Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    POTENTIOSTAT Search Results

    POTENTIOSTAT Result Highlights (3)

    Part ECAD Model Manufacturer Description Download Buy
    LMP91000SD/NOPB
    Texas Instruments Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy
    LMP91000SDE/NOPB
    Texas Instruments Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy
    LMP91000SDX/NOPB
    Texas Instruments Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications 14-WSON -40 to 85 Visit Texas Instruments Buy

    Documents mentioning POTENTIOSTAT

    Document Partial File Text Tags Type PDF
    lmp9100
    LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
    Original PDF
    LMP91000 Sensor AFE System: Configurable AFE
    LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
    Original PDF
    lmp9100
    LMP91000 www.ti.com SNAS506G – JANUARY 2011 – REVISED FEBRUARY 2012 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C
    Original PDF
    LMP91002 www.ti.com SNIS163A – APRIL 2012 –
    LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End
    Original PDF
    lmp9100
    LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
    Original PDF
    LMP91000 www.ti.com SNAS506H – JANUARY 2011 –
    LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C
    Original PDF
    LMP91000 www.ti.com SNAS506H – JANUARY 2011 –
    LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES 1 • 23 • Typical Values, TA = 25°C
    Original PDF
    LMP91000 Sensor AFE System: Configurable AFE
    LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
    Original PDF
    LMP91002 www.ti.com SNIS163A – APRIL 2012 –
    LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End
    Original PDF
    potentiostat
    LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91002 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output
    Original PDF
    lmp91002
    LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91002 is a programmable Analog Front End (AFE) for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output
    Original PDF
    lmp91002
    LMP91002 www.ti.com SNIS163 – APRIL 2012 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End
    Original PDF
    lmp9100
    LMP91002 www.ti.com SNIS163A – APRIL 2012 – REVISED MARCH 2013 LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91002 FEATURES DESCRIPTION • The LMP91002 is a programmable Analog Front End
    Original PDF
    lmp9100
    LMP91000 www.ti.com SNAS506H – JANUARY 2011 – REVISED MARCH 2013 LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications Check for Samples: LMP91000 FEATURES DESCRIPTION • The LMP91000 is a programmable Analog Front End
    Original PDF
    Ajinder Singh TI Designs Gas Sensor Platform
    Ajinder Singh TI Designs Gas Sensor Platform Reference Design TI Designs Design Features TI Designs are analog solutions created by TI’s analog experts. Reference Designs offer the theory, part selection, simulation, complete PCB schematic & layout, bill of materials, and measured performance of
    Original PDF
    tsu102
    TSU101, TSU102, TSU104 Nanopower, rail-to-rail input and output, 5 V CMOS operational amplifiers Datasheet - production data • Application performances guaranteed over industrial temperature range • Fast desaturation 6& 768 627 768 Applications
    Original PDF
    max1408
    19-2229; Rev 0; 10/01 Low-Power, 16-Bit Multichannel DAS with Internal Reference,10-Bit DACs, and RTC The MAX1407/MAX1408/MAX1414 are available in space-saving 28-pin SSOP packages, while the MAX1409 is available in a 20-pin SSOP package. Applications Medical Instruments
    Original PDF
    19-3120; Rev 0; 1/04 +1.8V to +5.5V,
    19-3120; Rev 0; 1/04 +1.8V to +5.5V, Ultra-Low-Power, 8-Bit, Voltage-Output DACs The MAX5510/MAX5511 are single, 8-bit, ultra-lowpower, voltage-output, digital-to-analog converters (DACs) offering Rail-to-Rail® buffered voltage outputs. The DACs operate from a 1.8V to 5.5V supply and consume less than 6µA, making them desirable for lowpower and low-voltage applications. A shutdown mode
    Original PDF
    microsens
    Microsens Amperometric Sensor MAES-2402, Chlorine (HOCl) Sensor General description Operating principle The integrated chlorine sensor MAES-2402 measures the concentration of Hypochlorous Acid (HOCl) in water using the principle of conventional amperometric technique.
    Original PDF
    max5522
    19-3064; Rev 1; 12/04 Dual, Ultra-Low-Power, 10-Bit, Voltage-Output DACs Features The MAX5522–MAX5525 are dual, 10-bit, ultra-lowpower, voltage-output, digital-to-analog converters (DACs) offering rail-to-rail buffered voltage outputs. The DACs operate from a 1.8V to 5.5V supply and consume
    Original PDF
    an-1798
    ANALOG edge 電気化学センサを用いた設計 Application Note AN-1798 Muna Acosta, Applications Engineer すでに1950年には、電気化学センサは酸素(ガス) の監視に使用されるようになっていました。しかし ながら、近年の人体の安全性への関心の高まりにつ
    Original PDF
    max4036
    19-3142; Rev 2; 11/04 Low IBIAS, +1.4V/800nA, Rail-to-Rail Op Amps with +1.2V Buffered Reference The single MAX4036/MAX4037 and dual MAX4038/ MAX4039 operational amplifiers operate from a single +1.4V to +3.6V (without reference) or +1.8V to +3.6V (with reference) supply and consume only 800nA of supply
    Original PDF