RELAY RXM Search Results
RELAY RXM Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DS3680D | Texas Instruments | Quad Telephone Relay Drivers 14-SOIC 0 to 70 |
|
|
|
| ULN2003LVPWR | Texas Instruments | Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 |
|
|
|
| ULN2003V12PWR | Texas Instruments | Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 |
|
|
|
| ULN2003LVDR | Texas Instruments | Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 |
|
|
|
| DS3680DE4 | Texas Instruments | Quad Telephone Relay Drivers 14-SOIC 0 to 70 |
|
|
Documents mentioning RELAY RXM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Jnta-No. INFORMATION EX 642-300 E RFR, November | Jnta-No. INFORMATION EX 642-300 E RFR, November 1981 Edition 3 7453 froiW D fiW Fieg, Page 1 Motor Protection Type RAMPA List of contents Section Title Page 1 2 3 4 5 6 GENERAL INPUT CIRCUITRY OVERLOAD RELAY OVERCURRENT RELAY EAH.TH-MULT RELAY NEGATIVE SEQUENCE RELAY |
OCR Scan | ||||
| rxih 2 | Info-N o. ASEA INFORMATION RK 413-300 E From /D ate Reg. Relay Division RFR, April 1970 Edition 1 5623 Page 1 Over-current relay type RXIH 2 Over-current relay RXIH 2 OUTSTANDING FEATURES • is built-up of static components • has out-put matched for a separate output relay |
OCR Scan | ||||
| rxmt | m u i » ABBRe,ays ASEA B R O W N BOVERI Abstract v Type RXMT 1 Dual high-speed relay, 2 contacts The RXMT 1 dual high-speed relay is generally used where a reliable high-speed, light-duty re lay is needed. The relay is recommended where highly corrosive or polluted atmospheric condi |
OCR Scan | ||||
| ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3 | ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3 1 -3 0 0 pE6 RFR, Cían 19S1 Edition 2 5633 1 S tatic auxiliary relay type RXMEA 1 o Used as fast acting bounce free trip relay o O perates for a d.c. input voltage of 8 to 30 V o Operating tim e maximum 1 ms |
OCR Scan | ||||
| Transient measuring directional relay and | Transient measuring directional relay and earth-fault protection RXPG 1MRK 509 012-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970172) Features Relay • Transient measuring directional earth fault relay for resonant earthed systems |
Original | ||||
| rxide | Catalogue RK 47-10 E ASEA Edition 1 January 1972 File R, Part 1 Time-lag over-current relay îc ïô I m ïb TT type RXIDE 4 'iFjjjEjxP ® Registered trade mark Page Time-lag over-current relay type RXIDE 4 (81674) 2 2 co oo Relay p rotection incorporating tim e-lag over-current relay type RXIDE 4 mounted on a frame (81687 |
OCR Scan | ||||
| rxeda relay | Time-overvoltage relay and protection assemblies RXEDA 1 and RAEDA 1MRK 509 044-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970888) Features RXEDA relay • Microprocessor based time-overvoltage relay for DC and AC, single- or three-phase |
Original | ||||
| radsb | Catalogue RK 62-12 E Edition 2 1981-09 File R, part 1 T ransformer differential relay type RADSB The RADSB is a three-phase percentage differential relay with two, three or five through-fag[[ restraint inputs. The relay can b& used for the protection of duel-win ding or multi-windIng transformers which are provided with one or more circuitbreakers for each winding. TTie relay is available in different |
OCR Scan | ||||
| raaak | ASEA Relay Division Info-No. INFORMATION RK 851-300 From/Date Reg. RFR, September 1972 Edition 1 5651 E Page 1 Relay equipment type RAAAK for single-phase and three-phase auto-reclosing of high voltage circuit-breakers GENERAL The relay equipment for single-phase and three-phase auto |
OCR Scan | ||||
| zelio relay | Plug-in relays Zelio Relay Catalogue January 06 Contents Zelio Relay - plug-in relays 1 Selection guide…page 2 RSB interface relays b Presentation, characteristics… pages 4 and 5 |
Original | ||||
| transformer differential relay | ASEA Catalogue RK 62-10 E Edition 4 Januaryl07S File R, Part 1 Transformer differential relay type RADSE RADSE is a static, transform er diffe re n tial relay w ith outstanding speed, sensi t i v i ty a n tJ secu rity, O nly o ns relay is req u ired to protect the three phases o f a |
OCR Scan | ||||
| asea | Al lili **IPIP ASEA B R O W N BOVERI ABB Relays Over- or under-frequency relay assem blies ( T r r \ ^ I r r y Abstract Application • Wide setting ranges, 50 Hz relay: 44.41 -50 .7 3 Hz or 44.41-59.15 Hz 60 Hz relay: 53.07-60.62 Hz or 53.07-70.68 Hz • Settings in steps w ith the resolution, |
OCR Scan | ||||
| Compact current relay and protection assemblies | Compact current relay and protection assemblies RXHL 401 and RAHL 401 1MRK 509 062-BEN Page 1 Issued: February 2000 Status: New Data subject to change without notice Features Three phase compact current relay for: • Phase overcurrent protection, three stages |
Original | ||||
| rxmda | H H a sea in f o r m a t io n RFR 1159 E Thermally delayed auxiliary relay type RXMDA Reg. >633 RELAY DESCRIPTION This is a preliminary description based on information to be included in Catalogue RK 21-11 E. • Time-lag on pick up 4-5 Seconds • 2-6 contacts |
OCR Scan | ||||
|
|
||||||
| mk50h28 | MK50H28 ® MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol |
Original | ||||
| mk50h28 | MK50H28 MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol |
Original | ||||
| mk50h28 | MK50H28 ® MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol |
Original | ||||
| reverse power relay | ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current |
OCR Scan | ||||
| 049-ben | Compact current relay and protection assemblies RXHL 411 and RAHL 411 1MRK 509 049-BEN Page 1 Issued: January 2000 Status: New Data subject to change without notice Features Three phase compact current relay for: • Phase overcurrent protection, three stages |
Original | ||||
| mk50h28 | MK50H28 MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol |
Original | ||||
| distance relay | A 3 E A RF 615 026 Distance relay type RAZOG using healthy phase voltages or memory voltage for directional measurement__________ General The standard design of distance relay type RAZOG uses the voltage of the faulted phase/s for directional measurement. |
OCR Scan | ||||
| rxmm 1 | J& l i I I #*IPIP A SE A B R O W N BOVERI Type RXMM 1 Dual auxiliary relay, 4 or 6 contacts B03-1212E Page 1 Ju n e 30, 1982 Data subject to ch a n g e without noticc ABB Relays Abstract • Self-reset • D C voltage operated • 2 relay units per module |
OCR Scan | ||||
| mk50h28 | MK50H28 MULTI LOGICAL LINK FRAME RELAY CONTROLLER ADVANCE DATA SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent (or no LMI/LIV Protocol |
Original | ||||
| overcurrent relay | Thermal overcurrent relay and protection assemblies RXVK 2H and RAVK 1MRK 509 003-BEN Page 1 Issued January 2004 Revision: A Data subject to change without notice (SE970118) (SE970139) Features • Thermal overcurrent relay with the same time constants for heating and cooling. |
Original | ||||