accepts a single channel of 100Ω Platinum (α = 0.00385) or 120Ω Nickel (α = 0.00672) RTD input and |
Original | ||||
|
|
||||||
| xtr105 | ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation |
Original | ||||
| IB IL TEMPCON RTD IB IL TEMPCON RTD-PAC Inline | IB IL TEMPCON RTD IB IL TEMPCON RTD-PAC Inline Multi-Channel Temperature Controller for Resistance Thermometers Data Sheet 6486BC01 6 4 8 6 B 0 0 0 11/2002 The IB IL TEMPCON RTD and IB IL TEMPCON RTD-PAC only differ in the scope of supply (see "Ordering Data" on page 19). Their function and |
Original | ||||
| 8942 | Models 8940, 8941, 8942 Isolated RTD to Voltage MODEL 8940, 8941, 8942 RTD CONNECTIONS MODEL 89XX CASE DIMENSIONS Model Input Temperature Range Output A 8940-450-DC 8941-450-DC 100 Ohm 500 Ohm Platinum RTD α = 0.00385, 2 or 3 Wire 8942-450-DC 1000 Ohm -50°C to +450°C |
Original | ||||
| xtr105 | ® FOUR-WIRE RTD CURRENT-LOOP TRANSMITTER: Four-Wire Connections to an RTD Allow the RTD to be Remotely Located from Active Circuitry, Yet Maintain Accuracy by David Jones, and Mark Stitt XTR105 is an application-specific IC containing onboard transducer excitation, signal conditioning instrumentation |
Original | ||||