Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PNOZPOWER Search Results

    SF Impression Pixel

    PNOZPOWER Price and Stock

    Pilz International

    Pilz International PNOZPOWER BUS-TERMINATOR

    TERMINATION PLUG PNOZPOWER
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS PNOZPOWER BUS-TERMINATOR Bulk 4 Weeks 1
    • 1 $45.28
    • 10 $43.01
    • 100 $36.22
    • 1000 $36.22
    • 10000 $36.22
    Get Quote

    Documents mentioning PNOZPOWER

    Document Partial File Text Tags Type PDF
    pnozpower
    PNOZpower Expander Module PNOZ po3.2p Technical Details Electrical Data Supply Voltage Power Consumption Total Current Utilisation category to EN 60947-4-1 EN 60947-5-1 (DC13: 6 cycles/min.) Output Contacts Contact fuse protection according to EN 60947-5-1
    Original PDF
    pnozpower
    PNOZpower Expander Module PNOZ po3.1p Technical Details Electrical Data Supply Voltage Power Consumption Total Current Utilisation category to EN 60947-4-1 EN 60947-5-1 (DC13: 6 cycles/min.) Output Contacts Contact fuse protection according to EN 60947-5-1
    Original PDF
    s11-s12
    PNOZpower Base unit PNOZ p1vp Technical details PNOZ p1vp Application range In accordance with EN 954-1, EN ISO 13849-1 up to Category 4; E-STOP, safety gate Electrical data Supply voltage Tolerance Power consumption Voltage and current at S11-S12, S11-S52, S21-S22
    Original PDF
    pnoz
    PNOZpower Expander Module PNOZ po3.3p Technical Details Electrical Data Supply Voltage Power Consumption Total Current Utilisation category to EN 60947-4-1 Expander module for the PNOZpower modular safety system in accordance with EN 60204-1 (VDE 0113-1) and
    Original PDF
    pnoz
    PNOZpower Control Module PNOZ pe1p Technical Details Electrical Data Supply voltage Tolerance Residual Ripple Power consumption Voltage and current at the input circuit at the feedback circuit Times Switch-on delay Control module for the PNOZpower modular safety system in accordance
    Original PDF
    pnozpower
    PNOZpower Base Unit PNOZ p1p Technical Details Electrical Data Supply voltage Tolerance Power consumption Voltage and current at the input, reset and feedback circuits Semiconductor Outputs External Supply Voltage Min. input resistance in the starting torque
    Original PDF
    pnozpower
    PNOZpower Power Supply PNOZ pps1p Technical Details PNOZ pps1p Electrical Data Supply Voltag Output Voltage Tolerance Output Current Power Consumption Max. Supply Interruption before De-energisation Mechanical Data Cable cross section 1 Core 2 cables with the same cross
    Original PDF
    pnozpower
    PNOZpower Expander Module PNOZ po3p Technical Details Electrical Data Supply Voltage Power Consumption Utilisation category to EN 60947-4-1 EN 60947-5-1 (DC13: 6 cycles/min.) Output Contacts Contact fuse protection according to EN 60947-5-1 Expander module for the
    Original PDF
    pnoz
    PNOZpower Bus interface PNOZ pe2p Technical details PNOZ pe2p not shown Bus interface for the PNOZpower modular safety system in accordance with EN 60204-1 (VDE 0113-1), 11/98 and IEC 60204-1, 10/97 Electrical data Supply voltage Tolerance Residual ripple
    Original PDF
    pnozpower
    PNOZpower Expander Module PNOZ po4p Technical Details Electrical Data Supply Voltage Power Consumption Utilisation category to EN 60947-4-1 EN 60947-5-1 (DC13: 6 cycles/min.) Output Contacts Contact fuse protection according to EN 60947-5-1 Times Switch-on delay
    Original PDF
    pilz
    IE NZ Pilz GmbH & Co. KG Sichere Automation Felix-Wankel-Straße 2 73760 Ostfildern Germany Telephone: +49 711 3409-0 Telefax: +49 711 3409-133 E-Mail: pilz.gmbh@pilz.de Pilz Ireland Industrial Automation Cork Business and Technology Park Model Farm Road
    Original PDF
    Compact safety relays PNOZsigma Monitoring of E-STOP, safety gates, light curtains, light barriers and two-hand control Safe timer relay application Maximum functionality in minimum width. Business activities Pilz – Products and services … Sensor technology
    Original PDF
    pnozs
    Blocs logiques de sécurité compacts PNOZsigma Surveillance d’arrêts d’urgence, de protecteurs mobiles, de barrières immatérielles et de commandes bimanuelles Utilisation comme relais temporisés de sécurité Fonctionnalité maximale dans un encombrement minimal.
    Original PDF