Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NH2 FUSE AM Search Results

    NH2 FUSE AM Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Datasheet
    TCKE800NL
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Datasheet
    TCKE805NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Datasheet
    TCKE805NL
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Datasheet
    TCKE812NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Datasheet

    Documents mentioning NH2 FUSE AM

    Document Partial File Text Tags Type PDF
    NH Fuse Links Littelfuse European style NH fuse
    NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic
    Original PDF
    nh fuse
    NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic
    Original PDF
    nh fuse
    International Products NH Fuse Links 500 Volts • 2  –   630 Amperes Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation
    Original PDF
    NH Fuse Links Littelfuse European style NH fuse
    NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic
    Original PDF
    International Products NH Fuse links 500 Volts •
    International Products NH Fuse links 500 Volts • 2-630 Amperes Specifications Voltage Rating: 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage)
    Original PDF
    International Products NH FUSE LINKS
    International Products NH FUSE LINKS 500฀Volts฀•฀2-630฀Amperes Specifications 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage)
    Original PDF
    iec 269-2-1
    POWR-GARD® Fuse Datasheet NH Fuse links 500 Volts • 2-630 A Specifications Voltage Rating 500 VAC 440 VDC Ampere Range 2-630 A Interrupting Rating 120 kA AC 25 kA DC Standards DIN 43.620, IEC 269-2-1 Approvals VDE Example part number NH1CG25 (size, characteristic and amperage)
    Original PDF
    fuses a
    NH KNIFE BLADE NH fuses are typically used for power distribution applications and to protect large electrical devices such as motors, drives, etc. They are available in seven sizes with a current range of 2 to 1600 Amps. NH fuses have knife blades at both ends,
    Original PDF
    neozed
    NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are
    Original PDF
    neozed
    NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are
    Original PDF
    Sicherungen für den Halbleiter- und
    Sicherungen für den Halbleiter- und Leitungsschutz gRL Fuse links for semiconductor and line protection gRL NH 000 NH 00 NN 1 NH 2 NH 3 x x x x x Sicherungen mit Schraubkontakten fuses with screwcontacts DIN 43653 AC 690 V AC 690 V AC 690 V AC 690 V AC 690 V
    Original PDF
    Technical Data 720133 Effective April 2014
    Technical Data 720133 Effective April 2014 Supersedes January 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects.
    Original PDF
    Technical Data 720133 Effective June 2014
    Technical Data 720133 Effective June 2014 Supersedes April 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects.
    Original PDF
    Data Overcurrent Circuit B re a k e r Sheet
    Data Overcurrent Circuit B re a k e r Sheet 410.073.270 Ers f. gl. Nr. v y.C T echnical C Data: Vo ltage r a tin g : AC 250 V; DC 65 V;3AC 415 V C urrent r a tin g range: main c i r c u i t 0 .0 5… 16 ( 0 .0 5…1 6 ) A Standard c u rre n t r a tin g range:
    OCR Scan PDF
    galaxy power
    dc Distribution and Battery Connections for GPS 4848, GPS 4812, GPS 4824, and GPS 2424 A variety of dc distribution and battery connection modules are available for use with the GALAXY Power Systems family to meet a wide range of applications. Preconfigured dc Distribution
    Original PDF
    Film Capacitors Installation and maintenance
    Film Capacitors Installation and maintenance instructions for thyristor modules TSM-HV series Series/Type: Ordering code: Thyristor modules TSM-HV B44066T….E690 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
    Original PDF
    galaxy power
    Product Manual 167-792-150 Comcode 107933376 Issue 1 November 1996 Galaxy Power System 4824 (GPS 4824) Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change.
    Original PDF
    Solar Circuit Protection Application Guide
    Solar Circuit Protection Application Guide Complete and reliable solar circuit protection Introduction Benefits of Eaton’s Circuit Protection Solutions Complete and Reliable Circuit Protection for Photovoltaic (PV) Balance of System Eaton offers the industry’s most complete and reliable
    Original PDF
    TABLE OF CONTENTS MINIATURE DIAZED 20 Amps. •
    TABLE OF CONTENTS MINIATURE DIAZED 20 Amps. • NEOZED CYLINDER NH "Bottle" fuses in ve sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are Amps. 100 Amps. available in four sizes to 125 Amps, with or without blown • gL/gG - Slow Blow
    Original PDF
    NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow Medium Blow Fast Blow Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are
    Original PDF
    Product Manual J85500T-1 Select Code 167-790-059
    Product Manual J85500T-1 Select Code 167-790-059 Comcode 107300592 Issue 4 October 1998 Lucent Technologies Lineage® 2000 Global Power System Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing.
    Original PDF
    hrc fuse holder
    IEC & British Standard Fuses IEC and British Standard Fuses Section Contents Application Data Page Application Data… 217-218 HRC fuse holders CAMaster…235
    Original PDF
    bs1361
    Circuit Protection Solutions Low Voltage Fuse Links Catalogue Low Voltage Fuse Links Catalogue Table of Contents Domestic Applications to BS1361 & BS1312 Consumer Unit Fuse Link 4 Plug Top Fuse Links 4 Industrial & Motor Applications to BS88 Offset Bolted Tags
    Original PDF
    Film Capacitors – Power Factor Correction
    Film Capacitors – Power Factor Correction Thyristor Module Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: 2010-04-12 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
    Original PDF