PDC13ENG Search Results
PDC13ENG Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: LTC Batteries SL-2790 Size: DD › iXtra – long term high performance Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current Pulse current capability |
Original |
sl-2790pdc13eng | |
|
Contextual Info: › › › › TLM-1550HP High power 4 Volt cell No voltage delay Long shelf life End of life indication capability Performance Data Discharge Capability at +25 °C Typical values for batteries stored at +25 °C for one year 1: 5 A 2: 2 A 3: 15 A, 1 s pulse every 10 s |
Original |
tlm-1550hptlm-1550hp/stlm-1550hp/z2/ttlm-1550hp/z2/pt2+2 | |
|
Contextual Info: LTC Batteries SL-361 Size: 2⁄3AA › Standard use and stand-by Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-361sl-361/ssl-361/tsl-361/p+3 | |
|
Contextual Info: LTC Batteries Size: 2⁄3AA › iXtra – long term high performance Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-761sl-761/tsl-761/s330values+1 | |
|
Contextual Info: › › › › TLP-93111/A High energy Up to 3 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-93111/apdc13eng | |
|
Contextual Info: › › › › TLP-92311/A High energy Up to 1 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-92311/apdc13eng | |
|
Contextual Info: LTC Batteries Size: D › XOL – extended operating life Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-2880sl-2880/tsl-2880/ssl-2880/p+1 | |
SL560Contextual Info: LTC Batteries Size: AA › Extended temperature range Performance Data Typical Discharge Curves at +85 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-560sl-560/tsl-560/ssl-560/p+4 | |
|
Contextual Info: LTC Batteries SL-350 Size: 2AA › Standard use and stand-by Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-350sl-350/ssl-350/tsl-350/p+3 | |
1530AContextual Info: › › › › HLC-1530A Delivering high current pulses Up to 25 years lifetime and more Wide operating temperature range Low self discharge Performance Data Typical values in PulsesPlus TM batteries stored at +25 °C 4.0 System Nominal voltage Nominal capacity |
Original |
hlc-1530ahlc-1530a/shlc-1530a/thlc-1530a/pt2+4 | |
|
Contextual Info: LTC Batteries Size: 1⁄6D › XOL – extended operating life Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-886sl-886/ppdc13eng | |
TLM-1530UHP/T
Abstract: TLM-1520HP/TP
|
Original |
tlm-1520hppdc13engtlm-1530uhp/ttlm-1520hp/tp | |
|
Contextual Info: LTC Batteries SL-360 Size: AA › Standard use and stand-by Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-360sl-360/tsl-360/ssl-360/p+3 | |
|
Contextual Info: LTC Batteries Size: 2AA › XOL – extended operating life Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-850sl-850/ssl-850/tsl-850/p+3 | |
|
|
|||
|
Contextual Info: LTC Batteries Size: AA › XOL – extended operating life Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-860sl-860/ssl-860/tsl-860/p+3 | |
TLP-96311/A/SMContextual Info: › › › › TLP-96311/A High energy Up to 1 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-96311/apdc13engtlp-96311/a/sm | |
|
Contextual Info: › › › › HLC-1550A Delivering high current pulses Up to 25 years lifetime and more Wide operating temperature range Low self discharge Performance Data Typical values in PulsesPlus TM batteries stored at +25 °C 4.0 System Nominal voltage Nominal capacity |
Original |
hlc-1550a20ovehlc-1550/tppdc13eng | |
|
Contextual Info: › › › › TLP-92111/A High energy Up to 3 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-92111/atlp-92111/a/smpdc13eng | |
|
Contextual Info: › › › › TLP-91111/A High energy Up to 3 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-91111/atlp-91111/a/smpdc13eng | |
|
Contextual Info: LTC Batteries Size: 2AA › Extended temperature range Performance Data Typical Discharge Curves at +85 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-550sl-550/ssl-550/tsl-550/p+3 | |
|
Contextual Info: › › › › HLC-1520A Delivering high current pulses Up to 25 years lifetime and more Wide operating temperature range Low self discharge Performance Data Typical values in PulsesPlus TM batteries stored at +25 °C 4.0 System Nominal voltage Nominal capacity |
Original |
hlc-1520apdc13eng | |
|
Contextual Info: LTC Batteries Size: 2⁄3AA › XOL – extended operating life Performance Data Typical Discharge Curves at +25 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-861sl-861/ssl-861/tsl-861/p+3 | |
|
Contextual Info: › › › › TLP-97111/A High energy Up to 3 A pulse capability Instant voltage response No passivation effect Performance Data Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. 1 s pulse to 3 V |
Original |
tlp-97111/apdc13eng | |
|
Contextual Info: LTC Batteries SL-561 Size: 2⁄3AA › Extended temperature range Performance Data Typical Discharge Curves at +85 °C Typical values for batteries stored at +25 °C for one year 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current |
Original |
sl-561sl-561/ssl-561/tsl-561/p+3 | |