PT100 2 W Search Results
PT100 2 W Price and Stock
Samtec Inc
Samtec Inc UMPT-10-01.5-L-V-S-W-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-01.5-L-V-S-W-TR | 3,168 |
|
Buy Now | |||||||
Samtec Inc UMPT-10-02.5-L-V-S-W-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-02.5-L-V-S-W-TR | 1,351 |
|
Buy Now | |||||||
Samtec Inc UMPT-10-01-L-RA-WT-M-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-01-L-RA-WT-M-TR | 909 |
|
Buy Now | |||||||
Samtec Inc UMPT-10-01.5-G-V-S-W-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-01.5-G-V-S-W-TR | 575 |
|
Buy Now | |||||||
Samtec Inc UMPT-10-02.5-L-V-S-W-M-TRPower to the Board 2.00 mm mPOWER Ultra Micro Power Terminal |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
UMPT-10-02.5-L-V-S-W-M-TR | 552 |
|
Buy Now | |||||||
Documents mentioning PT100 2 W
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| signal converter pt100 | Signal converter PT100 / RTD - signal isolator/converter PT100, 2-/3-Conductor disconnector converter PT100 Output select • 2-way isolation between input/output and power supply • PT100 2-/ 3-conductor • Output can be switched calibrated via DIP-switch |
Original | ||||
| pt100 sensors | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I |
Original | ||||
| mcr-sl-pt100-ui | MINI MCR-SL-PT100-UI… Configurable Temperature Transducer for PT100 Data Sheet 11/2004 Product Description Features MINI MCR-SL-PT100-UI… is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection of PT100 resistance thermometers in acc. with IEC 60751 in 2, 3 and 4-conductor |
Original | ||||
| signal conditioning | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473010000 MCZ PT100/3 CLP 0…200C |
Original | ||||
| pt100 | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473000000 MCZ PT100/3 CLP -50C…+150C |
Original | ||||
| signal isolator | Product catalogue | Electronics | Analogue signal conditioning | Temperature RTD - signal isolator/converter | PT100, 2-/3-/4-conductor temperature transducer | MCZ PT100/3 CLP General ordering data Order No. Part designation Version EAN Qty. 8473020000 MCZ PT100/3 CLP 0…300C |
Original | ||||
| mcr-sl-pt100-lp-i | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| pt100 sensors | G2TI1 PT100 Temperature measurement with PT100 sensors (2- and 3-wire connection) Sensor failure detection Reinforced insulation of the input circuit Measured value transmitting via standard bus Modular monitoring system Width 22.5mm Industrial design Technical data |
Original | ||||
| pt100 sensor | Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the |
Original | ||||
| FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde | FR NOTICE D’INSTRUCTIONS - AT42 thermomètre sonde platine Pt100 Entrée sonde platine Pt100 Résolution 1 °C ou 0,1 °C Affichage 10000 points 2 seuils d'alarme Valeur moyenne Sortie analogique ajustable 4-20 mA (0-20 mA) ou 0-10 V L’ indicateur AT42 est un thermomètre numérique dédicacé aux entrées sondes platines Pt100 équipé de 2 |
Original | ||||
| 1xpt100 | Kabelfühler j^electrotherm t ^p K5 Ausgabe 06/93 Ausführung -als Widerstandsthermometer 1 x Pt100 Kl. A oder B DIN EN 60751 2 x Pt100 Kl. A oder B DIN EN 60751 nach Auftrag in 2- oder 3-Leiter-Schaltung (1xPt100 auch in 4-Leiter-Schaltung) -als Thermoelement |
OCR Scan | ||||
| 4082 | External Wiring PT100 PT100 Shielding cable *1 CH1 L+ LIFG 1mA R Error status CR#30: Error status (see the table below): AG *2 *3 System grounding Earth (100 or less) ╳ H’4082 Register for storing all error status. See the table of error status for more information. |
Original | ||||
| 45tcr | Type: 45TCR PT100 Temperature Control Relay q q q q q q q 2 or 3 wire PT100 input Monitoring or control of temperature -50°C to 300°C (5 ranges) Adjustable set point and hysteresis Relay Operation Inversion switch - Normal/Inverted Analogue output (0 - 10V DC) relative to set point or measured temperature |
Original | ||||
|
|
||||||
| 45tcr | Type: 45TCR PT100 Temperature Control Relay q q q q q q q 2 or 3 wire PT100 input Monitoring or control of temperature -50°°C to 300°°C (5 ranges) Adjustable set point and hysteresis Relay Operation Inversion switch - Normal/Inverted Analogue output (0 - 10V DC) relative to set point or measured temperature |
Original | ||||
| tx-m12-rtd | DATENBLATT TX-M12-RTD TX-M12-RTD U Universell für alle Pt100/500/1000 Applikationen U USB programmierbarer Ausgang 4-20 mA oder 0-10 V U IP68 Edelstahl-Gehäuse mit kompakten Abmessungen U Für Pt100, Pt500, Pt1000, 2- oder 3-Draht U Temperaturbereich -200…+850°C |
Original | ||||
| pt100 thermistor | DTM 910 LCD Type Pt100 Temperature Indicator The DTM 910 will give an accurate direct temperature reading in either °C or °F from a 2, 3 or 4 wire Pt100 thermistor*. Simple single step calibration is achieved using a 20-turn potentiometer which allows sensitive adjustment. The meter is housed in a robust carrier which can be bolted in place or panel |
Original | ||||
| DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 | DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 18 4 5 6 7 8 9 Output 2 (W/Z types) Output 4 (Z types) 10 11 12 13 14 15 Output 3 (Z types) 16 17 7 18 - 2 4 3 6 Supply 7 8 9 7 - Digital I/P 5 PT100 1 Output 1 8 9 + T/C 8 9 10V O/P V/A PRG mute PT100 12-24Vac/dc +/- 10% 110/230V with transformers |
Original | ||||
| pt100 | DIGITAL TEMPERATURE & PROCESS CONTROLLERS + 16 17 18 4 5 6 7 8 9 Output 2 (W/Z types) Output 4 (Z types) 10 11 12 13 14 15 Output 3 (Z types) 16 17 7 18 - 2 4 3 6 Supply 7 8 9 7 - Digital I/P 5 PT100 1 Output 1 8 9 + T/C 8 9 10V O/P V/A PRG mute PT100 12-24Vac/dc +/- 10% 110/230V with transformers |
Original | ||||