    float switch
    Pepperl+Fuchs offers a wide range of float switches: Application - suitable for use up to Ex-area zone 1 - mercury-free switching element - nominal voltage, 8 V per EN 60947-5-6 (NAMUR) - connected through a transformer isolated barrier (i.e. KFD2-SR…) - mercury-free switching element
    Original PDF
    kfd2
    Switch Amplifier KFD2-SOT2-Ex2.IO Assembly Features • 2-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR inputs Isolated passive transistor output, non-polarized Line fault detection (LFD) Reversible mode of operation
    Original PDF
    kfd2-sr2-ex2.w
    Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • 2-channel Control circuit EEx ia IIC
    Original PDF
    kfd2-sr2-ex1.w
    Transformer Isolated Barriers KFD2-SR2-Ex1.W Output: Relay Input I EEx ia IIC 3400 Ω ≤ R ≤ 2 kΩ 1+ Switch S3 in position I without SC • 1-channel Control circuit EEx ia IIC Reversible mode of operation 1 relay output with 1 changeover
    Original PDF
    Transformer Isolated Barriers KFD2-SRA-Ex*
    Transformer Isolated Barriers KFD2-SRA-Ex* Output: Relay Input EEx ia IIC Input II + - Control circuit EEx ia IIC 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short circuit LK and interruption LB) with LED indicator (red flashing), switching output and
    Original PDF
    kfd2
    Current limit 35 mA • 1-channel • Output EEx ia IIC • Device installation permissible in zone 2 • 24 V DC nominal supply voltage • Usable up to SIL 3 acc. to IEC 61508 2- 1+ 2- 1+ Standard type KFD2-SL2-Ex1.B Function The KFD2-SD-Ex1.48 and the KFD2-SD-Ex1.48.90A receives its
    Original PDF
    The AS-interface AS-interface replaces the cable
    The AS-interface AS-interface replaces the cable tree PLC / PC PLC / PC 2 wires each for data and power supply AS-i Power supply Only 2 wires total for data and power supply Actuators with integrated AS-i chip Multiple sensor connection Actuators with integrated
    Original PDF
    kfd2-stc4
    KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz (-3 dB) • EMC acc. to NAMUR NE 21
    Original PDF
    kfd2-cd-ex1.32
    KFD2-CD-Ex1.32 Current/voltage repeater Connection • 1-channel Output EEx ia IIC 24 V DC supply voltage Device installation permissible in zone 2 Conversion of current/voltage or voltage/current Elevation/Suppression of the "life
    Original PDF
    kfd2-stc4-ex2
    SMART Transmitter Power Supply KFD2-STC4-Ex2 - Input EEx ia IIC ? - DC 24 V power supply Input ΙΙ EEx ia IIC ? J J 2-wire transmitters - EMC per NAMUR NE 21 - LED per NAMUR NE 44 The SMART transmitter power supplies supply a 2-wire SMART transmitter within a
    Original PDF
    catalog sensors for process applications
    FACTORY AUTOMATION CATALOG SENSORS FOR PROCESS APPLICATIONS 1FQQFSM 'VDIT°6OCFBUBCMFGPSRVBMJUZBOEDIPJDF 8F BSF B MFBEJOH NBOVGBDUVSFS PG JOEVTUSJBM TFOTPST BOE TFOTPS TZTUFNT NBLJOHVTTQFDJBMJTUTJOUIFTFGJFMETUIFSFGPSFQSPWJEJOHZPVXJUIBOFYUFO
    Original PDF
    namur ne 21
    P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W
    Original PDF
    kfd2
    SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1** Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz (-1 dB) EMC acc. to NAMUR NE 21 1+ 3- 1+ + -
    Original PDF
    kfd2
    KFD2-EB.D2A.B Power Rail power feed module for redundant supply, with bus terminals Connection Supply 8+ • 24 V DC supply voltage • Device installation permissible in zone 2 • Supply current ≤ 2 A • Bus access via terminals • Redundant supply • Fault signal output with adjustable
    Original PDF
    Transformer Isolated Barriers Input I EEx ia IIC
    Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21
    Original PDF
    vibration limit switch
    Vibration limit switch Dimensions Ø85 max. 76 L ~25 max. 140 Vibracon LVL-M with plastic housing and process connection Goo 17.5 max. 65 Ø80 max. 60 Vibracon LVL-M NAMUR max. 40.7 max. 173 Vibracon LVL-M with aluminium housing and process connection with flange
    Original PDF
    Dimensions V1 connector PG9 110 Testing magnet
    Dimensions V1 connector PG9 110 Testing magnet LED Housing Housing 41 120 Vibrating Limit Switch LVL 5.5 19 Testing magnet 127 G1A Switching point G1A 25 ø29 L 10 22 LED Switching state (yellow) LVL-N Compact version LVL1 -V1 ooo 10 22 Extended version LVL2
    Original PDF
    namur ne 21
    Transformer Isolated Barrier KF -SR2-Ex1.W Output: Relay - Control circuit EEx ia IIC Class I, Div 1, Groups A-G Switch S3 in position I 1+ - Reversible mode of operation 3- - 1 Signal output with 1 alternator - EMC per NAMUR NE 21 1+ Switch S3 in position I
    Original PDF
    kfu8-ufc-1
    Logic Control Units, Universal Frequency Converters KFU8-UFC-1** 1+ 10 k 3- 1+ 3400 Ω ≤ R ≤ 2 kΩ 1 K-ADP1 RS 232 3- 2 1+ 10 k 3- 1+ 3(+) 2- 3 PC Signal processor TTL yellow/ red green U yellow TXD • 1+ yellow yellow GND • 1-channel
    Original PDF
    kfd2
    P R O C E S S A U T O M A T I O N KFD2-SD-Ex1.48 KFD2-SD-Ex1.48.90A Output EEx ia IIC - Single Channel - Output EEx ia IIC Class I, Div 1, Groups A-G - DC 24 V Loop Powered 2- 1+ 2- 1+ Hazardous area Solenoid Drivers KFD2-SD-Ex1.48 - Output Current KFD2-SD-Ex1.48:
    Original PDF
    kfd2-ut
    P R O C E S S A U T O M A T I O N Converter KFD2-UT-Ex1 Input EEx ia IIC - Single Channel - Input EEx ia IIC Class I, Div 1, Groups A-G cold junction compensation Typ K-CJC Thermocouple - Output: 4… 20mA 2- - Optional 1… 5V Output - Setting options through Serial Interface:
    Original PDF
    limit switch testing
    P R O C E S S   A U T O M A T I O N Vibrating Limit Switch testing magnet 110 - stainless steel housing for rough environmental conditions housing - function test with testing magnet in mounted position housing 41 41 19 G1A G1A 127 Compact version LVL1 LVL1S-G3S-N-V1
    Original PDF
    namur ne 21
    P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21
    Original PDF
    kfd2
    P R O C E S S A U T O M A T I O N - Single Channel Hazardous area TIBs for Current / Voltage KFD2-CD-Ex1.32 Output EEx ia IIC - Output EEx ia IIC Class I, Div 1, Groups A-G ? J - DC 24 V Nominal Power Supply - Voltage / Current or Current / Voltage Conversion
    Original PDF
    Transformer Isolated Barrier KF Input ΙΙ -