NH2 FUSE AM Search Results
NH2 FUSE AM Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCKE800NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B | Datasheet | ||
| TCKE800NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B | Datasheet | ||
| TCKE805NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE805NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE812NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet |
Documents mentioning NH2 FUSE AM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| NH Fuse Links Littelfuse European style NH fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| nh fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| nh fuse | International Products NH Fuse Links 500 Volts • 2 – 630 Amperes Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation |
Original | ||||
| NH Fuse Links Littelfuse European style NH fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| International Products NH Fuse links 500 Volts • | International Products NH Fuse links 500 Volts • 2-630 Amperes Specifications Voltage Rating: 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage) |
Original | ||||
| International Products NH FUSE LINKS | International Products NH FUSE LINKS 500Volts•2-630Amperes Specifications 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage) |
Original | ||||
| iec 269-2-1 | POWR-GARD® Fuse Datasheet NH Fuse links 500 Volts • 2-630 A Specifications Voltage Rating 500 VAC 440 VDC Ampere Range 2-630 A Interrupting Rating 120 kA AC 25 kA DC Standards DIN 43.620, IEC 269-2-1 Approvals VDE Example part number NH1CG25 (size, characteristic and amperage) |
Original | ||||
| fuses a | NH KNIFE BLADE NH fuses are typically used for power distribution applications and to protect large electrical devices such as motors, drives, etc. They are available in seven sizes with a current range of 2 to 1600 Amps. NH fuses have knife blades at both ends, |
Original | ||||
| neozed | NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are |
Original | ||||
| neozed | NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are |
Original | ||||
| Sicherungen für den Halbleiter- und | Sicherungen für den Halbleiter- und Leitungsschutz gRL Fuse links for semiconductor and line protection gRL NH 000 NH 00 NN 1 NH 2 NH 3 x x x x x Sicherungen mit Schraubkontakten fuses with screwcontacts DIN 43653 AC 690 V AC 690 V AC 690 V AC 690 V AC 690 V |
Original | ||||
| Technical Data 720133 Effective April 2014 | Technical Data 720133 Effective April 2014 Supersedes January 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects. |
Original | ||||
| Technical Data 720133 Effective June 2014 | Technical Data 720133 Effective June 2014 Supersedes April 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects. |
Original | ||||
| Data Overcurrent Circuit B re a k e r Sheet | Data Overcurrent Circuit B re a k e r Sheet 410.073.270 Ers f. gl. Nr. v y.C T echnical C Data: Vo ltage r a tin g : AC 250 V; DC 65 V;3AC 415 V C urrent r a tin g range: main c i r c u i t 0 .0 5… 16 ( 0 .0 5…1 6 ) A Standard c u rre n t r a tin g range: |
OCR Scan | ||||
|
|
||||||
| galaxy power | dc Distribution and Battery Connections for GPS 4848, GPS 4812, GPS 4824, and GPS 2424 A variety of dc distribution and battery connection modules are available for use with the GALAXY Power Systems family to meet a wide range of applications. Preconfigured dc Distribution |
Original | ||||
| Film Capacitors Installation and maintenance | Film Capacitors Installation and maintenance instructions for thyristor modules TSM-HV series Series/Type: Ordering code: Thyristor modules TSM-HV B44066T….E690 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||
| galaxy power | Product Manual 167-792-150 Comcode 107933376 Issue 1 November 1996 Galaxy Power System 4824 (GPS 4824) Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change. |
Original | ||||
| Solar Circuit Protection Application Guide | Solar Circuit Protection Application Guide Complete and reliable solar circuit protection Introduction Benefits of Eaton’s Circuit Protection Solutions Complete and Reliable Circuit Protection for Photovoltaic (PV) Balance of System Eaton offers the industry’s most complete and reliable |
Original | ||||
| TABLE OF CONTENTS MINIATURE DIAZED 20 Amps. • | TABLE OF CONTENTS MINIATURE DIAZED 20 Amps. • NEOZED CYLINDER NH "Bottle" fuses in ve sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are Amps. 100 Amps. available in four sizes to 125 Amps, with or without blown • gL/gG - Slow Blow |
Original | ||||
NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow Medium Blow Fast Blow Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are |
Original | |||||
| Product Manual J85500T-1 Select Code 167-790-059 | Product Manual J85500T-1 Select Code 167-790-059 Comcode 107300592 Issue 4 October 1998 Lucent Technologies Lineage® 2000 Global Power System Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. |
Original | ||||
| hrc fuse holder | IEC & British Standard Fuses IEC and British Standard Fuses Section Contents Application Data Page Application Data… 217-218 HRC fuse holders CAMaster…235 |
Original | ||||
| bs1361 | Circuit Protection Solutions Low Voltage Fuse Links Catalogue Low Voltage Fuse Links Catalogue Table of Contents Domestic Applications to BS1361 & BS1312 Consumer Unit Fuse Link 4 Plug Top Fuse Links 4 Industrial & Motor Applications to BS88 Offset Bolted Tags |
Original | ||||
| Film Capacitors – Power Factor Correction | Film Capacitors – Power Factor Correction Thyristor Module Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: 2010-04-12 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||