PULSE TRANSFORMER IN TRIGGER Search Results
PULSE TRANSFORMER IN TRIGGER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TPD4206F | Toshiba Electronic Devices & Storage Corporation | Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=500 V / Iout=2.5 A / SSOP30 | Datasheet | ||
| TPD4204F | Toshiba Electronic Devices & Storage Corporation | Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=2.5 A / SSOP30 | Datasheet | ||
| TPD4165K | Toshiba Electronic Devices & Storage Corporation | Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=3 A / HDIP30 | Datasheet | ||
| TPD4207F | Toshiba Electronic Devices & Storage Corporation | Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=5 A / SSOP30 | Datasheet | ||
| TPD4163K | Toshiba Electronic Devices & Storage Corporation | Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=1 A / HDIP30 | Datasheet |
Documents mentioning PULSE TRANSFORMER IN TRIGGER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| scr trigger pulse transformer | SCR TRIGGER PULSE TRANSFORMER Turns Ratio 1:1:1 PARAMETER @25oC MIN. TYP. MAX. UNITS Inductance 200 µH Leakage Inductance 1.5 µH DCR Each Winding 47.7 mΩ Interwinding Capacitance 8.5 Pf Hipot 2000 VRMS PHYSICAL DIMENSIONS All dimensions in inches (mm): |
Original | ||||
| sbaa096 | Application Report SBAA096 – June 2003 Interfacing the ADS1202 Modulator With a Pulse Transformer in Galvanically Isolated Systems Miroslav Oljaca, Tom Hendrick Data Acquisition Products ABSTRACT The ADS1202 is a precision, 80dB dynamic range, delta-sigma (∆Σ) modulator operating |
Original | ||||
| triac | APPLICATION NOTE TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction |
Original | ||||
| triac triggering | APPLICATION NOTE TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction |
Original | ||||
| an436 | AN436 APPLICATION NOTE TRIAC CONTROL BY PULSE TRANSFORMER INTRODUCTION Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction of the commutation capability of the triac. |
Original | ||||
| trigger transformer | Imaging D A T A S H E E T Lighting Telecom Trigger Transformers and Chokes Trigger Transformers and Chokes Description Features PerkinElmer has been manufacturing high voltage transformers since 1956. • Peak output voltage up to 40kV Standard and custom designs |
Original | ||||
| AUIRB24427S Features • Product Summary Very low | AUIRB24427S Features • Product Summary Very low output resistance Extended supply voltage range: 12.5V to 24V TTL/CMOS compatible inputs CMOS Schmitt-triggered inputs Matched propagation delay for both channels Outputs in phase with inputs |
Original | ||||
| afm-11 | UNIVERSAL PHASE ANGLE AFM-11 TRIGGER MODULE X10221 INTRODUCTION This single phase or phase to phase trigger module uses variable phase angle control with adjustable signal matching, selectable soft start and integral current limit input. The pulse train output is reliable, |
Original | ||||
| trigger module | UNIVERSAL PHASE ANGLE TRIGGER MODULE AFM-11 X10221 INTRODUCTION This single phase or phase to phase trigger module uses variable phase angle control with adjustable signal matching, integral current limit input and adjustable soft start. The pulse train output is reliable, powerful and universally applicable to |
Original | ||||
| triac control | National Semiconductor COP Note 6 February 1981 Table of Contents 1 0 Triac Control 1 0 TRIAC CONTROL 1 1 Basic Triac Operation 1 2 Triggering 1 3 Zero Voltage Detection 1 4 Direct Couple 1 5 Pulse Transformer Interface 1 6 False Turn-on 2 0 SOFTWARE TECHNIQUES |
Original | ||||
| AUIRB24427S Features Product Summary Very low | AUIRB24427S Features Product Summary Very low output resistance Extended supply voltage range: 12.5V to 24V TTL/CMOS compatible inputs CMOS Schmitt-triggered inputs Matched propagation delay for both channels Outputs in phase with inputs |
Original | ||||
| ap4340 | Application Note 1078 Application Notes for AP4340/L System Solution Prepared by Su Qing Hua System Engineering Dept. transformer to the primary side, and provided as a triggering primary switch turn on signal for the main controller. By fast response to secondary side voltage, the |
Original | ||||
| TYPE 11Z TRIGATE PULSE TRANSFORMERS DESIGNED FOR | TYPE 11Z TRIGATE PULSE TRANSFORMERS DESIGNED FOR LOW CO ST SCR TRIGGERING APPLICATIONS FEATURES • Designed for low cost SC R triggering applications including motor speed controls, heater controls, and incandescent lighting controls. • Designed with flexible leads. |
OCR Scan | ||||
| FAN6210 Primary-Side Synchronous Rectifier (SR) | FAN6210 Primary-Side Synchronous Rectifier (SR) Trigger Controller for Dual Forward Converter Features Description Primary-Side Trigger Controller for Dual Forward Converters with Synchronous Rectifier (SR) Specialized SR Controller for Dual Forward |
Original | ||||
|
|
||||||
| FAN6210 Primary-Side Synchronous Rectifier (SR) | FAN6210 Primary-Side Synchronous Rectifier (SR) Trigger Controller for Dual Forward Converter Features Description Primary-Side Trigger Controller for Dual Forward Converters with Synchronous Rectifier (SR) FAN6210 is a primary-side trigger Integrated Circuit (IC) |
Original | ||||
| sidac | SECTION 4 THE SIDAC, A NEW HIGH VOLTAGE BILATERAL TRIGGER Edited and Updated packages. Breakdown voltages ranging from 104 to 280 V are available. The MKP3V devices feature bigger chips and provide much greater surge capability along with somewhat higher RMS current ratings. |
Original | ||||
| trigger transformer | Custom Products Vishay Dale Magnetic Components Switch Mode Magnetics CUSTOM DESIGN AND PRODUCTION Vishay Dale has extensive facilities for custom design and production of custom magnetics. Design applications include: • PWM, PSM and FM Transformers • Pulse and Trigger Transformers |
Original | ||||
| triggered spark gap | Mini-Triggered Spark Gaps & Transformers Key Features • High reliability Extremely low jitter Environmentally durable Small size Matching trigger transformers Applications • Excelitas’ Mini-Triggered Spark Gaps are designed for high reliabilty switching up to 4 kV |
Original | ||||
| galvanic | Maxim > App Notes > Protection and isolation Sensor signal conditioners Signal generation circuits Keywords: pulse-width modulation, PWM, 4-20mA transmitter, galvanic isolation, Schmitt-trigger buffer Aug 05, 2010 APPLICATION NOTE 4483 PWM-controlled 4–20mA transmitter is galvanically isolated |
Original | ||||
| ® APPLICATION NOTE AN ISOLATED GATE DRIVE FOR | ® APPLICATION NOTE AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs by J.M. Bourgeois ABSTRACT 1. INTRODUCTION Power MOSFET and IGBT gate drives often face isolation and high voltage constraints. The gate drive described in this paper uses a Printed Circuit Board based transformer |
Original | ||||
| APPLICATION NOTE AN ISOLATED GATE DRIVE FOR | APPLICATION NOTE AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs by J.M. Bourgeois ABSTRACT 1. INTRODUCTION Power MOSFET and IGBT gate drives often face isolation and high voltage constraints. The gate drive described in this paper uses a Printed Circuit Board based transformer |
Original | ||||
| triggered spark gap | P erkinElmer’s Mini-Triggered Mini-Triggered Spark Gaps and Transformers EVERYTHING IN A Spark Gaps are designed for high relia- NEW bility switching up to 4 kV and 10 kA. LIGHT. Constructed of hermetically sealed ceramic-metal, filled with pressurized gas, they are typically used for activating |
Original | ||||
| TRANSFORMER APPLICATIONS Contents impedance | TRANSFORMER APPLICATIONS Contents impedance matching transformers… 2 selection procedure for matching transformers… 2 selection strategy… 3 transformers for thyristor drives |
Original | ||||