PT100 LR Search Results
Documents mentioning PT100 LR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| capteur pt100 | BattTemp, Thermomètre Pt100 Thermomètre alimenté par batterie Affichage frontal programmable Entrée pour capteur Pt100 Gamme de mesure -200…850°C Température ambiante -10…70°C Précision 0,3°C Durée de vie de la batterie approx. 3 ans IP65 - Humidité relative 98% |
Original | ||||
| q414 | ACTIONI/Q® Q414 & Q415 MODEL Protecting the Integrity of Industrial Process Signals RTD Input, Three-Wire Transmitter Provides Two DC Outputs in Proportion toTwo Pt100Ω RTD Temperature Inputs Benefits n Multi-Channel Design Provides Two (2) Threewire Transmitters in 1 |
Original | ||||
| pt100 | CombiTemp TFRH TM Hygienic – RTD temperature sensor Main features Pt100 sensor element, 2- or 4-wire Built in graphical display, CombiViewTM DFON optional Head mounted 4…20 mA transmitter, FlexTop type 22xx HART®, PA ATEX |
Original | ||||
| CombiTemp TFRN TM Industrie – RTD | CombiTemp TFRN TM Industrie – RTD Temperatursensor Haupteigenschaften Sensor in Pt100-Ausführung, ATEX Programmierbar über 2- oder 4-polig HART®, PA Eingebautes Grafikdisplay, CombiViewTM DFON optional erhältlich Messkopf Verstärker mit |
Original | ||||
| capteur pt100 | CombiTemp TFRN TM Capteur de température RTD industriel Principaux avantages Capteur Pt100, 2 ou 4 fils HART®, PA Affichage graphique intégré, ATEX Programmable par écran CombiViewTM DFON en option Transmetteur 4…20 mA monté |
Original | ||||
| CombiTemp TFRN TM Industrial – RTD temperature | CombiTemp TFRN TM Industrial – RTD temperature sensor Main features Pt100 sensor element, ATEX Programmable by touch screen Easy and full programmable 2- or 4-wire HART®, PA Built in graphical display, CombiViewTM DFON optional |
Original | ||||
| METRA 28C Calibrator, Multimeter and | METRA 28C Calibrator, Multimeter and Milliohmmeter • Universal calibrator, simulator and multimeter mA / mV ¼ V / °C (Pt100/1000, Ni100/1000, type J, L, T, U, K, E, S, R, B and N thermocouples) / 30 ¼ 2000 W • Dual mode – simultaneous simulation and measurement (U/I) |
Original | ||||
| Intrinsic Safety Isolation Barriers SIB 1000 | Intrinsic Safety Isolation Barriers SIB 1000 Series 380 $ Basic Unit C A B A B ߜ Input Output Isolation ߜ For J, K, T, E, R, S, B Thermocouples, mV, and Pt100 and Ni100 RTDs ߜ Converts Signal from Hazardous Location into 4 to 20 mA Signal ߜ Field Programmable |
Original | ||||
| 6ed1055-1md00-0ba1 | 6ED1055-1MD00-0BA1 Page 1 Product data sheet 6ED1055-1MD00-0BA1 LOGO! AM2 RTD EXPAN. MODULE, PU: DC 12/24V, 2AI, -50… +200 DEGR/C PT100/1000 Supply voltages Rated value 12 V DC Yes 24 V DC Yes ; 10,8… 28.8 V DC Analog inputs Number of analog inputs 2 ; 2 or 3 wire connection |
Original | ||||
| ACTIONI/Q® Q510 Multi-Channel RTD Input | ACTIONI/Q® Q510 Multi-Channel RTD Input Two-WireTransmitter Provides 2 or 4 Current Loop Outputs in Proportion to the PT100Ω RTD Inputs Description Benefits Up to 4 Two-Wire Transmitters in a Single Package High Density DIN Rail Mounting The Q510 is a DIN rail mount, RTD Input, dual or quad channel two-wire transmitter. Each channel |
Original | ||||
| CombiTemp TFR5 TM Room or outdoor temperature | CombiTemp TFR5 TM Room or outdoor temperature sensor Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores |
Original | ||||
| Signal Isolating Converters, Trip Amplifiers and | Signal Isolating Converters, Trip Amplifiers and Displays Catalogue 2012/2013 Analogue Signal Conditioning The World of Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal |
Original | ||||
| 32423 | Fieldbus Independent I/O Modules Analog Input Modules for RTD's 750-461, (/xxx-xxx) Manual Version 1.1.2 ii • General Copyright © 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden |
Original | ||||
| g418-0001 | ULTRA SLIMPAK® G418-0001 RTD Input Field Configurable Isolator Provides an Isolated, Linearized DC Output in Proportion to an RTD Input Description Benefits The Ultra SlimPak G418 is a DIN rail mount, RTD input signal conditioner with 1800VDC isolation between input, output and power. The field configurable input and output offers flexible, wide |
Original | ||||
|
|
||||||
| PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER | PRetrans 5131 2-WIRE PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3.75 kVAC galvanic isolation 4…20 mA loop output 1- and 2-channel versions ATEX Ex version DIN rail mounting Application: Electronic temperature measurement with resistance |
Original | ||||
| q116 | ACTIONI/Q® Q116 RTD Input Limit Alarm Provides Relay Contact Closures at a Preset RTD Input Level Description Benefits The ActionI/Q model Q116 is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint |
Original | ||||
| PRetrans 5114 PROGRAMMABLE TRANSMITTER Input for | PRetrans 5114 PROGRAMMABLE TRANSMITTER Input for RTD, TC, mV, linear resistance, mA, and V 3-port 3.75 kVAC galvanic isolation Current and voltage output Universal voltage supply 1- and 2-channel versions Loop supply > 18 V in Ex zone 0 Application: Electronic temperature measurement with resistance sensor |
Original | ||||
| Capteurs pour les process industriels Vue | Capteurs pour les process industriels Vue d’ensemble – Edition 2013 Partenariat. Précision. Innovation. Capteurs pour les Process Industriels MEX5, MEM5 MIX7, MIM7 MEP5 MEX8 MMN5 MPx6 ge Pa MEX2 MEX3, MEM3 Pression mécanique M MMX1 an M omè an tr o e |
Original | ||||