    RELAY RXM Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DS3680D
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy
    ULN2003LVPWR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    ULN2003V12PWR
    Texas Instruments Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 Visit Texas Instruments Buy
    ULN2003LVDR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    DS3680DE4
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy

    Documents mentioning RELAY RXM

    Document Partial File Text Tags Type PDF
    Jnta-No. INFORMATION EX 642-300 E RFR, November
    Jnta-No. INFORMATION EX 642-300 E RFR, November 1981 Edition 3 7453 froiW D fiW Fieg, Page 1 Motor Protection Type RAMPA List of contents Section Title Page 1 2 3 4 5 6 GENERAL INPUT CIRCUITRY OVERLOAD RELAY OVERCURRENT RELAY EAH.TH-MULT RELAY NEGATIVE SEQUENCE RELAY
    OCR Scan PDF
    rxih 2
    Info-N o. ASEA INFORMATION RK 413-300 E From /D ate Reg. Relay Division RFR, April 1970 Edition 1 5623 Page 1 Over-current relay type RXIH 2 Over-current relay RXIH 2 OUTSTANDING FEATURES • is built-up of static components • has out-put matched for a separate output relay
    OCR Scan PDF
    rxmt
    m u i » ABBRe,ays ASEA B R O W N BOVERI Abstract v Type RXMT 1 Dual high-speed relay, 2 contacts The RXMT 1 dual high-speed relay is generally used where a reliable high-speed, light-duty re­ lay is needed. The relay is recommended where highly corrosive or polluted atmospheric condi­
    OCR Scan PDF
    ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3
    ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3 1 -3 0 0 pE6 RFR, Cían 19S1 Edition 2 5633 1 S tatic auxiliary relay type RXMEA 1 o Used as fast acting bounce free trip relay o O perates for a d.c. input voltage of 8 to 30 V o Operating tim e maximum 1 ms
    OCR Scan PDF
    Transient measuring directional relay and
    Transient measuring directional relay and earth-fault protection RXPG 1MRK 509 012-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970172) Features Relay • Transient measuring directional earth fault relay for resonant earthed systems
    Original PDF
    rxide
    Catalogue RK 47-10 E ASEA Edition 1 January 1972 File R, Part 1 Time-lag over-current relay îc ïô I m ïb TT type RXIDE 4 'iFjjjEjxP ® Registered trade mark Page Time-lag over-current relay type RXIDE 4 (81674) 2 2 co oo Relay p rotection incorporating tim e-lag over-current relay type RXIDE 4 mounted on a frame (81687
    OCR Scan PDF
    rxeda relay
    Time-overvoltage relay and protection assemblies RXEDA 1 and RAEDA 1MRK 509 044-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970888) Features RXEDA relay • Microprocessor based time-overvoltage relay for DC and AC, single- or three-phase
    Original PDF
    radsb
    Catalogue RK 62-12 E Edition 2 1981-09 File R, part 1 T ransformer differential relay type RADSB The RADSB is a three-phase percentage differential relay with two, three or five through-fag[[ restraint inputs. The relay can b& used for the protection of duel-win ding or multi-windIng transformers which are provided with one or more circuitbreakers for each winding. TTie relay is available in different
    OCR Scan PDF
    raaak
    ASEA Relay Division Info-No. INFORMATION RK 851-300 From/Date Reg. RFR, September 1972 Edition 1 5651 E Page 1 Relay equipment type RAAAK for single-phase and three-phase auto-reclosing of high voltage circuit-breakers GENERAL The relay equipment for single-phase and three-phase auto­
    OCR Scan PDF
    zelio relay
    Plug-in relays Zelio Relay Catalogue January 06 Contents Zelio Relay - plug-in relays 1 Selection guide…page 2 RSB interface relays b Presentation, characteristics… pages 4 and 5
    Original PDF
    transformer differential relay
    ASEA Catalogue RK 62-10 E Edition 4 Januaryl07S File R, Part 1 Transformer differential relay type RADSE RADSE is a static, transform er diffe re n­ tial relay w ith outstanding speed, sensi­ t i v i ty a n tJ secu rity, O nly o ns relay is req u ired to protect the three phases o f a
    OCR Scan PDF
    asea
    Al lili **IPIP ASEA B R O W N BOVERI ABB Relays Over- or under-frequency relay assem blies ( T r r \ ^ I r r y Abstract Application • Wide setting ranges, 50 Hz relay: 44.41 -50 .7 3 Hz or 44.41-59.15 Hz 60 Hz relay: 53.07-60.62 Hz or 53.07-70.68 Hz • Settings in steps w ith the resolution,
    OCR Scan PDF
    Compact current relay and protection assemblies
    Compact current relay and protection assemblies RXHL 401 and RAHL 401 1MRK 509 062-BEN Page 1 Issued: February 2000 Status: New Data subject to change without notice Features Three phase compact current relay for: • Phase overcurrent protection, three stages
    Original PDF
    rxmda
    H H a sea in f o r m a t io n RFR 1159 E Thermally delayed auxiliary relay type RXMDA Reg. >633 RELAY DESCRIPTION This is a preliminary description based on information to be included in Catalogue RK 21-11 E. • Time-lag on pick up 4-5 Seconds • 2-6 contacts
    OCR Scan PDF
    mk50h28
    MK50H28 ® MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol
    Original PDF
    mk50h28
    MK50H28 MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol
    Original PDF
    mk50h28
    MK50H28 ® MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol
    Original PDF
    reverse power relay
    ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current
    OCR Scan PDF
    049-ben
    Compact current relay and protection assemblies RXHL 411 and RAHL 411 1MRK 509 049-BEN Page 1 Issued: January 2000 Status: New Data subject to change without notice Features Three phase compact current relay for: • Phase overcurrent protection, three stages
    Original PDF
    mk50h28
    MK50H28  MULTI LOGICAL LINK FRAME RELAY CONTROLLER SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent Mode (no LMI Protocol
    Original PDF
    distance relay
    A 3 E A RF 615 026 Distance relay type RAZOG using healthy phase voltages or memory voltage for directional measurement__________ General The standard design of distance relay type RAZOG uses the voltage of the faulted phase/s for directional measurement.
    OCR Scan PDF
    rxmm 1
    J& l i I I #*IPIP A SE A B R O W N BOVERI Type RXMM 1 Dual auxiliary relay, 4 or 6 contacts B03-1212E Page 1 Ju n e 30, 1982 Data subject to ch a n g e without noticc ABB Relays Abstract • Self-reset • D C voltage operated • 2 relay units per module
    OCR Scan PDF
    mk50h28
    MK50H28 MULTI LOGICAL LINK FRAME RELAY CONTROLLER ADVANCE DATA SECTION 1 - FEATURES Based on ITU Q.933 Annex A and T1.617 Annex D Standards for Frame Relay Service and Additional Pocedures for Permanent Virtual Circuits(PVCs). Optional Transparent (or no LMI/LIV Protocol
    Original PDF
    overcurrent relay
    Thermal overcurrent relay and protection assemblies RXVK 2H and RAVK 1MRK 509 003-BEN Page 1 Issued January 2004 Revision: A Data subject to change without notice (SE970118) (SE970139) Features • Thermal overcurrent relay with the same time constants for heating and cooling.
    Original PDF