    Series 1711-000 ■■ Fast and accurate measurement
    Series 1711-000 ■■ Fast and accurate measurement of Redox ■■ Robust epoxy body for high durability ■■ Screw fit for easy installation ■■ Sealed gel reference for low maintenance ■■ Detachable cable fitting for easy cable attachment Epoxy Bodied Industrial
    Original PDF
    1443 Series Silver Half-Cell Redox Electrode
    1443 Series Silver Half-Cell Redox Electrode Specification DataFile ■■ Ideal for use for Redox measurements or accurate halide determinations ■■ Grooved cap for safe grip ■■ Half-cell design allows use of separate reference electrode to suit applications
    Original PDF
    ap300
    Data Sheet SS/AP300 Combination pH/Redox (ORP) Sensors Issue 4 AP300 Series „ Long life – large PTFE junction provides resistance to fouling – double junction with gelled electrolyte provides better-defined junction potentials, creating an inherently-stable reference junction that is resistant
    Original PDF
    ax430
    Data Sheet SS/AX4CO4 Issue 9 Single and Dual Input Analyzers for High-level Conductivity AX430, AX433, AX413 and AX436 Cost effective – select one or two Conductivity inputs or combine pH/Redox (ORP) with Conductivity in one analyzer – integral PID controller (AX430)
    Original PDF
    1440 Series Silver Combination Redox Electrode
    1440 Series Silver Combination Redox Electrode Specification DataFile ■■ Ideal for use for Redox measurements or halide determinations ■■ Robust reference junction ■■ Grooved cap for safe grip ■■ Easily refillable r lo y Ta t- en K Dimensions:
    Original PDF
    1441 Series Platinum Combination Redox Electrode
    1441 Series Platinum Combination Redox Electrode Specification DataFile ■■ Ideal for use for Redox measurements ■■ Robust reference junction ■■ Grooved cap for safe grip ■■ Easily refillable r lo y Ta t- en K Dimensions: Reference Electrolyte:
    Original PDF
    ap200 series
    Data Sheet SS/AP200 Issue 8 Rugged pH/Redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes AP200 Series „ Safe operation and high process resistance – PPS Ryton™ body operates to 6 bar (90 psi) and 130 °C (266 °F) „ Empowers just-in-time maintenance
    Original PDF
    ph meter
    Data Sheet SS/2410_4 Hand–Held pH Meter/Simulator 2410  A ‘two for the price of one’ instrument  Simulates pH and Redox signals for instrument testing  Battery operated for portability  Long battery life  Compact, pocket-sized, rugged case
    Original PDF
    ax488
    Data Sheet SS/AX4DO Issue 9 Single and Dual Input Analyzers for Dissolved Oxygen AX480, AX488 and AX468 Cost effective – select one or two dissolved oxygen inputs or combine pH/Redox (ORP) and dissolved oxygen in one analyzer Reduced installation cost – easy access terminations; reduced panel
    Original PDF
    ap100 series
    Data Sheet SS/AP100 Issue 9 pH/Redox (ORP) Cartridge Sensors with Water-Wash Option AP100 Series Compact 'all-in-one' cartridge design – simplifies sensor replacement, minimizing downtime Detachable cable option – ensures rapid and easy installation and
    Original PDF
    ax410
    Data Sheet SS/AX4CO Issue 12 Single and Dual Input Analyzers for Low-level Conductivity AX410, AX411, AX416, AX450 and AX455 Cost effective – select one or two conductivity inputs or combine conductivity and pH/Redox (ORP) in one analyzer – integral PID controller (AX410)
    Original PDF
    redox
    1442 Series Platinum Combination Semi-micro Redox Electrode Specification DataFile ■■ Ideal for use for Redox measurements in small samples ■■ Robust reference junction ■■ Grooved cap for safe grip ■■ Easily refillable Dimensions: Reference
    Original PDF
    redox
    Data Sheet SS/AX4PH Issue 9 Single and Dual Input Analyzers for pH/Redox (ORP) AX460, AX466 and AX416 Cost effective – select one or two pH/Redox (ORP) inputs or combine pH/Redox (ORP) and conductivity in one analyzer Reduced installation cost – easy access terminations; reduced panel space
    Original PDF
    pH/Redox (ORP) Analyzers Data Sheet SS/4630_12
    pH/Redox (ORP) Analyzers Data Sheet SS/4630_12 Models 4630 & 4635 (incorporating Water Wash Versions 4631 & 4636) ■ Comprehensive range of field-proven electrode systems and electrodes – satisfies broad range of applications ■ Comprehensive diagnostics facility with in-built
    Original PDF
    ax416
    User Guide IM/AX4PH Issue 12 Single and Dual Input Analyzers for pH/Redox (ORP) AX416, AX436, AX460, AX466 & AX468 ABB The Company EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental
    Original PDF
    redox
    Data Sheet SS/2867_3 pH and Redox (ORP) Industrial Dip Electrode Systems 2867 Series ■ Simple, robust design in three dip lengths ■ Positive salt-bridge flow from integral reservoir ■ Easily-replaced, reliable combination electrode ■ Built-in sight glass for salt-bridge reservoir
    Original PDF
    tbx5
    Data Sheet SS/TBX5_3 pH/Redox (ORP) Sensors for Process Monitoring TB(X)5 Series  Next Step™ Solid State reference – eliminates poisoning, pumping and plugging  Advantage™ Series with solution ground rod – permits continuous sensor diagnostics
    Original PDF
    Operating Instructions pH/Redox (ORP) Analyzers
    Operating Instructions pH/Redox (ORP) Analyzers IM/4600–PH_12 Models 4630 & 4635 (incorporating Water Wash Versions 4631 & 4636) ABB The Company EN ISO 9001:2000 EN 29001 (ISO 9001) GI E D Cert. No. Q 05907 As a part of ABB, a world leader in process automation technology, we offer customers
    Original PDF
    xa03
    www.crouzet.com "Application-specific" analogue extensions XA03 Part number 88970800 XA04W: Mix of inputs in the same casing: Pt 100, pH, ORP (Redox), Current (4 - 20 mA) XA03: 3 Pt 100 temperature inputs in the same casing "Application-specific" examples:
    Original PDF
    pH-electrodes, redox electrodes and accessories
    pH-electrodes, redox electrodes and accessories GE 014 GE 100 GE 101 GE 103 GE 105 GE 106 GE 108 GE 109 GE 117 Redoxelectrode pH-electrode pH-electrode Low cost pH-electrode Standard pH-electrode Injection pH-electrode Double chamber pH-electrode (incl. KN03 1M)
    Original PDF
    product information features ● purpose designed
    product information features ● purpose designed for water quality monitoring ChemiloxAQUA7 TM water quality monitor ● robust, compact unit ● zero calibration ● minimal maintenance requirements ● integrated sensors for key parameters: ● integral reference electrode
    Original PDF
    ■ Building management ■ Advertising hoardings ■
    ■ Building management ■ Advertising hoardings ■ Pump management www.millenium3.crouzet.com Logic for all! 3rd generation of logic controllers at the core of your industry Actual size ■ More memory for your applications ■ More comfort largest display on the market