Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MOLECTRON POWER MAX Search Results

    MOLECTRON POWER MAX Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-SFP28LPB1W-0DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFP28LPB1W-3DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption PDF
    SF-100GLB1.5W-6DB
    Amphenol Cables on Demand Amphenol SF-100GLB1.5W-6DB QSFP 100G Loopback Adapter Module for QSFP28 Port Testing - 6dB Attenuation & 1.5W Power Consumption [100-Gigabit Ethernet Ready] PDF
    SF-QSFPLOOPBK-003
    Amphenol Cables on Demand Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] PDF

    Documents mentioning MOLECTRON POWER MAX

    Document Partial File Text Tags Type PDF
    pyroelectric
    QD-4.20 A P5 Ultra-fast Pyroelectrics D e scrip tio n T h e P 5 P y roelectric D e te cto r is an ultra-fast, tim e-resolved d etecto r of pu lsed radiation. T his ro o m te m p e r­ atu re p yroelectric d e te c to r a ch iev es 5 0 0 ps rise tim es with sp ectral re ­
    OCR Scan PDF
    joulemeter
    NE ! W JOULE MAX11 High Damage Threshold Pyroelectric Joulemeter Probe Features n n n n n n n n n n Damage Threshold: 300 mJ/cm2 at 1.06 µm 11 mm Diameter Sensor Area Broad Spectral Response: 0.1 to 1.1 µm Sensitive Range: 0.1 mJ to 300 mJ Rep Rate: 1 to 50 pps
    Original PDF
    P3 Versatile Pyroelectric Applications • Tim
    P3 Versatile Pyroelectric Applications • Tim e-resolved pow er m easu rem en t of pulsed, ch op p ed , or Q -sw itch ed la se r rad iation . • L aser pulse sh ap e m on itorin g • Flash lam p pulse m on ito rin g • L aser quality co n tro l • L aser safety m on itorin g
    OCR Scan PDF
    j25/j50
    Features / / m ////tnwnim J25/J50 Series Pyroelectric Joulemeter a Large area detector a Flat spectral response 0.1 to 100 ¡urn a Wide dynamic range fromjuJ to J a High rep rate to 400 pps a NIST traceable CAL in V/J a Replaceable detector element a Excellent EMI shielding
    OCR Scan PDF
    quadrant detector
    s PQD Series Pyroelectric PQ Quadrant Detectors width and either a 5 mm dia­ meter or 20 mm square detector. Models Q5, Q9 Detectors These are 5 mm and 9 mm diameter LiTa0.j Pyroelectric Quadrant Detectors with 0.05 mm element separation. They are mounted in a manner which
    OCR Scan PDF