Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PROPORTIONAL 20MA CURRENT LOOP Search Results

    PROPORTIONAL 20MA CURRENT LOOP Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-QSFPLOOPBK-003
    Amphenol Cables on Demand Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] PDF
    SF-QSFPLOOPBK-002
    Amphenol Cables on Demand Amphenol SF-QSFPLOOPBK-002 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 0W Power Consumption [Copper+Optical Ready] PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFPPLOOPBK-003.5
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation PDF
    SF-QSFPLOOPBK-001
    Amphenol Cables on Demand Amphenol SF-QSFPLOOPBK-001 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] PDF

    Documents mentioning PROPORTIONAL 20MA CURRENT LOOP

    Document Partial File Text Tags Type PDF
    Model SCC and SCV Open Loop Hall Effect The SCC
    Model SCC and SCV Open Loop Hall Effect The SCC Series provides either a 4-20mA or 0-20mA unipolar output proportional to DC current. The SCV Series provides either a 0-5V or 0-10V unipolar output proportional to DC current. The SCC and SCV clamp around existing wiring for easy installation.
    Original PDF
    Model SCC and SCV Open Loop Hall Effect The SCC
    Model SCC and SCV Open Loop Hall Effect The SCC Series provides either a 4-20mA or 0-20mA unipolar output proportional to DC current. The SCV Series provides either a 0-5V or 0-10V unipolar output proportional to DC current. The SCC and SCV clamp around existing wiring for easy installation.
    Original PDF
    apt-35l
    AlphaPOWER Range AC Current Input 2 Wire Transmitter APT-35L Function: The APT-35L will convert a selected AC Signal into a proportional, linear and highly accurate 4 to 20mA current output signal. An internal transformer isolates the input from the output enabling the transmitter to withstand large momentary
    Original PDF
    1771-pd
    Product Data Proportional/Integral/Derivative Control (2ĆLoop) Module AllenĆBradley Proportional/Integral/Derivative Control (2ĆLoop) Module (Cat. No. 1771-PD) Product Data General Description The Proportional/Integral/Derivative Control (2-Loop) Module Assembly
    Original PDF
    dms-an-20
    Application Note www.murata-ps.com 4-20mA Current Loop Primer DMS-AN-20 Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA
    Original PDF
    ® DMS APPLICATION NOTE 4-20mA Current Loop Primer
    ® DMS APPLICATION NOTE 4-20mA Current Loop Primer Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA current loops are used;
    Original PDF
    www.PAControl.com DMS APPLICATION NOTE INNOVATION
    www.PAControl.com DMS APPLICATION NOTE INNOVATION and EXCELLENCE "2 0 4·20mA Current Loop Primer Introduction This application note's primary goal is to provide an easy·to· understand primer for users who are not familiar with 4·20mA current-loops and their applications. Some of the many topics
    Original PDF
    szza045
    Application Report SZZA045 - January 2004 Implementing a 4-mA to 20-mA Current Loop on TI DSPs Steve Sams and Jim Lyday Signal Processing Solutions/Semiconductor Group ABSTRACT Use of 4-mA to 20-mA (4−20 mA) current loops has become the standard in the process-control industry due to their increased resistance to noise compared to
    Original PDF
    Maxim > App Notes > Amplifier and Comparator
    Maxim > App Notes > Amplifier and Comparator Circuits Keywords: op amp, high-voltage op amp, operational amplifier, high voltage operational amplifier, VI converter, current-loop system, 4-20mA Feb 16, 2010 APPLICATION NOTE 4394 How to Use High-Voltage and High-Current-Drive Op Amps in 4–
    Original PDF
    E6C 1/16 DIN Temperature & Process Controller
    E6C 1/16 DIN Temperature & Process Controller Single loop temperature / process controller 1/16 DIN (48 x 48mm) Profiler function – 2 programs x 16 segment 70mm depth behind panel Universal Input & 2 or 3 Outputs The markets for industrial and scientific equipment demand that controllers not only provide a
    Original PDF
    Maxim > App Notes > TEMPERATURE SENSORS and
    Maxim > App Notes > TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: analog, temperature sensors, temperature, 4-20mA, temp sensor, loop powered Feb 03, 2003 APPLICATION NOTE 1873 4mA–20mA Loop Powered Temperature Sensor Abstract: A simple circuit that allows a 4mA–20mA to power an analog temperature sensor.
    Original PDF
    Fuji Electric’s PX Series fuzzy logic controllers
    Fuji Electric’s PX Series fuzzy logic controllers are the leaders in precision control. Breakthrough technology PX redesigned from the inside out B REAKTHROUGH TECHNOLOGY. That’s what the Fuji PX series fuzzy logic controllers are all about. Faster. Smarter. Tougher. More Versatile. More Features.
    Original PDF
    ® DMS APPLICATION NOTE 4-20mA Current Loop
    ® DMS APPLICATION NOTE 4-20mA Current Loop Configurations and FAQ’s Introduction Since loop-powered process monitors must function accurately with currents between 4 and 20mA, low-power liquid crystal displays (LCD’s), similar to the type found in inexpensive hand-held calculators,
    Original PDF
    nte974
    NTE974 Integrated Circuit Phase–Frequency Detector Description: The NTE974 consists of two digital phase detectors, a charge pump, and an amplifier. In combination with a voltage controlled multivibrator, it is useful in a broad range of phase–locked loop applications.
    Original PDF
    4-20ma
    ® DMS APPLICATION NOTE 4-20mA Current Loop Configurations and FAQ’s Introduction Since loop-powered process monitors must function accurately with currents between 4 and 20mA, low-power liquid crystal displays (LCD’s), similar to the type found in inexpensive hand-held calculators,
    Original PDF
    Multi-Loop Digital Temperature Controller MA901 R
    Multi-Loop Digital Temperature Controller MA901 R R MA901 General Description The MA901 controls up to 8 channels in a compact 1/4 DIN size. The MA901 increases zone density and makes smaller numbers of loops affordable, yet still holds many of the advantages that a single loop controller might offer. This unit will aid designers of control equipment saving
    Original PDF
    Z SERIES FUZZY CONTROLLER X (48)96, 96)96mm)
    Z SERIES FUZZY CONTROLLER X (48)96, 96)96mm) PYX5,9 DATA SHEET The PYX is a state-the-art temperature controller offering enhanced control through the use of fuzzy logic. By employing fuzzy logic the PYX virtually eliminates system overshoot and effectively supresses fluctuation of the
    Original PDF
    2b57
    Low Cost, Two-Wire Temperature Transmitter A N A LO G D E V IC E S □ MODEL 2B57 FEATURES Low Cost Compatible with Standard 4-20m A Loops Low Span Drift: ±0.0Q5%/°C max Low Nonlinearity: :f0.05% max R F I Immunity Small Size: 1.5" X 1.5" X 0.4” A P P L IC A T IO N S
    OCR Scan PDF
    q500
    ACTIONI/Q® Q500 Loop-Powered, Multi-Channel Isolator Provides up to 4 Isolated DC Current Outputs in Proportion to the Input Currents Description Benefits Up to 4 Loop Isolators in a Single Package Prevents Ground Loops SnapLoc™ Plug-in Terminals The Q500 is a DIN rail mount, loop-powered isolator with single, dual or quad (4) channel capability.
    Original PDF
    q501
    ACTIONI/Q® Q501 Multi-Channel, DC Input, Isolating 2-Wire Transmitter Provides One or Two Isolated 4-20mA Output Current Loops in Proportion to One or Two DC Inputs Description Benefits Multi-Channel Design Prevents Ground Loops High Density DIN Rail Mounting
    Original PDF
    fuzzy controller
    Z SERIES FUZZY CONTROLLER X (48)48mm) PYX4 DATA SHEET The PYX is a state-the-art temperature controller offering enhanced control through the use of fuzzy logic. By employing fuzzy logic the PYX virtually eliminates system overshoot and effectively supresses fluctuation of the
    Original PDF