nanalem
Abstract: nana transducers
Contextual Info: Current Transducers NNC-920 . 960A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 2000 . 6000 A Electrical data
|
Original
|
NNC-920
50/60Hz,
nanalem
nana
transducers
|
PDF
|
nanalem
Abstract: nana DCVT-25V10 voltage transducer dcvt UPS CIRCUT DCVT2
Contextual Info: Voltage Transducer DCVT-25V10 VPN = 25 V For the electronic measurement of voltages : DC with a galvanic isolation between the primary circuit and the secondary circuit. Preliminary Electrical data VPN VP Vout RIN KN Vd Primary nominal r.m.s. voltage Primary voltage, measuring range
|
Original
|
DCVT-25V10
25V10
nanalem
nana
DCVT-25V10
voltage transducer
dcvt
UPS CIRCUT
DCVT2
|
PDF
|
nanalem
Abstract: nana nanalem hnc
Contextual Info: Current Transducer HNC- 050 . 100P IPN = 50 . 100 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Primary nominal
|
Original
|
50/60Hz,
nanalem
nana
nanalem hnc
|
PDF
|
LTSR 6-NP
Abstract: LTSR 25-NP ch-1228 nanalem lem lt 100 p LTS 25-NP hall current transducer lts 6-np LEM hall effect sensor voltage offset cancellation LTSR 15-NP LA 25-NP
Contextual Info: Technical Information LTSR: ASIC Based Closed-Loop Transducers from 6 A up to 25 A nominal with reference access LTSR: ASIC Based Closed-Loop Transducers from 6 A up to 25 A nominal with reference access. By Stéphane Rollier, Christophe Benz & Hans Dieter Huber.
|
Original
|
25-NP
c4-0021
ROC-10483
CH-1228
LTSR 6-NP
LTSR 25-NP
nanalem
lem lt 100 p
LTS 25-NP
hall current transducer lts 6-np
LEM hall effect sensor voltage offset cancellation
LTSR 15-NP
LA 25-NP
|
PDF
|
nanalem
Abstract: nana HNC-40CA
Contextual Info: IPN = 400 A Current Transducer HNC-40CA For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN Primary nominal DC or rms current
|
Original
|
HNC-40CA
50/60Hz,
nanalem
nana
HNC-40CA
|
PDF
|
nanalem
Abstract: nana 050PV FA-050 DC Power Supplies circuit
Contextual Info: Current Transducer FA-050 . 100PV IPN = 50 . 100 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Primary nominal
|
Original
|
FA-050
100PV
050PV
AC50/60Hz,
nanalem
nana
050PV
FA-050
DC Power Supplies circuit
|
PDF
|