Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MS33649 Search Results

    Documents mentioning MS33649

    Document Partial File Text Tags Type PDF
    sensotec
    www.honeywell.com/sensotec Accessories MATING CONNECTORS AND CONNECTOR/CABLE ASSEMBLIES Mating Connector Selection Chart 1-800-848-6564 Connector/Cable Assemblies Your Transducer Mating Unamplified Output Voltage 3-Wire Electrical Termination Connector Only 6 Conductor* 4 Conductor*
    Original PDF
    trans metrics
    trans metrics , Division of United Electric Controls Low Pressure Transducer P020 Series FEATURES: • High accuracy • 0-2 thru 0-10 PSI pressure ranges • 0-5 VDC, 1-5 VDC, 1-2 mV/V or 4-20 mA output • 2, 3 or 4-wire circuitry • Integral electronics
    Original PDF
    gt1000
    SERIES GT1000 0-5 Vdc PRESSURE TRANSDUCER Bonded Foil Strain Gage DESCRIPTION The STI Series GT1000 is a 0-5 Vdc output, reliable rugged pressure transducer, with a high frequency response, for measuring dynamic and static pressures. Available in absolute or sealed gage zero pressure reference, the major design feature is a fully cleanable pressure cavity. Other features of
    Original PDF
    differential pressure transducer
    SERIES DT400 DIFFERENTIAL PRESSURE TRANSDUCER DESCRIPTION The STI Series DT400 is a reliable, rugged, wet-wet differential pressure transducer, with a high line pressure capability, for measuring static differential pressures. The major design feature is a high differential overload pressure capability. Other features of design include removable pressure caps for
    Original PDF
    HIGH ACCURACY ELECTRONIC BAROMETER Model
    HIGH ACCURACY ELECTRONIC BAROMETER Model PX02K1-26A5T, Connector Style, Shown Smaller Than Actual Size PX02 Series Electronic Barometer 0-5 Vdc or 4-20 mA Output 3 Ranges Available 16 to 32 inHg – 406 to 813 mmHg 26 to 32 inHg – 660 to 813 mmHg 28 to 32 inHg – 711 to 813 mmHg
    Original PDF
    Model DS Digital/Analog Output Pressure Sensor
    Model DS Digital/Analog Output Pressure Sensor Order Code (see table below) n n n 0.1% Accuracy Including Temperature 1200 Hz Analog Response 380 Readings/ second Digital Output Order Code: Outputs: 0-5 VDC and RS-232 Outputs: 0-5 VDC and RS-485 Gage AP611
    Original PDF
    Pressure Accessories Test & Measurement Sensors
    Pressure Accessories Test & Measurement Sensors DESCRIPTION Honeywell provides a wide range of accessories for our test and If you don’t see exactly what you need listed below, or have measurement sensor products, which are designed to meet ad- special requirements for your particular application or operating
    Original PDF
    T E M P O S O N I C S ® INSTALLATION I I I
    T E M P O S O N I C S ® INSTALLATION I I I DEVICENET OUTPUT 550652 B W I R I N G D6 Connector Pin No. 1 2 3 4 5 Function Shield + 24 Vdc (customer provided) DC Ground CAN-H (dominant high) CAN-L (dominant low) CAUTION! When wiring Temposonics III sensors,
    Original PDF
    550571
    T E M P O S O N I C S ® L INSTALLATION S E R I E S D I G I T A L O U T P U T 550571 C S P E C I F I C A T I O N S PARAMETER S P E C I F I C AT I O N Measured Variable: Resolution: Non-Linearity✵: Displacement 1 ÷ [gradient x crystal freq. (mHz) x circulations]
    Original PDF
    550573
    T E M P O S O N I C S ® INSTALLATION I I I C A N B U S O U T P U T 550573 B W I R I N G - C A N b u s O U T P U T S CONNECTORS RG Connector 3 Pin No. 1 2 3 4 5 6 7 Wire Color Gray Pink Yellow Green Red or Brown White - Function CAN-L CAN-H No Connection No Connection
    Original PDF
    potentiometric pressure transducer
    Model 2-20 Low Range Potentiometric Pressure Transducer BEI Edcliff Instruments Division The Model 2-20 is designed for use in a broad variety of applications where accurate, reliable, low-pressure measurement is required. The 2-20 Pressure Transducer utilizes a Ni-Span-C corrugated
    Original PDF
    pressure products PWC – Pressure Transmitter
    pressure products PWC – Pressure Transmitter circuit) or optional 0–10 VDC. The PWC is available in pressure ranges from vacuum to 5,000 psi, gage or absolute. The PWC uses silicon strain gages in a full bridge circuit bonded to a stainless steel diaphragm. The output from the
    Original PDF
    SERIES DT2400 DIFFERENTIAL PRESSURE TRANSDUCER /
    SERIES DT2400 DIFFERENTIAL PRESSURE TRANSDUCER / 10,000 PSI LINE DESCRIPTION The STI Series DT2400 is a reliable, rugged, wet-wet differential pressure transducer with a 10,000 PSI line pressure capability, for measuring static differential pressures. The major design feature is the high line pressure rating. Other features of design include removable pressure caps for inspection
    Original PDF
    Model DS Digital Output Pressure Sensor
    Model DS Digital Output Pressure Sensor DESCRIPTION The Model DS offers the “smart” combination of microprocessor- second on the digital output, the Model DS provides the speed based, internal signal conditioning and micromachined silicon required for dynamic automotive or aerospace applications. With
    Original PDF
    Model A-5 General Purpose Gage/Absolute Pressure
    Model A-5 General Purpose Gage/Absolute Pressure Transducer DESCRIPTION Model A-5 pressure transducers are all-welded stainless steel automatic set up with the Model SC four-or-twelve channel digital sensors built for rugged industrial applications that require high
    Original PDF
    DIFFUSED SEMICONDUCTOR PRESSURE TRANSDUCER PX6000
    DIFFUSED SEMICONDUCTOR PRESSURE TRANSDUCER PX6000 Series mV/V Output 0-15 to 0-300 psi 0-1 to 0-20 bar MADE IN USA NIST PX6000 Model PX6000L1-100G Shown Actual Size 420 $ Applications ߜ Automotive Test ߜ Research & Development ߜ Engineering Test & Evaluation
    Original PDF
    HIGH PERFORMANCE PRESSURE TRANSDUCER LONG TERM
    HIGH PERFORMANCE PRESSURE TRANSDUCER LONG TERM RELIABILITY PX5500 Series mV/V Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar Applications ߜ Testing ߜ R&D/Engineering Test Laboratories ߜ Functional Test Systems ߜ Production Testing ߜ Product Quality Assurance
    Original PDF
    HIGH PERFORMANCE PRESSURE TRANSDUCER LONG TERM
    HIGH PERFORMANCE PRESSURE TRANSDUCER LONG TERM RELIABILITY MADE IN USA NIST PX5500 Model Shown PX5500 Series 0-5Vdc Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93 in-Hg = 760.2 mm-Hg = 1.014 bar
    Original PDF
    lvdt
    ACCESSORIES Accessories Honeywell provides a wide range of accessories for the pressure, load, torque, accelerometers, displacement transducers (LVDT), digital gages and instrumentation products, which are designed to meet additional requirements for most customer applications. Accessories can range from
    Original PDF
    pressure transmitter
    SERIES DT1450 4-20 mA DIFFERENTIAL PRESSURE TRANSMITTER DESCRIPTION The STI Series DT1450 is a reliable, rugged, 4-20 mA output, wet-wet differential pressure transmitter, with a high line pressure capability, for measuring static differential pressures. The major design feature is a high differential overload pressure capability. Other features of design include removable
    Original PDF
    Model Z General Purpose Gage/Absolute Pressure
    Model Z General Purpose Gage/Absolute Pressure Transducer DESCRIPTION Model Z pressure transducers are all-welded stainless steel automatic set up with the Model SC four-or-twelve channel digital sensors built for rugged industrial applications that require
    Original PDF
    potentiometric pressure transducer
    Model 2-40 High Pressure Potentiometric Pressure Transducer BEI Edcliff Instruments Division The Model 2-40 Pressure Transducer is designed for use in a variety of applications where accurate, reliable, high-pressure measurement is required. The 2-40 Pressure Transducer ultilizes a Ni-Span-C helical
    Original PDF
    550572
    T E M P O S O N I C S ® INSTALLATION I I I A N A L O G O U T P U T 550572 B W I R I N G - A N A L O G O U T P U T S CONNECTORS D6 Connector: RG Connector: Pin No. Wire Color 1 Gray Function Output #1 (Displacement) * 0 to 10 Vdc, 10 to 0 Vdc 4 to 20 mA, 20 to 4 mA,
    Original PDF