RS485 MOD Search Results
RS485 MOD Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 471-1045-100 | Amphenol Communications Solutions | Plug mod,10Positions, 4.5mm, NEXLEV | |||
| 471-2095-100 | Amphenol Communications Solutions | Plug mod,20Positions, 9.5mm, NEXLEV | |||
| 471-5065-100 | Amphenol Communications Solutions | Plug mod,25Positions, 6.5mm, NEXLEV | |||
| 470-1205-100 | Amphenol Communications Solutions | Receptacle. mod,10Positions, 20.5mm, NEXLEV | |||
| 470-2205-100 | Amphenol Communications Solutions | Receptacle. mod,20Positions, 20.5mm, NEXLEV |
RS485 MOD Price and Stock
Select Manufacturer
Olimex MOD-RS485Interface Development Tools RS485 CONVERTER MOD W/ UEXT CONN |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MOD-RS485 | 27 |
|
Buy Now | |||||||
Amphenol Corporation RS485-CONVERSION-MODSensor Hardware & Accessories RS485 to 4-20mA Analog Conversion Module for NH3-500-Probe |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
RS485-CONVERSION-MOD | 20 |
|
Buy Now | |||||||
Olimex MOD-RS485-ISODaughter Cards & OEM Boards RS485 CONVERTER GALV ISO WITH UEXT |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MOD-RS485-ISO |
|
Get Quote | ||||||||
Bourns Inc SSD-250A-RCurrent Sensors - Industrial SSD-250A-R CURRENT SENSOR - RS-485/MODBUS Interface |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
SSD-250A-R | Each | 5 | 1 |
|
Buy Now | |||||
Documents mentioning RS485 MOD
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 146 74 EMDX³ AMS N192515/00 Module d’options : | 146 74 EMDX³ AMS N192515/00 Module d’options : mémoire RS485 pour 146 69 Optional module: RS485 memory for 146 69 Optionsmodul: Speicher RS485 für 146 69 Modulo di opzioni: memoria RS485 per 146-69 Optionele modules: RS485 geheugen voor 146 69 Módulo de opciones: memoria RS485 para 146 69 |
Original | ||||
| n292 | 146 71 EMDX³ MI N292512/00 Module option communication RS485 pour 146 68 Module with RS485 communication option for 146 68 Modul mit Kommunikationsoption RS485 für 146 68 Modulo opzione comunicazione RS485 per 146 68 Module met communicatie optie RS485 voor 146 68 |
Original | ||||
| ltc1481 | RS485 Interface Solutions RS485 Family Features ■ Ultralow Power ■ CMOS Schottky Process ■ Designed for RS485 and RS422 Applications ■ Three-State RS485 Outputs When Shut Down ■ Power-Up/Down Glitch Free Outputs ■ Power-Saving Shutdown Mode (LTC1481, |
OCR Scan | ||||
| Features Four RS232 and Two RS485 Transceivers 3V | Features Four RS232 and Two RS485 Transceivers 3V to 5.5V Supply Voltage 20Mbps RS485 and 500kbps RS232 Automatic Selection of Integrated RS485 (120Ω) and RS232 (5kΩ) Termination Resistors Half-/Full-Duplex RS485 Switching Logic Loopback Mode High ESD: ±16kV on Line I/O |
Original | ||||
| RS485 Interface Solutions RS485 Family Features ■ | RS485 Interface Solutions RS485 Family Features ■ The LTC RS485 Advantage: Low Power Ultra-Low Power CMOS Schottky Process Designed for RS485 and RS422 Applications Three-State RS485 Outputs When Shut Down Power-Up/Down Glitch Free Outputs |
OCR Scan | ||||
| ltc2870 | LTC2870/LTC2871 RS232/RS485 Multiprotocol Transceivers with Integrated Termination DESCRIPTION FEATURES n n n n n n n n n n n One RS485 and Two RS232 Transceivers 3V to 5.5V Supply Voltage 20Mbps RS485 and 500kbps RS232 Automatic Selection of Integrated RS485 (120Ω) |
Original | ||||
| lt1791 | advertisement RS485 Transceivers Sustain ± 60V Faults – Design Note 203 Gary Maulding Introduction The LT®1785 and LT1791 RS485/RS422 transceivers with ±60V fault tolerance solve a real-world problem of field failures in typical RS485 interface circuits. Modems |
Original | ||||
| ltc1321 | LTC1321/LTC1322/LTC1335 RS232/EIA562/RS485 Transceivers U DESCRIPTIO FEATURES ■ LTC1321: 2-EIA562/RS232 Transceivers/2-RS485 Transceivers LTC1322: 4-EIA562/RS232 Transceivers/2-RS485 Transceivers LTC1335: 4-EIA562 Transceivers/2-RS485 |
Original | ||||
| pvi-rs485-modbus | Solar inverters ABB monitoring and communications PVI-RS485-MODBUS Converter PVI-RS485-MODBUS is the ABB devices family able to convert the proprietary Aurora Protocol to ModBus RTU or ModBus TCP communication protocol. The PVI-RS485-MODBUS enables ABB inverters to exchange data with third |
Original | ||||
| LTC1535 Isolated RS485 Transceiver U DESCRIPTIO | LTC1535 Isolated RS485 Transceiver U DESCRIPTIO FEATURES ■ The LTC®1535 is an isolated RS485 full-duplex differential line transceiver. Isolated RS485 is ideal for systems where the ground loop is broken to allow for much larger common mode voltage ranges. An internal capacitive isolation |
Original | ||||
| ltc1535 | LTC1535 Isolated RS485 Transceiver FEATURES DESCRIPTION n The LTC®1535 is an isolated RS485 full-duplex differential line transceiver. Isolated RS485 is ideal for systems where the ground loop is broken to allow for much larger common mode voltage ranges. An internal capacitive isolation barrier |
Original | ||||
| PSM-ME-RS485/RS485-P Repeater for RS-485 2-wire | PSM-ME-RS485/RS485-P Repeater for RS-485 2-wire bus systems 1. Short Description The rail-mountable and compact RS-485 repeater, PSM-ME-RS485/RS485-P, was specially developed for the high demands for use in fieldbus systems. The device is snapped onto standard EN mounting rails in |
Original | ||||
| ltc1535 | LTC1535 Isolated RS485 Transceiver U DESCRIPTIO FEATURES ■ The LTC®1535 is an isolated RS485 full-duplex differential line transceiver. Isolated RS485 is ideal for systems where the ground loop is broken to allow for much larger common mode voltage ranges. An internal capacitive isolation |
Original | ||||
| rs485-p | PSM-ME-RS485/RS485-P Repeater for RS-485 2-wire bus systems 1. Short Description The rail-mountable and compact RS-485 repeater, PSM-ME-RS485/RS485-P, was specially developed for the high demands for use in fieldbus systems. The device is snapped onto standard EN mounting rails in |
Original | ||||
|
|
||||||
| ltc1535 | LTC1535 Isolated RS485 Transceiver U DESCRIPTIO FEATURES ■ The LTC®1535 is an isolated RS485 full-duplex differential line transceiver. Isolated RS485 is ideal for systems where the ground loop is broken to allow for much larger common mode voltage ranges. An internal capacitive isolation |
Original | ||||
| LTC1535 Isolated RS485 Transceiver U DESCRIPTIO | LTC1535 Isolated RS485 Transceiver U DESCRIPTIO FEATURES ■ The LTC®1535 is an isolated RS485 full-duplex differential line transceiver. Isolated RS485 is ideal for systems where the ground loop is broken to allow for much larger common mode voltage ranges. An internal capacitive isolation |
Original | ||||
| lt1785 | DESIGN FEATURES LT1785 and LT1791: 60V, Fault-Tolerant RS485/RS422 Transceivers by Gary Maulding Introduction The LT1785 and LT1791 RS485/ RS422 transceivers with ±60V fault tolerance solve a real-world problem of field failures in RS485 interface circuits. RS485 and RS422 data networks are used in a wide variety of |
Original | ||||
| ltc1480 | LTC1480 3.3V Ultralow Power RS485 Transceiver U FEATURES DESCRIPTIO ■ The LTC®1480 is an ultralow power differential line transceiver which provides full RS485 compatibility while operating from a single 3.3V supply. It is designed for data transmission standard RS485 applications with extended |
Original | ||||
| ltm2881 | DEMO MANUAL DC1746A LTM2881: Isolated RS485/RS422 µModule Transceiver + Power DESCRIPTION Demonstration circuit 1746A is an isolated RS485/RS422 μModule® transceiver + power featuring the LTM®2881. The demo circuit is a 2500VRMS galvanically isolated RS485/RS422 transceiver interface. The demo circuit |
Original | ||||