Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PRECISION INSTRUMENT TRANSFORMER Search Results

    PRECISION INSTRUMENT TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    INA125TDA1
    Texas Instruments Instrumentation Amplifier with Precision Voltage Reference 0- Visit Texas Instruments
    INA125TDA2
    Texas Instruments Instrumentation Amplifier with Precision Voltage Reference 0- Visit Texas Instruments
    INA118UBG4
    Texas Instruments Precision, Low Power Instrumentation Amplifier 8-SOIC Visit Texas Instruments Buy
    INA115AU/1K
    Texas Instruments Precision Instrumentation Amplifier 16-SOIC Visit Texas Instruments Buy
    INA118PB
    Texas Instruments Precision, Low Power Instrumentation Amplifier 8-PDIP Visit Texas Instruments Buy

    Documents mentioning PRECISION INSTRUMENT TRANSFORMER

    Document Partial File Text Tags Type PDF
    2120b
    + PRECISION BK INSTRUCTION MANUAL ® MODELS 2120B and 2125A 30 MHz DUAL-TRACE OSCILLOSCOPES BK PRECISION + ® TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must often be performed where exposed high voltage is present. An electrical shock causing
    Original PDF
    2700 Series Instrument Specifications Copyright ©
    2700 Series Instrument Specifications Copyright © 2003–2013 Audio Precision, Inc. All rights reserved. part number 8215.0001 rev 000 No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying,
    Original PDF
    uc3854
    DN-39E Design Note OPTIMIZING PERFORMANCE IN UC3854 POWER FACTOR CORRECTION APPLICATIONS by Bill Andreycak The performance of the UC3854 Power Factor Correction IC in the 250 watt application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999
    Original PDF
    dn-39
    DN-39E Design Note OPTIMIZING PERFORMANCE IN UC3854 POWER FACTOR CORRECTION APPLICATIONS by Bill Andreycak The performance of the UC3854 Power Factor Correction IC in the 250 watt application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999
    Original PDF
    I INSTRUCTION MANUAL xrm^/n BK PRECISION MODEL
    I INSTRUCTION MANUAL xrm^/n BK PRECISION MODEL 3011B 2 MHz DIGITAL DISPLAY FUNCTION GENERATOR B K FrtEdSiC N TEST INSTRUMENT SAFETY WARNING N orm al use o f test equipm ent exposes you to a certain amount o f dan ger from electrical shock because testing must often b e
    OCR Scan PDF
    metrahit
    METRA 28S and 29S Precision Digital Multimeter, Power Meter METRAHit â28S and 29S • 300,000 digits and triple display • Precision multimeter (V, dB, A, Ω, F, Hz, F, °C/°F) • Current measurement with (clip-on) current transformer: a transformation ratio of 1000:1 or 10000:1
    Original PDF
    LIMITED ONE YEAR WARRANTY MAXTEC INTERNATIONAL
    LIMITED ONE YEAR WARRANTY MAXTEC INTERNATIONAL CORPORATION warrants to the original purchaser that its BKPrecision product, and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from the date of purchase.
    OCR Scan PDF
    4011a
    INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MODEL 4011A MODELO 4011A 5 MHz FUNCTION GENERATOR with DIGITAL DISPLAY 5MHz GENERADOR DE FUNCIONES CON DIGITOS INDICADOR 1 TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be
    Original PDF
    INSTRUCTION MANUAL SPECTRUM ANALYZERS MODELS
    INSTRUCTION MANUAL SPECTRUM ANALYZERS MODELS 2165A 2620A 2625 2630 TEST INSTRUMENT SAFETY Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed voltage is present. An electrical shock causing 10 milliamps of
    Original PDF
    4017a
    INSTRUCTION MANUAL MODEL 4017A MANUAL DE INSTRUCCIONES MODELO 4017A 10 MHz SWEEP FUNCTION GENERATOR with DIGITAL DISPLAY 10MHz GENERADOR DE BARRIDO/FUNCIONES CON EXHIBICION DIGITAL TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be
    Original PDF
    METRA 30M Precision Digital Multimeter •
    METRA 30M Precision Digital Multimeter • Precision multimeter (V, mA, Ω, Hz, °C/°F) and data logger • 1,200,000 digit display range High resolution for: DC/AC+DC voltage: 100 nV/1 µV DC and AC+DC Current: 100 pA • TRMS AC+DC • Milliohmmeter with 2 and 4-wire connection
    Original PDF
    pi-100
    PI-100 Series Precision Instrumentation Balun Network Analyzer NETWORK CABLE OR CONNECTOR UNDER TEST Typical Use Diagram Features/Advantages • 50 ohm SMA input • 100 ohm output as two 50 ohm SMA or SMB • Shielded metal enclosure • Made in USA • 100% tested
    Original PDF
    4285a
    Agilent 4284A/4285A Precision LCR Meter Family 20 Hz to 1 MHz 75 kHz to 30 MHz Technical Overview A new standard for precise component, semiconductor and material measurements Agilent precision LCR meter family Utilize state-of-the art measurement technologies
    Original PDF
    Instruction Manual for Model 1715A 0-60V, 0-2A DC
    Instruction Manual for Model 1715A 0-60V, 0-2A DC POWER SUPPLY With Dual LED Display TABLE OF CONTENTS Page Page TEST INSTRUMENT S A F E T Y… inside front cover APPLICATIONS… 19
    OCR Scan PDF
    ldc501
    www.thinkSRS.com Laser Diode Controller LDC501  Laser diode controller with integrated temperature controller LDC501 Laser Diode Controller Laser Diode Controller · 500 mA low-noise current source · Low drift (<10 ppm/°C) · 1.1 MHz modulation · CC & CP mode dynamic switching
    Original PDF
    305-rtd
    Made in the USA 305-RTD Miniature Panel Thermometer 11434ML-02A This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.
    Original PDF
    2015 MASTER CATALOGUE MEDICAL © HEINE Optotechnik
    2015 MASTER CATALOGUE MEDICAL © HEINE Optotechnik GmbH & Co. KG. Printed in Germany, 10.2014 All information, specifications and illustrations contained in this catalogue are based on the latest product information available at the time of publication. Errors and
    Original PDF
    tca-bnc
    TekConnect™ Adapters TCA75 • TCA-BNC • TCA-SMA • TCA-N Data Sheet TCA-SMA - TekConnect-to-SMA DC to ≥18 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-N - TekConnect-to-N DC to ≥11 GHz (Instrument Dependent) 50 Ω Input (Only) Applications
    Original PDF
    voltage transformer
    g GEA-13361 Indoor/Outdoor Voltage Transformer Model JVA-0C, 10 kV BIL, 600 V Application Designed for indoor and outdoor service; suitable for operating meters, instruments, relays and control devices. Thermal Rating (Volt-Amperes) 55 °C Rise above 30 °C Ambient
    Original PDF