PAH450S Search Results
PAH450S Datasheets (4)
TDK-Lambda
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| PAH450S4828 | TDK-Lambda | DC DC Converters, Power Supplies - Board Mount, CONVERT DC/DC 28V OUT 450W 16A | Original | 2 | |||
| PAH450S4828/T | TDK-Lambda | DC DC Converters, Power Supplies - Board Mount, CONVERT DC/DC 28V 16A 450W | Original | 2 | |||
| PAH450S4848 | TDK-Lambda | DC DC Converters, Power Supplies - Board Mount, DC-DC CONVERTER 48VDC 450W 9.4A | Original | 2 | |||
| PAH450S4848/T | TDK-Lambda | DC DC Converters, Power Supplies - Board Mount, CONVERT DC/DC 48V 9.4A 450W | Original | 2 |
PAH450S Price and Stock
TDK Corporation
TDK Corporation PAH450S4848Module DC-DC 48VIN 1-OUT 48V 9.4A 451W 9-Pin Half-Brick |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
PAH450S4848 | 14 | 1 |
|
Buy Now | ||||||
TDK Corporation PAH450S48-28/T- Bulk (Alt: PAH450S48-28/T) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
PAH450S48-28/T | Bulk | 18 Weeks | 1 |
|
Buy Now | |||||
|
PAH450S48-28/T | 840 |
|
Get Quote | |||||||
TDK Corporation PAH450S48-28- Bulk (Alt: PAH450S48-28) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
PAH450S48-28 | Bulk | 18 Weeks | 1 |
|
Buy Now | |||||
TDK Corporation PAH450S48-48Module DC-DC 1-OUT 48V 9.4A 451W 9-Pin Half-Brick - Bulk (Alt: PAH450S48-48) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
PAH450S48-48 | Bulk | 18 Weeks | 1 |
|
Buy Now | |||||
|
PAH450S48-48 | 482 |
|
Get Quote | |||||||
TDK Corporation PAH450S48-48/T- Bulk (Alt: PAH450S48-48/T) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
PAH450S48-48/T | Bulk | 18 Weeks | 1 |
|
Buy Now | |||||
Documents mentioning PAH450S
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pah450s48-series | PAH450S48-SERIES PAH450S48 SERIES Instruction Manual BEFORE USING THE POW ER SUPPLY UNIT B e sure to read this instruction m anual thoroughly before using this product. P ay attention to all cautions and w arnings before using this product. usage could lead to an electrical shock, dam age to the unit or a fire hazard. |
OCR Scan | ||||
| pah450s | Single / Dual Output 50-450W PAH200H PAH450S 2 PAH350S PAH75D PAH300S Y E A R S CC-E CE09XX warranty PAH200S CE10XX PAH150S CE3101 PAH100S ks 医 療 計 測 計 測 その他 F A F A医 療 半導体 その他 PAH75S 半導体 PAE PAH50S ph コンピュータ |
Original | ||||
| pah450s48-28 | DENSEI-LAMBDA PAH450S48 SPECIFICATIONS C247-01-01 25 26 Isolation Resistance Vibration 27 28 29 Shock Weight (Typ.) Size (W x H x D) V A W % A % mV mV mV g mm PAH450S48-28 PAH450S48-48 28 16 448 92 48 9.4 451.2 92 36 - 76 VDC 10.4 10.3 ±1 -40%, +18% 280 56 |
Original | ||||
| PAH450S Series Compact and high-power DC/DC | PAH450S Series Compact and high-power DC/DC Power-module The new era for base station transmission amplifiers: Compact and high-power output PAH450S Series Compact and high-power DC/DC Power-module actual size PAH450S Series High efficiency: 92% - top level in the industry |
Original | ||||
| Lambda for Low Cost of Ownership The choice and | Lambda for Low Cost of Ownership The choice and application of the power supply is an important one. Working with Lambda can help you save time and money, from design concept to years after your system or product is first installed. Why Lambda? Over the last 60 years, Lambda has developed a worldwide |
Original | ||||
| Innovating Reliable Power The choice and | Innovating Reliable Power The choice and application of the power supply is an important one. Working with TDK-Lambda can help you save time and money, from design concept to years after your system or product is first installed. Why TDK-Lambda? Over the last 60 years, TDK-Lambda has developed a |
Original | ||||
| 100c | • 12V output for driving non-isolated converters • Safety Approved • Operation at 100C baseplate • Wide Adjustable Output Range • Industry Standard Half Brick Package Key Market Segments & Applications Base Station Power Amplifiers Bus converters for Distributed Power Architectures |
Original | ||||
| QUICK INDEX NEW IN THIS ISSUE! (Detailed Index - | QUICK INDEX NEW IN THIS ISSUE! (Detailed Index - See Pages 3-24) Digital Signal Processors, iCoupler®, iMEMS® and iSensor™… 805, 2707, 2768-2769 Connectors, Cable Assemblies, IC Sockets… 28-568 RF Connectors… Pages 454-455 |
Original | ||||
| pah350 | DC-DC Converters (Cont.) Fig. 9 — PXF Series 20.3 51.3 28.2 9 8 15.2 7.6 12.7 3 7 6 2.5 BOTTOM 2 1 5 5.1 15.2 10.2 51.3 1 5 2 3 6 7 8 4 9 Fig. 11 — PF Series 4-M3 PAH350, PAH450 Series Pin Function 1 -Vin 2 CASE 3 CNT 4 +Vin 5 -V 6 -S 7 TRM 8 +S 9 +V 57.9 |
Original | ||||
| pah300 | PAH300-450 Series 300W to 450W Half Brick Converters Standard Half Brick Footprint 18-36 or 36-76VDC Inputs 12V 29A - 48V 9.4A Nominal Outputs Through Hole Mounting Low 12.7mm Profile Key Market Segments & Applications Base Station Power Amplifiers |
Original | ||||
| PAH300-450 Series 300W to 450W Half Brick | PAH300-450 Series 300W to 450W Half Brick Converters Features u Standard Half Brick Footprint u 18-36 or 36-76VDC Inputs u 12V 29A - 48V 9.4A Nominal Outputs u Through Hole Mounting u Low 12.7mm Profile u High operating efficiencies (up to 92%) u Constant switching frequency |
Original | ||||
| pah300-450 | PAH300-450 Series 300W to 450W Half Brick Converters Standard Half Brick Footprint 18-36 or 36-76VDC Inputs 12V 29A - 48V 9.4A Nominal Outputs Through Hole Mounting Low 12.7mm Profile Key Market Segments & Applications Base Station Power Amplifiers |
Original | ||||
| QUICK INDEX NEW IN THIS ISSUE! (Detailed Index - | QUICK INDEX NEW IN THIS ISSUE! (Detailed Index - See Pages 3-24) AD9272 Analog Front End, iMEMS® Accelerometers & Gyroscopes… 782, 2583 Connectors, Cable Assemblies, IC Sockets… 28-528 Acceleration and Pressure Sensors… Page 2585 |
Original | ||||
| antenna tower | Switching converter targets base station RF power amplifiers May 3, 2007 4:07 PM When the power converter is in proximity to the PA in an RF transmitter, regardless of whether it is located at the top or the base of the antenna tower, the switching action of the converter is a potential source of RF interference. Many features of |
Original | ||||
|
|
||||||
| • 12V output for driving non-isolated converters | • 12V output for driving non-isolated converters • Safety Approved • Operation at +100°C baseplate • Wide Adjustable Output Range • Industry Standard Half Brick Package Key Market Segments & Applications Base Station Power Amplifiers Bus converters for Distributed Power Architectures |
Original | ||||