ROTRON AG Search Results
Documents mentioning ROTRON AG
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| sd24b5-e2 | SPECIFICATIONS Model Number: Part Number: SD24B5-E2 039029 October 11, 2002 nH yy COMAIR ROTRON Mechanical Drawing: Motor: Nominal Voltage Operating Voltage Range Nominal Running Current Locked Rotor Current Running Power Average Speed Bearings Air Flow Acoustic |
OCR Scan | ||||
| SPECIFICATIONS Model Number: Part Number: GL12S4H | SPECIFICATIONS Model Number: Part Number: GL12S4H 032877 Q2 COMAIR ROTRON Mechanical Drawing: TACHOMETER OUTPUT WAVE FORM ^ L_ - * | *0 * [*_ •AMPLITUDES U P TO NOMINAL OPERATING VOLTAGE OR O P E N C O tlE C T O R AVAILABLE CONSULT APPLICATION ENGINEERING |
OCR Scan | ||||
| ametek | Ametek, Inc. Rotron Technical Products Division 627 Lake Street Kent, Ohio 44240 User's Guide Number 4930720 Revision E 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2" (183 mm) Windjammer Products June 2000 |
Original | ||||
| comair rotron | nn SPECIFICATIONS Model Number: Part Number: (À W T12B3 031101 A pril 5, 2002 COMAIR ROTRON Mechanical Drawing: Motor: Nominal Voltage Operating Voltage Range Nominal Running Current Max. Locked Rotor Current Running Power Average Speed Bearings Air Flow |
OCR Scan | ||||
| 03284 | SPECIFICATIONS Model Number: Part Number: Da 0 2 GL24S4H 032842 COMAIR ROTRON Mechanical Drawing: Motor: Additional Features: Nominal Voltage = 24 VDC Operating Voltage Range = 1 2 - 2 4 VDC Nominal Running Current @ 25 C = .625 A Locked Rotor Current @ 25 C |
OCR Scan | ||||
| nn 10(à SPECIFICATIONS Model Number: Part Number: | nn 10(à SPECIFICATIONS Model Number: Part Number: MX2B3 028422 June 27, 2002 C 0M A IR ROTRON Mechanical Drawing: .173 DIA x .350 DEEP 4.39 8.89 2 PLACES (AS SHOWN AND 180° FAR SIDE) USE # 1 0 -3 2 TYPE “ F” SELF TAPPING SCREW FOR GROUND CONNECTION. |
OCR Scan | ||||
| ○ B R U S H L E S S D C M OTO R S • B L OW E R S | ○ B R U S H L E S S D C M OTO R S • B L OW E R S • C O N T R O L L E R S ○ WE’RE BIG ON BRUSHLESS TM ○ |
Original | ||||
| blower | 5.7” (145mm) BLDC Thru Flow Blower Blower Data 400 WATT, 240 VOLT Part Number Standard Flow Unit of Measure 117629 E* Stages 117630 E* 1 2 Vacuum, Max. (Sealed Vacuum) in. H2O 28 47 mBar 69 117 Pressure, Max. (Sealed Pressure) in. H2O 31 50 mBar 77 124 Flow Rate, Max. (Open Flow) |
Original | ||||
| blower | 5.7” (145mm) DC Bypass Blower Blower Data Unit of Measure 1200 WATT, 240 VOLT Part Number High Flow Standard Flow Ultra Flow 117416 M* 119152 M* 119154 M* 117415 E* 119151 E* 119153 E* 119155 E* 1 50 2 91 1 33 Stages Vacuum, Max. (Sealed Vacuum) in. H2O |
Original | ||||
| blower | 5.7” (145mm) BLDC Bypass Blower 400 WATT, 240 VOLT Part Number Blower Data Unit of Measure Stages Standard Flow High Flow 117634 M* 117633 M 117632 M* 117637 M* 117636 M* 117635 M* 117640 E* 117639 E 117638 E* 117643 E* 117642 E* 117641 E* 1 2 3 1 2 3 Vacuum, Max. (Sealed Vacuum) |
Original | ||||
| tp-118 | RETURN TO MENU TP-118 Power Tube Application Note Application Guide for Forced-Air Cooling of BURLE Power Tubes Foreword BURLE INDUSTRIES, INC., has prepared this booklet to emphasize those considerations important for effective forced-aircooling of BURLE power tubes. It will help the equipment and |
Original | ||||
| TransGuard ® APPLICATION NOTES • SMT Process | TransGuard ® APPLICATION NOTES • SMT Process Characteristics of AVX TransGuards • IEC 1000-4 Requirements • Turn On Time Characteristics of AVX Multilayer Varistors • The Impact of ESD on Insulated Portable Equipment • AVX TransGuard Motor and Relay Application Study |
Original | ||||
| TransGuard APPLICATION NOTES • AVX Multilayer | TransGuard APPLICATION NOTES • AVX Multilayer Varistors – Assembly Guidelines • IEC 61000-4 Requirements • Turn On Time Characteristics of AVX Multilayer Varistors • The Impact of ESD on Insulated Portable Equipment • AVX TransGuard Motor and Relay Application Study |
Original | ||||
| AN3 Solid-State Temperature Sensors Author: | AN3 Solid-State Temperature Sensors Author: dependent element, voltage reference, two comparators, control flip-flop, and push-pull digital outputs in a single CMOS integrated circuit. Set point temperatures are selected with external resistors. The temperature dependent element is a Positive Temperature |
Original | ||||
|
|
||||||
| Return To Product Page 7649 Power Tube Beam Power | Return To Product Page 7649 Power Tube Beam Power Tube • CERMOLOX® Ruggedized 4.5 kW Peak Output at 1215 MHz Matrix-Type Cathode Forced-Air Cooled BURLE 7649 is a very small, forced-air-cooled, UHF beam power tube designed for applications in which |
Original | ||||
| TransGuard ® APPLICATION NOTES • AVX Multilayer | TransGuard ® APPLICATION NOTES • AVX Multilayer Varistors – Assembly Guidelines • IEC 61000-4 Requirements • Turn On Time Characteristics of AVX Multilayer Varistors • The Impact of ESD on Insulated Portable Equipment • AVX TransGuard® Motor and |
Original | ||||
| an762 | M AN762 Applications of the TC62X Solid-State Temperature Sensors Author: Wes Freeman Microchip Technology Inc. option (i.e. to turn on a fan at the high limit) and an ‘H’, or Heat, option (i.e. to keep a heater on until the high limit is reached). INTRODUCTION |
Original | ||||
| bmod0063 | USER MANUAL Maxwell Technologies® BOOSTCAP® Energy Storage Modules for Heavy Duty Transportation Applications User Manual for 125 V Modules: BMOD0063 P125 B11 21 (revision 2.1) BMOD0063 P125 B21 21 (revision 2.1) WARNING DANGER – HIGH VOLTAGE HAZARD! |
Original | ||||
| LiquiFlo 1.5 AC Power Modules Hardware Reference, | LiquiFlo 1.5 AC Power Modules Hardware Reference, Installation, and Troubleshooting Version 1.2 Instruction Manual D2-3494-1 The information in this manual is subject to change without notice. Throughout this manual, the following notes are used to alert you to safety considerations: |
Original | ||||
| CrouzetMotors.book Page 145 Wednesday, July 7, | CrouzetMotors.book Page 145 Wednesday, July 7, 2004 2:51 PM Fans 4 Products and specifications subject to change without notice. Order/Technical Support - Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 4/145 CrouzetMotors.book Page 146 Wednesday, July 7, 2004 2:51 PM |
Original | ||||