Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PT100 SENSOR INTERFACE WI Search Results

    PT100 SENSOR INTERFACE WI Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-VHDCIMX200-000.5
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-000.5 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male .5m PDF
    CS-VHDCIMX200-002
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-002 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 2m PDF
    CS-VHDCIMX200-003
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-003 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 3m PDF
    CS-VHDCIMX200-008
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-008 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 8m PDF
    CS-VHDCIMX200-005
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-005 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 5m PDF

    Documents mentioning PT100 SENSOR INTERFACE WI

    Document Partial File Text Tags Type PDF
    pt100 sensors
    G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data
    Original PDF
    FlexTemp 2301 Temperature Transmitter 4…20 mA
    FlexTemp 2301 Temperature Transmitter 4…20 mA transmitter for Pt100 sensors 2-, 3- or 4-wire sensors Accuracy better than 0.25°C Sensor offset correction Automatic/configurable cable resistance compensation (2-wire) Sensor error detection 2-way configuration (Windows)
    Original PDF
    PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER
    PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3.75 kVAC galvanic isolation 4…20 mA loop output 1- and 2-channel versions ATEX Ex version DIN rail mounting Application: Electronic temperature measurement with resistance
    Original PDF
    SITRANS T measuring instruments for temperature
    SITRANS T measuring instruments for temperature Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ Overview • Temperature-linear characteristic can be selected for all temperature sensors • Automatic correction of zero and span
    Original PDF
    th300
    2 © Siemens AG 2013 Temperature Measurement 2/2 Product overview 2/124 2/7 2/11 2/18 2/25 2/31 2/38 2/45 2/57 2/62 2/70 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system
    Original PDF
    2 © Siemens AG 2015 Temperature Measurement 2/2
    2 © Siemens AG 2015 Temperature Measurement 2/2 2/7 2/11 2/18 2/25 2/31 2/38 2/45 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART
    Original PDF
    sem1610
    UNIVERSAL DIN RAIL TRANSMITTER SEM1610 SIMPLE CONFIGURATION VIA USB PORT UNIVERSAL PT100, THERMOCOUPLE, mV, mA Input ISOLATED INPUT PUSH BUTTON USER TRIM (4 to 20) mA TWO WIRE OUTPUT 10 YEAR WARRANTY INTRODUCTION The SEM1610 is the new generation DIN rail mounted temperature transmitter from Status Instruments. It has been designed to
    Original PDF
    050-1aa00-0be4
    Product information for LOGO! Manual 6ED1 050-1AA00-0BE4, Release 07/2001 In this product information…you will find supplementary information on analog LOGO! Expansion module AM2 PT100 (order no. 6ED1 055-1MD00-0BA0). Please refer to the LOGO! Manual for information not found in this product information.
    Original PDF
    Signal Isolating Converters, Trip Amplifiers and
    Signal Isolating Converters, Trip Amplifiers and Displays Catalogue 2012/2013 Analogue Signal Conditioning The World of Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal
    Original PDF
    kt98
    Advant Controller 31 Intelligent Decentralized Automation System Basic Unit 07 KT 98 KT98_02.EPS Hardware 2.2 Basic Unit 07 KT 98 Basic unit with max. 1 MB user program + 1 MB user data + 256 kB RETAIN, CS31 system bus KT98_02.EPS The basic unit 07 KT 98 is offered with several networking possibilities: 07 KT 98 R0120 with Profibus interface, 07 KT 98
    Original PDF
    PRetrans 5114 PROGRAMMABLE TRANSMITTER Input for
    PRetrans 5114 PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3-port 3.75 kVAC galvanic isolation Current and voltage output Universal voltage supply 1- and 2-channel versions Loop supply > 18 V in Ex zone 0 Application: Electronic temperature measurement with resistance sensor
    Original PDF
    mtw 12
    Intelligent interface modules Temperature modules for PT 100 Sensors MTW 12,4 MTW 12,4 2- 3-wire 4-wire Circuit diagram Input E1 PT 100 Output ϑ U ϑ E2 Technical data Supply voltage range Supply current Cable resistance (without PT100) Output signals Tolerance
    Original PDF
    Solar inverters ABB monitoring and communications
    Solar inverters ABB monitoring and communications PVI-AEC-EVO PVI-AEC-EVO is the low cost solution for remote monitoring of PV plants with all ABB devices. The modular and expandable architecture combined with the din-rail mounting system makes the PVI-AECEVO suitable for any kind of installation
    Original PDF
    R300 Series Temperature Sensor DESCRIPTION Other
    R300 Series Temperature Sensor DESCRIPTION Other potential applications for this harsh duty sensor may The R300 Series is a passive, resistive temperature device include fluid or air temperature sensing within the engine (RTD), high temperature probe. This product features a robust,
    Original PDF
    kt97hw01
    Advant Controller 31 Intelligent Decentralized Automation System Basic Units 07 KT 97, 07 KT 96, 07 KT 95 KT97HW01.EPS Hardware 2.1 Basic Unit 07 KT 97 R0100 Basic unit with max. 480 kB user program + 256 kB user data, CS31 system bus KT97HW01.EPS The basic unit 07 KT 97 R100 is the standard device for all applications. In addition, there are basic units with reduced
    Original PDF
    pt1000 rtd
    Temperature Data Loggers with 1 or 2 External Inputs OMYL-T11 and OMYL-T12 OMYL-T11 OMYL-T12 Both models shown actual size. U Integral Temperature Sensor U Plus One (OMYL-T11) or Two (OMYL-T12) External Inputs for Temperature (Pt100/Pt1000 RTD/Thermistor)
    Original PDF
    102-2012:QuarkCatalogTempNew 8/14/12 7:31 AM Page
    102-2012:QuarkCatalogTempNew 8/14/12 7:31 AM Page 102 Oscilloscopes Accessories USB DrDAQ® Data Logger PicoLog CM3 Current Data Logger POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 1 PP706 Whether you are a teacher, student, hobbyist or professional, the USB DrDAQ® Data Logger gives you an inexpensive entry
    Original PDF
    07 kt 98
    Advant Controller 31 Intelligent Decentralized Automation System Basic Unit 07 KT 98 KT98_02.EPS Hardware 2.2 Basic Unit 07 KT 98 Basic unit with max. 1 MB user program + 1 MB user data + 256 kB RETAIN, CS31 system bus KT98_02.EPS The basic unit 07 KT 98 is offered with several networking possibilities. A table on page 2.2-3 shows the features of the
    Original PDF
    Peltier-Controller • Output for Peltiermodules •
    Peltier-Controller • Output for Peltiermodules • pt100 / pt1000 or customized sensors, user programmable • 2-or 3 wire connection • PID-Controller, programmable • Supply voltage, optional with switch on or switch off function • Signal output, optional with alarm- or temperature
    Original PDF
    ANALOGUE TEMPERATURE CONTROLLERS SPECIFICATION
    ANALOGUE TEMPERATURE CONTROLLERS SPECIFICATION TOS ON/OFF & PROPORTIONAL CONTROLLER Supply voltage: Power drain: Scale accuracy: Scale range: Input sensor: Max ext. resist: Control band: The TOS range of temperature controllers offer an extremely cost effective analogue
    Original PDF
    kt97hw01
    Advant Controller 31 Intelligent Decentralized Automation System Basic Units 07 KT 97, 07 KT 96, 07 KT 95 KT97HW01.EPS Hardware 2.1 Basic Unit 07 KT 97 Basic unit with max. 480 kB user program + 256 kB user data, CS31 system bus KT97HW01.EPS The basic unit 07 KT 97 R200 is the standard device for all applications. In addition, there are basic units with reduced
    Original PDF
    tf02
    FieldIT Data Sheet 10/11-8.25 EN Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 (RTD), thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit
    Original PDF