PCB THERMAL DESIGN Search Results
PCB THERMAL DESIGN Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022AE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Push-pull type / FLAG signal latch function | Datasheet | ||
| TCTH021AE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Push-pull type | Datasheet | ||
| TCTH012AE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Push-pull type / FLAG signal latch function | Datasheet | ||
| TCTH011AE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Push-pull type | Datasheet | ||
| TCTH011BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=1μA / IDD=1.8μA / Open-drain type | Datasheet |
Documents mentioning PCB THERMAL DESIGN
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Optimizing PCB Thermal Performance for Cree® | Optimizing PCB Thermal Performance for Cree® XLamp® LEDs Table of Contents 1. Introduction… 2 2. Thermal Management Principles… 2 |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L1/L4 | Thermal Overcurrent Circuit Breaker 1410-L1/L4 Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Miniaturised construction minimises PCB real estate required. PCB mounting or integral mounting. Largely temperature-insensitive. |
Original | ||||
| Thermal Design Considerations of Exposed Pad IC | Thermal Design Considerations of Exposed Pad IC As the miniaturization of electronic devices, the small area and close proximity of ICs in these modules demands small packages with excellent thermal properties. Thermal performance is a system level concern, impacted by IC packaging as well as PCB design. |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L/G… | Thermal Overcurrent Circuit Breaker 1410-L/G… Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L/-G… | Thermal Overcurrent Circuit Breaker 1410-L/-G… Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| 1410 | Thermal Overcurrent Circuit Breaker 1410-L/-G… Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L2/G1 | Thermal Overcurrent Circuit Breaker 1410-L2/G1 Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L2/G1 | Thermal Overcurrent Circuit Breaker 1410-L2/G1 Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| Thermal Overcurrent Circuit Breaker 1410-L2/G1 | Thermal Overcurrent Circuit Breaker 1410-L2/G1 Description Single pole press-to-reset thermal circuit breaker with extremely fast overload switching performance (R-type TO CBE to EN 60934). Single hole threadneck, PCB or integral mounting with a choice of designs. |
Original | ||||
| APPLICATION NOTE - ACA0B60 ACA0860 Thermal | APPLICATION NOTE - ACA0B60 ACA0860 Thermal Mounting Supplement RevO Introduction The PCB layout for the ACA0860 family of amplifiers must consider both the electrical requirements of the parts (proper line impedance, bypassing, etc..) and the thermal requirements. The |
OCR Scan | ||||
| APPLICATION NOTE - ACA0860 ACA0860 Thermal | APPLICATION NOTE - ACA0860 ACA0860 Thermal Mounting Supplement Rev 0 Introduction The PCB layout for the ACA0860 family of amplifiers must consider both the electrical requirements of the parts (proper line impedance, bypassing, etc..) and the thermal requirements. The |
OCR Scan | ||||
| Thermal Overcurrent Circuit Breakers | Thermal Overcurrent Circuit Breakers 104/105/106-… Description Miniaturised single pole thermal circuit breaker with push-to-reset, tease- free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for PCB or panel mounting, snap-in or |
Original | ||||
| Thermal Overcurrent Circuit Breakers | Thermal Overcurrent Circuit Breakers 104/105/106-… Description Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for PCB or panel mounting, snap-in or |
Original | ||||
| Thermal Overcurrent Circuit Breaker 104/105/106-… | Thermal Overcurrent Circuit Breaker 104/105/106-… Description Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for PCB or panel mounting, snap-in or |
Original |