OVERLOAD RELAY TYPE PT Search Results
OVERLOAD RELAY TYPE PT Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-059FTYPEMM-025 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-025 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 25 ft | |||
| CO-059FTYPEMM-010 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-010 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 10 ft | |||
| CO-059FTYPEMM-050 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-050 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 50 ft | |||
| CO-059FTYPEMM-003 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-003 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 3 ft | |||
| CO-059FTYPEMM-006 | Amphenol Cables on Demand | Amphenol CO-059FTYPEMM-006 F-Type Coax Cable - RG59 75 Ohm Coaxial Cable - Type F Male / Type F Male (TV/CABLE/SATELLITE) 6 ft |
Documents mentioning OVERLOAD RELAY TYPE PT
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Jnta-No. INFORMATION EX 642-300 E RFR, November | Jnta-No. INFORMATION EX 642-300 E RFR, November 1981 Edition 3 7453 froiW D fiW Fieg, Page 1 Motor Protection Type RAMPA List of contents Section Title Page 1 2 3 4 5 6 GENERAL INPUT CIRCUITRY OVERLOAD RELAY OVERCURRENT RELAY EAH.TH-MULT RELAY NEGATIVE SEQUENCE RELAY |
OCR Scan | ||||
| overload relay | nv6S( Type Z1 MS Thermistor Protection Relay with automatic reset Description Special Features Order Reference The Z1 MS is a thermistor overload relay in accordance with DIN EN 44 081 for PTC-thermistors. It is designed for direct temperature monitoring on motors |
OCR Scan | ||||
| zb150 | Type: ZB150−150 Article No.: 278466 Sales text Overload relay 120−150 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 120…150 Auxiliary contacts N/O = Normally open |
Original | ||||
| zb150 | Type: ZB150−35 Article No.: 278461 Sales text Overload relay 25−35 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 25…35 Auxiliary contacts N/O = Normally open |
Original | ||||
| zb150 | Type: ZB150−125 Article No.: 278465 Sales text Overload relay 95−125 Phase failure sensitivity to IEC/EN 60947, VDE 0660 Part 102 For direct mounting Ordering information Description Overload releases Direct fitting Ir A 95…125 Auxiliary contacts N/O = Normally open |
Original | ||||
| etm22 | Motor thermal protection relay ■ ETM / ETM2 / ETM22 Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2/ETM22 : Fault latching function Pushbutton for local reset Remote reset via external contact |
Original | ||||
| ptc thermistor | Thermistors - PTC PTC Thermistors 39 PTC Electrical characteristics 1 – RESISTANCE - TEMPERATURE CHARACTERISTIC (Log RT – T) A positive Temperature Coefficient (PTC) thermistor is a resistor, mainly composed of solid solutions of baryum and strontium titanates. The addition of dopants makes the component semiconductive and gives it the typical resistance temperature characteristic shown in figure 18. |
Original | ||||
| DC Solid State Relay SH O RT CIRCUIT PR O TECTED | DC Solid State Relay SH O RT CIRCUIT PR O TECTED , O PTICALLY ISOLATED, 2A, 60 VDC '«'TELEDYNE re la y s Part* Number D ESC Drawing Number 90091-008 CD01CFW CD01CFY SSR with Control Status SSR with Short Circuit Protection 90091-004 CD21CDW CD21CDY FEATURES |
OCR Scan | ||||
| User Manual E300 Electronic Overload Relay Bul. | User Manual E300 Electronic Overload Relay Bul. 193/592 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to |
Original | ||||
| e3 plus | E3 and E3 Plus Electronic Overload Relays with Integrated DeviceNet Communications Specification Guide 1.0 General 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 The electronic overload relay shall be available in NEMA and IEC contactor mount |
Original | ||||
| overload relay | The E3 Solid-State Overload Relay Reliable Early Warning Motor Protection Early Warning Motor Protection Can Help Improve Productivity To compete in the global economy, companies must maximize into a single protective device. Its solid-state design offers |
Original | ||||
| 592-ec | User Manual E3 and E3 Plus Solid-State Overload Relay Catalog Numbers 193/592-EC1, -EC2, -EC3, -EC5 Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from |
Original | ||||
| ptc probe | Motor thermal protection relay ■ ETM / ETM2 Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 : ■ Fault latching function ■ Pushbutton for local reset ■ Remote reset via external contact |
Original | ||||
| CEP7 Solid State Overload Relays Advanced solid | CEP7 Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of CEP7 solid state overload relays advances Sprecher + Schuh’s leading edge technology with several improved features. This second generation of CEP7 |
Original | ||||
|
|
||||||
| Motor Protection and Monitoring Motor Protection | Motor Protection and Monitoring Motor Protection Circuit Breaker 5.1 Monitoring Relays Product Overview—Monitoring Relays… Current Monitoring Relays… |
Original | ||||
| Selection Guide E300 Electronic Overload Relay | Selection Guide E300 Electronic Overload Relay Bulletin Numbers 193, 592 E300 Electronic Overload Relay What’s Inside Topic Page Bulletin 193/592-E300 Overview 3 Bulletin 193/592-E300 Product Selection 11 Sensing Modules 11 Control Modules 12 Accessories |
Original | ||||