NH2 FUSE Search Results
NH2 FUSE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCKE800NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B | Datasheet | ||
| TCKE800NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B | Datasheet | ||
| TCKE805NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE805NL | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B | Datasheet | ||
| TCKE812NA | Toshiba Electronic Devices & Storage Corporation | eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B | Datasheet |
Documents mentioning NH2 FUSE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| hrc fuse base | Product data sheet 3NX3107 MOULDED PLASTIC PUSH-ON COVERS FOR LV HRC FUSE BASE,SIZE 2 Similar to image Technical data: Installation size of fuse-link NH2 Accessories LV HRC contact cover Further information: Information- and Downloadcenter (Catalogs, Brochures,…) |
Original | ||||
| NH Fuse Links Littelfuse European style NH fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| nh fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| nh fuse | International Products NH Fuse Links 500 Volts • 2 – 630 Amperes Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation |
Original | ||||
| NH Fuse Links Littelfuse European style NH fuse | NH Fuse Links Littelfuse European style NH fuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse links are generally used to protect cables and installation lines from overload and short circuits. The aM characteristic |
Original | ||||
| International Products NH Fuse links 500 Volts • | International Products NH Fuse links 500 Volts • 2-630 Amperes Specifications Voltage Rating: 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage) |
Original | ||||
| International Products NH FUSE LINKS | International Products NH FUSE LINKS 500Volts•2-630Amperes Specifications 500 VAC 440 VDC Ampere Range: 2-630 A Interrupting Rating: 120 kA AC 25 kA DC Standards: DIN 43.620, IEC 60269-2-1 Approvals: VDE (gL – gG only) Example part number: NH1CG25 (size, characteristic and amperage) |
Original | ||||
| iec 269-2-1 | POWR-GARD® Fuse Datasheet NH Fuse links 500 Volts • 2-630 A Specifications Voltage Rating 500 VAC 440 VDC Ampere Range 2-630 A Interrupting Rating 120 kA AC 25 kA DC Standards DIN 43.620, IEC 269-2-1 Approvals VDE Example part number NH1CG25 (size, characteristic and amperage) |
Original | ||||
| fuses a | NH KNIFE BLADE NH fuses are typically used for power distribution applications and to protect large electrical devices such as motors, drives, etc. They are available in seven sizes with a current range of 2 to 1600 Amps. NH fuses have knife blades at both ends, |
Original | ||||
| neozed | NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are |
Original | ||||
| Sicherungen für den Halbleiter- und | Sicherungen für den Halbleiter- und Leitungsschutz gRL Fuse links for semiconductor and line protection gRL NH 000 NH 00 NN 1 NH 2 NH 3 x x x x x Sicherungen mit Schraubkontakten fuses with screwcontacts DIN 43653 AC 690 V AC 690 V AC 690 V AC 690 V AC 690 V |
Original | ||||
| Technical Data 720133 Effective April 2014 | Technical Data 720133 Effective April 2014 Supersedes January 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects. |
Original | ||||
| Technical Data 720133 Effective June 2014 | Technical Data 720133 Effective June 2014 Supersedes April 2014 Bussmann NH Photovoltaic fuse links Product description Bussmann’s range of NH size photovoltaic fuse links is specifically designed to protect and isolate photovoltaic array combiners and disconnects. |
Original | ||||
| neozed | NEXT FIND IT TABLE OF CONTENTS MINIATURE DIAZED Mini fuses in five sizes to 20 Amps. • Slow Blow • Medium Blow Click for PDF file • Fast Blow • Super Fast Blow NEOZED CYLINDER NH "Bottle" fuses in five sizes to 200 Compact fuses in three sizes to Standard cylinder fuses are |
Original | ||||
|
|
||||||
| Special Purpose Fuses Special Purpose Fuses | Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses Isolating fuse list Imax (kA) one pulse Designation Reference Number Voltage rating (V) Current rating (A) Breaking capacity 1 1 2.5 2.5 3 4.5 4.5 5 5 6.5 6.5 8-10 8-10 8-10 |
Original | ||||
| accessories | DIAZED AND NEOZED ACCESSORIES SCREW CAP The Screw Cap types offered fit the various fuse and Fuse Base sizes. They hold the fuses in place and connect the head of the fuse with the load side of the Fuse Holder. The colored blown fuse indicator on the head of the fuse is |
Original | ||||
| Special Purpose Fuses Special Purpose Fuses | Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses PROTECTION AGAINST LOW VOLTAGE ARRESTER FAILURE When an arrester fails (it can no longer contain overvoltage and thus short circuits), a fuse is needed to prevent its explosion. If the fuse is equipped with a trip-indicator, the user will be aware that the arrester |
Original | ||||
| Data Overcurrent Circuit B re a k e r Sheet | Data Overcurrent Circuit B re a k e r Sheet 410.073.270 Ers f. gl. Nr. v y.C T echnical C Data: Vo ltage r a tin g : AC 250 V; DC 65 V;3AC 415 V C urrent r a tin g range: main c i r c u i t 0 .0 5… 16 ( 0 .0 5…1 6 ) A Standard c u rre n t r a tin g range: |
OCR Scan | ||||
| nh fuse | Gears & Fuse Gears Gears & Fuse Gears IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 690 VAC and 440 VDC. They are in compliance with IEC 60269, DIN VDE 0636, part 21, 201 and DIN 43620 (dimensions). |
Original | ||||
| carton | Part Number Carton Quantity Weight per Carton (kg) Volume per Carton (cc) FEEDER PILLAR MJ25 10 1.55 737 MJ29 5 0.97 737 MJ30 (up to 200a) 10 1.56 1345 MJ31 (up to 200a) 10 2.4 1666 250/315 MJ30 5 1.1 880 250/315 MJ31* 5 1.48 1120 PJ30 5 1.1 880 PJ31 5 1.48 |
Original | ||||
| Film Capacitors Installation and maintenance | Film Capacitors Installation and maintenance instructions for thyristor modules TSM-HV series Series/Type: Ordering code: Thyristor modules TSM-HV B44066T….E690 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||
| galaxy power | dc Distribution and Battery Connections for GPS 4848, GPS 4812, GPS 4824, and GPS 2424 A variety of dc distribution and battery connection modules are available for use with the GALAXY Power Systems family to meet a wide range of applications. Preconfigured dc Distribution |
Original | ||||
| Film Capacitors – Power Factor Correction | Film Capacitors – Power Factor Correction Thyristor Module Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: 2010-04-12 4 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||
| Film capacitors – Power Factor Correction Key | Film capacitors – Power Factor Correction Key components – Thyristor module TSM-HV Series/Type: Ordering code: TSM-HV200 B44066T0200E690 Date: Version: June 2012 6 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the |
Original | ||||