Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PULSE TRANSFORMER APPLICATION NOTE Search Results

    PULSE TRANSFORMER APPLICATION NOTE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TPD4206F
    Toshiba Electronic Devices & Storage Corporation Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=500 V / Iout=2.5 A / SSOP30 Datasheet
    TPD4204F
    Toshiba Electronic Devices & Storage Corporation Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=2.5 A / SSOP30 Datasheet
    TPD4165K
    Toshiba Electronic Devices & Storage Corporation Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=3 A / HDIP30 Datasheet
    TPD4207F
    Toshiba Electronic Devices & Storage Corporation Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=5 A / SSOP30 Datasheet
    TPD4163K
    Toshiba Electronic Devices & Storage Corporation Intelligent power device (High voltage PWM DC brushless motor driver) / VBB=600 V / Iout=1 A / HDIP30 Datasheet

    Documents mentioning PULSE TRANSFORMER APPLICATION NOTE

    Document Partial File Text Tags Type PDF
    miniature
    HIGH FREQUENCY MAGNETICS Application Note for Miniature Pulse Transformer TM9919A 2795N Transformer Application Note The 2795N transformer provides two transformation ratios to match both 120Ω and 75Ω line impedances with Lucent 5 V transceivers. The ratio of the two transformer impedance ratios is within 0.07% of the ratio of the two
    Original PDF
    triac triggering
    APPLICATION NOTE  TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction
    Original PDF
    triac
    APPLICATION NOTE  TRIAC CONTROL BY PULSE TRANSFORMER Ph. RABIER Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction
    Original PDF
    an436
    AN436 APPLICATION NOTE TRIAC CONTROL BY PULSE TRANSFORMER INTRODUCTION Among the many ways to drive a triac the pulse transformer is one of the easiest. By applying some simple rules it can be used to design an efficient triac triggering circuit without reduction of the commutation capability of the triac.
    Original PDF
    tm9921
    HIGH FREQUENCY MAGNETICS T3/DS3/E3/STS-1 Miniature Transformer TM9921 • Supports application rates for DS3 (44.736 Mbps) SONET STS-1 (51.84 Mbps) and E3 (34.368 Mbps) • Miniature surface-mount pulse transformer that operates at pulse repetition rates between 30 Mbps and 60 Mbps
    Original PDF
    ncp160
    Document 616 Toroidal Transformer – Q3903-AL • Specified by ON Semiconductor for use with their NCP1605 PFC Controller. Referenced as X25, pulse transformer on evaluation board NCP1605FORWGEVB and Application Note AND8292. • Recommended by Texas Instruments for use with their
    Original PDF
    Document 616 Toroidal Transformer – Q3903-AL •
    Document 616 Toroidal Transformer – Q3903-AL • Specified by ON Semiconductor for use with their NCP1605 PFC Controller. Referenced as X25, pulse transformer on evaluation board NCP1605FORWGEVB and Application Note AND8292. • Recommended by Texas Instruments for use with their
    Original PDF
    toroidal transformer
    Document 616 Toroidal Transformer – Q3903-AL • Specified by ON Semiconductor for use with their NCP1605 PFC Controller. Referenced as X25, pulse transformer on evaluation board NCP1605FORWGEVB and Application Note AND8292. • Recommended by Texas Instruments for use with their
    Original PDF
    q3903-al
    Document 616 Toroidal Transformer – Q3903-AL • Specified by ON Semiconductor for use with their NCP1605 PFC Controller. Referenced as X25, pulse transformer on evaluation board NCP1605FORWGEVB and Application Note AND8292. • Recommended by Texas Instruments for use with their UC3875
    Original PDF
    coev magnetics
    Maxim > App Notes > TELECOM Keywords: transformers, turns ratio, inductance, primary winding, secondary winding, isolation voltage, Pulse Engineering, Halo Electronics, Bel Fuse, Coev Magnetics, Tyco Aug 10, 2001 APPLICATION NOTE 351 T1/E1 and T3/E3 Transformer Selection Guide
    Original PDF
    an993
    AN993 APPLICATION NOTE ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by I. Dal Santo, U. Moriconi The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    an993
    AN993 APPLICATION NOTE ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by F. Sandrini & U. Moriconi The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    an993
    AN993 APPLICATION NOTE ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by I. Dal Santo, U. Moriconi The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    an993
    AN993 APPLICATION NOTE ® ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by I. Dal Santo, U. Moriconi The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    hv400
    No. AN9301 Application Note April 1994 HIGH CURRENT LOGIC LEVEL MOSFET DRIVER Author: John Prentice Introduction Although the HV400 was designed as an interface between a pulse transformer and a power MOSFET, there are applications for high current MOSFET gate drive controlled
    Original PDF
    base pulse transformer
    QUAD PORT 10/100 BASE PULSE TRANSFORMER P/N: XF-LCZ3W4CA Page : 1/3 Feature  Molding process. IEEE 802.3 Ethernet compatible. 100 base-TX surface mountable. Design for multi-port repeater and Ethernet switching HUB application. Customer designs available for specific application.
    Original PDF
    an993
    AN993 APPLICATION NOTE  ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by F. Sandrini, U. Moriconi and I. Dal Santo The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    slua253
    Application Note SLUA253 - January 2001 Accurate PWM Duty Cycle Clamp Michael O’Loughlin System Power ABSTRACT Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty
    Original PDF
    an993
    AN993 APPLICATION NOTE ® ELECTRONIC BALLAST WITH PFC USING L6574 AND L6561 by F. Sandrini, U. Moriconi and I. Dal Santo The advent of dedicate IC for lamp ballast applications is replacing the old solutions based on bipolar transistor driven by a saturable pulse transformer.
    Original PDF
    sbaa096
    Application Report SBAA096 – June 2003 Interfacing the ADS1202 Modulator With a Pulse Transformer in Galvanically Isolated Systems Miroslav Oljaca, Tom Hendrick Data Acquisition Products ABSTRACT The ADS1202 is a precision, 80dB dynamic range, delta-sigma (∆Σ) modulator operating
    Original PDF
    ca1523
    The Ca1523 Variable Interval Pulse Regulator (VIPUR) For Switch Mode Power Supplies Application Note April 1994 AN8614.1 Systems that require line-isolated power supply voltages may be powered with the CA1523 regulator in a transformer flyback-converter system like the one shown in Figure 2(a).
    Original PDF
    National Semiconductor Application Note 1755
    National Semiconductor Application Note 1755 Steve Schulte January 15, 2008 Introduction (LO) modulating power switches with independent pulse width timing. The main difference between the topologies are, the Half Bridge topology employs a transformer to provide input / output ground isolation and a step down or step up
    Original PDF
    National Semiconductor Application Note 2043 Ajay
    National Semiconductor Application Note 2043 Ajay Hari March 18, 2010 Introduction (LO) modulating power switches with independent pulse width timing. The main difference between the topologies are, the Half Bridge topology employs a transformer to provide input / output ground isolation and a step down or step up
    Original PDF
    an993
    AN993 Application note Electronic ballast with PFC using L6574 and L6561 Introduction Dedicated ICs for lamp ballast applications are now replacing the old solutions based on bipolar transistors driven by a saturable pulse transformer. The L6574 is a high-performance ballast driver, designed using 600-V BCD offline
    Original PDF