Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NAMUR NE 43 Search Results

    NAMUR NE 43 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    kha6-sr2-ex

    Abstract: namur NE 21 KFD2-SR2-Ex2.W KFA6-SR2-EX2.W kfd2-sr-ex2 Ex-94 VDE 0812 PTB VDE 0812 S KHA5-S lb 7610
    Contextual Info: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K - 2-kanalig Eingang Ι EEx ia IIC -SR2-Ex2.W Ausgang: Relais Eingang ΙΙ EEx ia IIC - Steuerstromkreis EEx ia IIC - 1 Signalausgang mit 1 Wechsler je Kanal 1+ 3- 4+ 6Schalter S3 in Pos. Ι - EMV gemäß NAMUR NE 21


    Original
    PDF

    DW-AD-405-M5

    Abstract: DW-AD-403-M5 DW-AD-401-M5 DW-AD-404-M5 DW-AS-403-M5 DW-AS-402-M5 DW-AD-402-M5 DW-AS-401-M5 DW-AS-404-M5 IEC 61000-4-3 level
    Contextual Info: data sheet Induktiver Näherungsschalter Détecteur de proximité inductif Inductive Proximity Switch DW - A - 40 - M5 Durchmesser Diamètre Diameter M5 Schaltabstand Portée Operating distance Einbau Montage Mounting 0,8 mm Miniaturausführung Gehäuse zylindrisch M5


    Original
    PDF

    DW-AS-403-M5

    Abstract: DW-AD-404-M5 DW-AS-404-M5 DW-AD-401-M5 DW-AD-402-M5 DW-AD-403-M5 DW-AS-401-M5 DW-AS-402-M5 fe360 DW-AD-40
    Contextual Info: data sheet Certified I SO 9 M5 Schaltabstand Portée Operating distance 0,8 mm Miniaturausführung Gehäuse zylindrisch M5 Appareil miniature Boîtier cylindrique M5 Miniature device Cylindrical housing, M5 Wichtigste Eigenschaften: Caractéristiques princi­pales:


    Original
    400-M5 DW-AS-403-M5 DW-AD-404-M5 DW-AS-404-M5 DW-AD-401-M5 DW-AD-402-M5 DW-AD-403-M5 DW-AS-401-M5 DW-AS-402-M5 fe360 DW-AD-40 PDF

    DW-AD-403-04

    Abstract: DW-AD-401-04 detecteur de proximite inductif DW-AD-404-04 DW-AD-402-04 DW-AS-401-04 DW-AS-402-04 DW-AS-404-04 Contrinex namur DW-AS-405-04
    Contextual Info: data sheet Induktiver Näherungsschalter Détecteur de proximité inductif Inductive Proximity Switch DW - A - 40 - 04 Durchmesser Diamètre Diameter 4 mm Miniaturausführung Durchmesser 4 mm glatt Appareil miniature Boîtier lisse de 4 mm de diamètre Wichtigste Eigenschaften:


    Original
    PDF

    pbt-gf20 relay

    Abstract: PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X
    Contextual Info: Selection Guide Housing Styles Pages Q5.5 Style 2-Wire DC 3-Wire DC 7-8 9 - 10 Q06 Style 3-Wire DC 11 - 12 Housing Styles Pages Q11S Style 2-Wire DC 3-Wire DC 2-Wire NAMUR 7-8 23 - 24 45 - 46 25 - 26 37 - 38 Q6.5 and Q9.5 Styles 3-Wire DC 13 - 14 Q12 Style


    Original
    B9005 1-800-544-PROX B0143 pbt-gf20 relay PA-GF20 BI50-Q80-ADZ30X2-B1131 Ni10-Q25-AN6X M160160 2-Q12-AN6X Lucas Ni15-Q30-AP6X Ni25-Q20-AP6X2-H1141 4-Q12-AP6X PDF

    encodeur incremental

    Abstract: TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique
    Contextual Info: Phoenix Contact GmbH & Co. KG D-32823 Blomberg, Germany Fax +49- 0 5235-341200, Tel. +49-(0)5235-300 www.interface.phoenixcontact.com D GB TNR 9000681-03 / 04.2003 Universal Frequenz-Messumformer Universal Frequency Transducer F Convertisseur de fréquences


    Original
    D-32823 CISPR11 encodeur incremental TRANSISTOR SUBSTITUTION Convertisseur Tension Frequence MCR-F-UI-DC Conector N macho convertidor de frecuencia transitor engranaje BU 2525 AF analogique PDF

    rosemount temperature sensors

    Abstract: rosemount pt 100 PT-100 RTD 4 wire sensor - rosemount PT-100 RTD 3 wire sensor - rosemount rosemount pt 100 rtd rosemount calibration rosemount calibration pt 100 Rosemount RTD Rosemount ni mh
    Contextual Info: Product Data Sheet 00813-0100-4148, Rev BA May 2008 Rosemount 148 Rosemount 148 Temperature Transmitter • Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions CPS • Increases measurement accuracy and


    Original
    00813-XXXX-XXXXm¤ rosemount temperature sensors rosemount pt 100 PT-100 RTD 4 wire sensor - rosemount PT-100 RTD 3 wire sensor - rosemount rosemount pt 100 rtd rosemount calibration rosemount calibration pt 100 Rosemount RTD Rosemount ni mh PDF

    MCR-SL-PT100-LP-I

    Abstract: PT100 application note RTD PT100 3wire PT100 SENSOR pt100 thermometer PT100 temperature transducer 3 wire PT100 IEC 751 pt100 sensors application note pt100 pt100 sensor 2wire
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the


    Original
    PT100 MCR-SL-PT100-LP-I MCR-SL-PT100-LP-I PT100 application note RTD PT100 3wire PT100 SENSOR pt100 thermometer PT100 temperature transducer 3 wire PT100 IEC 751 pt100 sensors application note pt100 pt100 sensor 2wire PDF

    pt100 atex

    Abstract: AGLF NGV220-EX ABB Pt100 3 wire agsfd Thermocouple Type K Thermocouple color codes cable Ni100 sensor NGV220-NO Ni120 sensor
    Contextual Info: Data Sheet 10/11-8.69 EN Field mounted Temperature Transmitter TF202/TF202-Ex FOUNDATION Fieldbus H1, Pt 100 RTD , thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit


    Original
    TF202/TF202-Ex pt100 atex AGLF NGV220-EX ABB Pt100 3 wire agsfd Thermocouple Type K Thermocouple color codes cable Ni100 sensor NGV220-NO Ni120 sensor PDF

    RTD PT100 3wire

    Abstract: MCR-SL-PT100-LP-I pt100 4-20mA pt100 temperature transducers rtd pt100 4-20ma connections MCR-SL-PT100 namur NE 43 pt100 temperature sensor circuit connection Pt100 3 wire Phoenix/pt100 4-20 ma
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4wire technology – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the


    Original
    PT100 MCR-SL-PT100-LP-I RTD PT100 3wire MCR-SL-PT100-LP-I pt100 4-20mA pt100 temperature transducers rtd pt100 4-20ma connections MCR-SL-PT100 namur NE 43 pt100 temperature sensor circuit connection Pt100 3 wire Phoenix/pt100 4-20 ma PDF

    relay 12v 500 ohm

    Abstract: zhrv3 1.1kw 3phase 220v
    Contextual Info: SENSORS, PROCESS & MEASUREMENT Short Form Catalogue 2014 I 2015 www.acdc.co.za CONTENTS DIN Rail Mount Voltage Monitors Power Monitors SP-100/SP-103: Current Monitor, Single Phase SP-101/SP-104: Current Monitor, Single Phase SP-120/SP-123: Current Window Comparator, Single Phase


    Original
    SP-100/SP-103: SP-101/SP-104: SP-120/SP-123: SP-121: SP-200/SP-201: SP-220/SP-221: AP-221: AP-224: SP-230/SP-231/SP-232: AP-231/AP-232: relay 12v 500 ohm zhrv3 1.1kw 3phase 220v PDF

    ABB Pt100 3 wire

    Abstract: pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum
    Contextual Info: FieldIT Data Sheet 10/11-8.25 EN Head mounted Temperature Transmitter TF02/TF02-Ex FOUNDATION Fieldbus H1, Pt 100 RTD , thermocouples, 1 or 2 independent channels • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit


    Original
    TF02/TF02-Ex ABB Pt100 3 wire pt100 temperature sensor circuit diagram TF02 Ni100 sensor 455 3968 PT100 PT100 temperature sensor ABB PT100 ABB ABB thermocouple pt100 4 wire BUZH, Aluminum PDF

    PT100 application note

    Abstract: pt100 sensors PT100 IEC B pt100 thermometer RTD PT100 3wire application note pt100 PT100 temperature transducer 3 wire PT100 temperature sensor class B pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-HT-PT100-I 1. Brief Description – For PT100 resistance thermometers in 2, 3 or 4-wire technology – For installation in Form B connection head ϑ POWER I SL Dimensional drawing for MCR-FL-HT-PT100-I


    Original
    PT100 MCR-SL-HT-PT100-I MCR-FL-HT-PT100-I PT100 application note pt100 sensors PT100 IEC B pt100 thermometer RTD PT100 3wire application note pt100 PT100 temperature transducer 3 wire PT100 temperature sensor class B pt100 temperature sensor circuit connection MCR-SL-HT-PT100-I PDF

    IEC-60751

    Abstract: IEC60751 DIN 43710 namur NE 43 DK-8410 e988 60584 namur NE 21 Pt100 transmitter 4.20 mA Pt100 transmitter
    Contextual Info: PReasy 4114 UNIVERSAL TRANSMITTER 5 Input for RTD, TC, Ohm, potentiometer, mA and V 2-wire supply > 16 V FM-approved for installation in Div. 2 Output for current and voltage Universal AC or DC supply Advanced features: • Programmable by way of detachable display front


    Original
    2004/108/EC 2006/95/EC 4114Y103-UK IEC-60751 IEC60751 DIN 43710 namur NE 43 DK-8410 e988 60584 namur NE 21 Pt100 transmitter 4.20 mA Pt100 transmitter PDF

    ni500 DIN 43760

    Abstract: Resistance characteristic Ni1000 PT500 IEC 751 Resistance characteristic Pt1000 PT100 IEC 751 accuracy Ni100 sensor ni1000 DIN 43760 W5Re-W26Re pt100 4-20 ma RTD PT1000 conversion
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer MCR-FL-T-LP-I 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – Can be mounted on symmetrical EN 50 022 DIN rails Temperature – Can be freely programmed using the


    Original
    PDF

    Contextual Info: 9116B UNIVERSAL CONVERTER ∙ Input for RTD, TC, Ohm, potentiometer, mA and V ∙ Supply for 2-wire transmitters ∙ Active / passive mA output and relay output ∙ Can be supplied separately or installed on power rail, PR 9400 ∙ SIL 2-certified via Full Assessment


    Original
    9116B 5910Ex PDF

    PT100 temperature sensor JUMO

    Abstract: digital thermometer 52 W5Re-W26Re pt100 sensor 2-wire interface pt100 calibration certificate namur NE 43 MoRe5-MoRe41 Thermocouple type PT100 dtrans converter type PT100 jumo
    Contextual Info: M. K. JUCHHEIM GmbH & Co Postadresse: Telefon: Telefax: E-Mail: Internet: 36035 Fulda, Germany 06 61 60 03-7 25 (06 61) 60 03-6 81 mail@jumo.net www.jumo.de United Kingdom JUMO Instrument Co. Ltd. Temple Bank, Riverway GB-Harlow, Essex CM20 2TT Phone: (0 12 79) 53 55 33


    Original
    TTL/RS232 PT100 temperature sensor JUMO digital thermometer 52 W5Re-W26Re pt100 sensor 2-wire interface pt100 calibration certificate namur NE 43 MoRe5-MoRe41 Thermocouple type PT100 dtrans converter type PT100 jumo PDF

    free transistor

    Abstract: KFU8-UFC-EX 1.D k-adp1 kfu8-ufc-ex1 ATEX 1471 IEC 60947-5-6 KFU8-UFC-EX namur NE 93 VDE 0106 DIN EN 50014 STANDARD
    Contextual Info: Frequency Current Converters with Limit Value KFU8-UFC-Ex1* 1+ 10 k 3- 1+ Hazardous area Input EEx ia IIC 3400 Ω ≤ R ≤ 2 kΩ 1+ 3- 1+ 10 k 3- Safe area RS 232 3- PC Signal procesor TTL yellow/ red green Error yellow Start bridge KFU8-UFC-Ex1.D 19+ 20-


    Original
    PDF

    NI500 temperature

    Abstract: PT100 4 wire temperature sensor Ni100 sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor
    Contextual Info: Programmable Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I Dimensional drawing for MCR-FL-HT-T-I


    Original
    PT100 NI500 temperature PT100 4 wire temperature sensor Ni100 sensor PT500 IEC 751 Resistance characteristic Pt1000 PT500 temperature sensor PT500 sensor PtRh10-Pt Ni1000 temperature sensor PT100 2 wire temperature sensor PDF

    PT500 temperature sensor

    Abstract: PT500 IEC 751 W5Re-W26Re IEC 751 PT500 SENSOR MoRe5-MoRe41 Phoenix Ni1000 2-wire Pt1000 transmitter 4.20 mA PT500 PT1000 thermocouple
    Contextual Info: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-T-LP-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – Can be mounted on symmetrical EN 50 022 DIN rails Temperature


    Original
    eebt02 PT500 temperature sensor PT500 IEC 751 W5Re-W26Re IEC 751 PT500 SENSOR MoRe5-MoRe41 Phoenix Ni1000 2-wire Pt1000 transmitter 4.20 mA PT500 PT1000 thermocouple PDF

    hart protocol

    Abstract: Resistance characteristic Pt1000 Pt1000 RTD Sensor Resistance characteristic Ni1000 ni1000 DIN 43760 Pt100 transmitter 4.20 mA Resistance thermometer mw Thermocouple Type K linearization PT1000 PT500
    Contextual Info: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HARTProtocol MCR-FL-HT-TS-I-Ex 1. Description – For resistance thermometers, thermocouples, and resistance and voltage sensors POWER FL I Dimensional drawing for MCR-FL-HT-TS-I-Ex


    Original
    PDF

    Resistance characteristic Pt1000

    Abstract: PT100 SENSOR rtd sensor pt100 temperature transmitter pt100 4-20ma atex Resistance characteristic Ni1000 PT1000 PT500 PT1000 thermocouple PT500 IEC 751 PT500 temperature sensor
    Contextual Info: Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I-Ex 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I


    Original
    PDF

    relais bv 20.1

    Contextual Info: Rapide, fiable, ultra précis. My-Com. Commutateurs de précision ± 1 m. Précision du seuil de commutation de ±1 µm non encore égalée Placer des points de référence, surveiller des tolérances, contrôler, ajuster de façon rapide, fiable et avec grande


    Original
    CH-8501 FR-74250 relais bv 20.1 PDF

    Temperature sensor using plc

    Abstract: oven rtd sensor 7 segment display control pc using RS232 N905
    Contextual Info: 850 851 R.100.616 Process transmitter/Process controller CODIX 850/851 Features and benefits: • All common analogue measurement signals can be directly connected bipolar voltage and current, thermocouple, RTD, resistance • Adjustable set point with two changeover contacts


    Original
    RS232 D-78023 Temperature sensor using plc oven rtd sensor 7 segment display control pc using RS232 N905 PDF