Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PHOTOMETRY Search Results

    Documents mentioning PHOTOMETRY

    Document Partial File Text Tags Type PDF
    7326
    7326 MULTIPLIER PHOTOTUBE 1 .68" D i a . Curv ed C i r c u la r Se m itran sp are nt Photocathode 10-Stage, TENTATIVE RCA-7326 phototube as is a head-on intended flying-spot for type use scanning in the In photometry, low d a r k as high entire its fast and
    OCR Scan PDF
    PHOTODIODE Si photodiode S1336 series UV to near
    PHOTODIODE Si photodiode S1336 series UV to near IR for precision photometry Features Applications ● High sensitivity ● Low capacitance ● High reliability ● Analytical instruments ● Optical measurement equipment ■ General ratings / Absolute maximum ratings
    Original PDF
    PHOTODIODE Si PIN photodiode S1722-02 Large area,
    PHOTODIODE Si PIN photodiode S1722-02 Large area, high-speed PIN photodiodes for UV to near IR photometry S1722-02 is a high-speed Si PIN photodiode having a large active area of φ4.1 mm. Using quartz glass as the light input window, this photodiode delivers high sensitivity extending to the far UV region and is suitable for optical power meters.
    Original PDF
    Si photodiodes S2386 series For visible to IR,
    Si photodiodes S2386 series For visible to IR, general-purpose photometry Features Applications High sensitivity Analytical instruments Low dark current Optical measurement equipment High reliability Superior linearity General ratings / Absolute maximum ratings
    Original PDF
    c7557-01
    Multichannel detector head controller C7557-01 For control of multichannel detector head and data acquisition The C7557-01 is specifically designed for basic control in multichannel photometry. When connected to a HAMAMATSU multichannel detector head and a personal computer, the C7557-01 allows easy control of the detector head and data acquisition by using dedicated software that
    Original PDF
    l7820
    NEW Calibrated Deuterium Light Source L7820 is a logo mark for an accreditation system based on Japanese Measurement Law. Our Planning & Engineering Division is accredited in accordance with ISO/IEC Guide 25: 1990 in the field of photometry calibration. (Our accreditation number is 0081.)
    Original PDF
    l7810
    NEW Calibrated Xenon Light Source L7810 is a logo mark for an accreditation system based on Japanese Measurement Law. Our Planning & Engineering Division is accredited in accordance with ISO/IEC Guide 25: 1990 in the field of photometry calibration. (Our accreditation number is 0081.)
    Original PDF
    LEDs and Photometry Appnote 1 The observed
    LEDs and Photometry Appnote 1 The observed spectrum of electromagnetic radiations, extends from a few Hz to beyond 1024 Hz, covering some 80 octaves. The narrow channel from 430 THz to 750 THz would be entirely negligible, except that more information is communicated to
    Original PDF
    HAMAMATSU CORP n E Silicon Photodiodes ® Type No.
    HAMAMATSU CORP n E Silicon Photodiodes ® Type No. D ■ ‘JHST b G ' i 0 0 G S S 24 (Visible Light to IR, for Precision Photometry) Photosensitive Surface Spectral Response Out­ line Package (mm) «J Characteristics (25°C) Radian Sensitivity (A/W) Size
    OCR Scan PDF
    PRODUCT DATA SHEET Type Neon Size T-1¼ (4mm)
    PRODUCT DATA SHEET Type Neon Size T-1¼ (4mm) Description T4 Neon Bi-Pin Lamp Part No. 1MHBP-1 Ø 4.0 Max Drawing Not To Scale All Dimensions In mm Ø 4.75 Max 14.0 Max 7.5 Max 5.85 6.85 Ø 0.5 Nom 2.54 Nom PHOTOMETRY DATA Brightness Nominal (orange glow)
    Original PDF
    DETECTOR-FILTER COMBINATION SERIES PLANAR
    DETECTOR-FILTER COMBINATION SERIES PLANAR DIFFUSED SILICON PHOTODIODES APPLICATIONS • Analytical Chemistry • photometry • Densitometers • Photometry/Radiometry • Spectroradiometry • Medical Instrumentation • Liquid Chromatography The Detector-Filter combination series incorporates a filter with a photodiode
    Original PDF
    LEDs and Photometry Appnote 1 by George Smith The
    LEDs and Photometry Appnote 1 by George Smith The observed spectrum of electromagnetic radiations, extends from a few Hz to beyond 1024 Hz, covering some 80 octaves. The narrow channel from 430 THz to 750 THz would be entirely negligible, except that more information is communicated to
    Original PDF
    CENTRQNIC INC» E-0 13E D | DIV m sa so 7- 0 D 0 0
    CENTRQNIC INC» E-0 13E D | DIV m sa so 7- 0 D 0 0 2 C1C1 T | I 1 TECHNICAL DATA SHEET C H A -200 C H A -204 HYBRID PHOTOMETRY AMPLIFIER C entro n ic CHA s e r ie s of p h o to d e te c to rs i s a h y b rid photom etry a m p lifie r w ith a b u i l t - i n GaAsP photodiode MQS FET
    OCR Scan PDF