MLX9061 Search Results
MLX9061 Datasheets (57)
Select Manufacturer
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MLX90614 | Melexis | Single and Dual Zone Infra Red Thermometer | Original | 659.92KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614 | Melexis | Single and Dual Zone Infra Red Thermometer in TO-39 | Original | 659.92KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614 | Melexis | Single and Dual Zone Infra Red Thermometer | Original | 1.23MB | 35 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614 | Melexis | Single and Dual Zone | Original | 659.91KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614AAA | Melexis | Single and Dual Zone Infra Red Thermometer | Original | 1.23MB | 35 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614BAA | Melexis | Single and Dual Zone Infra Red Thermometer | Original | 1.23MB | 35 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-AAA | Melexis | Single and Dual Zone | Original | 659.92KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-AAA | Melexis | Single and Dual Zone Infra Red Thermometer in TO-39 | Original | 659.92KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-AAA-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-AAA-000-TU | Melexis | Temperature Sensors, Transducers, Sensors, Transducers, IC THERMOMETER IR 5V TO-39 | Original | 52 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ABA-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ABA-000-TU | Melexis Technologies | Integrated Circuits (ICs) - PMIC - Thermal Management - THERMOMETER IR DUAL 5V TO-39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACA-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACA-000-TU | Melexis | Temperature Sensors, Transducers, Sensors, Transducers, IC IR THERM SENSOR P&P 5V TO-39 | Original | 52 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACC-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACC-000-TU | Melexis | Temperature Sensors, Transducers, Sensors, Transducers, IC IR THERMOMETER 5V TO-39 | Original | 52 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACF-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-ACF-000-TU | Melexis | Temperature Sensors, Transducers, Sensors, Transducers, THERMOMETER IR 5V TO-39 | Original | 52 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-BAA | Melexis | Single and Dual Zone Infra Red Thermometer in TO-39 | Original | 659.93KB | 40 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MLX90614ESF-BAA-000-SP | Melexis Technologies | Sensors, Transducers - Temperature Sensors - Analog and Digital Output - SENSOR DGTL -40C-85C TO39 | Original | 2.07MB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MLX9061 Price and Stock
Melexis Microelectronic Integrated Systems
Melexis Microelectronic Integrated Systems MLX90614ESF-BCI-000-TUTemperature Sensor Digital Serial (2-Wire, SMbus) Automotive 4-Pin TO-39 |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MLX90614ESF-BCI-000-TU | 851 | 1 |
|
Buy Now | ||||||
|
MLX90614ESF-BCI-000-TU | 1,497 |
|
Buy Now | |||||||
|
MLX90614ESF-BCI-000-TU | 851 | 12 Weeks | 1 |
|
Buy Now | |||||
|
MLX90614ESF-BCI-000-TU | 50 |
|
Buy Now | |||||||
Melexis Microelectronic Integrated Systems MLX90614ESF-BCH-000-TUTemperature Sensor Digital Serial (2-Wire, SMbus) Automotive 4-Pin TO-39 |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MLX90614ESF-BCH-000-TU | 639 | 639 |
|
Buy Now | ||||||
|
MLX90614ESF-BCH-000-TU | 1,264 |
|
Buy Now | |||||||
Melexis Microelectronic Integrated Systems MLX90614ESF-BCC-000-TUTemperature Sensor Digital Serial (2-Wire, SMbus) 4-Pin TO-39 |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MLX90614ESF-BCC-000-TU | 585 | 1 |
|
Buy Now | ||||||
|
MLX90614ESF-BCC-000-TU | 585 | 12 Weeks | 1 |
|
Buy Now | |||||
|
MLX90614ESF-BCC-000-TU | 50 |
|
Buy Now | |||||||
|
MLX90614ESF-BCC-000-TU | 14,314 |
|
Get Quote | |||||||
|
MLX90614ESF-BCC-000-TU | 2,752 |
|
Buy Now | |||||||
Melexis Microelectronic Integrated Systems MLX90614ESF-DCA-000-TUTemperature Sensor Digital Serial (2-Wire, SMbus) Automotive 4-Pin TO-39 |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MLX90614ESF-DCA-000-TU | 165 | 55 |
|
Buy Now | ||||||
|
MLX90614ESF-DCA-000-TU | 878 |
|
Buy Now | |||||||
|
MLX90614ESF-DCA-000-TU | 199 | 12 Weeks | 55 |
|
Buy Now | |||||
|
MLX90614ESF-DCA-000-TU | 17,832 |
|
Get Quote | |||||||
Melexis Microelectronic Integrated Systems MLX90614ESF-BAA-000-TUTemp Sensor Digital Serial (2-Wire, SMbus) 4-Pin TO-39 Can |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
MLX90614ESF-BAA-000-TU | 54 | 54 |
|
Buy Now | ||||||
|
MLX90614ESF-BAA-000-TU | 1,171 |
|
Buy Now | |||||||
|
MLX90614ESF-BAA-000-TU | 54 | 12 Weeks | 55 |
|
Buy Now | |||||
|
MLX90614ESF-BAA-000-TU | 72 |
|
Buy Now | |||||||
| MLX90614ESF-BAA-000-TU | 41 |
|
Buy Now | ||||||||
| MLX90614ESF-BAA-000-TU | 7 |
|
Buy Now | ||||||||
|
MLX90614ESF-BAA-000-TU | 50 |
|
Buy Now | |||||||
|
MLX90614ESF-BAA-000-TU | 6,000 |
|
Buy Now | |||||||
Documents mentioning MLX9061
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| mlx90616 | MLX90616ESF-HCA Infra Red Thermometer in TO-39 for high temperature thermometer guns Features and Benefits Applications Examples Easy to integrate Factory calibrated in wide temperature range -40…+85 ˚C for sensor temperature Measurement range -70°C to 1030°C |
Original | ||||
| mlx90614 | Application Note Analog voltage output with MLX90614 Application Note Analog voltage output with MLX90614 Scope Analog output voltage is sometimes needed from sensors in a system. Current application note describes how to implement that with the MLX90614 IR thermometer. |
Original | ||||
| mlx90614 | MLX90614 family Single and Dual Zone Infra Red Thermometer in TO-39 Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…+125 ˚C for sensor temperature and -70…+380 ˚C for object temperature. |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…85˚C for sensor temperature and -40…115˚C for object temperature High accuracy of 0.5°C over wide temperature |
Original | ||||
| mlx90614 | MLX90614 Changing emissivity How to … (example included) 1 Scope The MLX90614 sensors have a build in emissivity compensation function which allows the customer to change the emissivity coefficient without the need of recalibration. The aim of this document is to describe |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…85˚C for sensor temperature and -40…115˚C for object temperature High accuracy of 0.5°C over wide temperature |
Original | ||||
| ir thermometer | Comparison IR thermometers MLX90614 / MLX90615 Introduction The MLX90614 family and the MLX90615 infrared thermometers have very comparable characteristics. However, there are some differences one has to be mindful of when comparing them. This is a list of the most important difference. |
Original | ||||
| mlx90614 | Application Note Understanding MLX90614 on-chip digital signal filters Scope The MLX90614 is an easy-to integrate IR thermometer in TO39 package. It uses a two chip architecture to provide a fully integrated and calibrated solution. The sensor die is a CMOS |
Original | ||||
| mlx90614 | Application Note MLX90614 Grounding and layout Scope Virtually any electronic device needs proper layout, grounding and power supply bypassing. The MLX90614 IR thermometers have simple requirements in this aspect. These are described in the following document. |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…85˚C for sensor temperature and -40…115˚C for object temperature High accuracy of 0.5°C over wide temperature |
Original | ||||
| MLX90614 family Single and Dual Zone Infra Red | MLX90614 family Single and Dual Zone Infra Red Thermometer in TO-39 Features and Benefits Applications Examples High precision non-contact temperature measurements Thermal Comfort sensor for Mobile Air Conditioning control system Temperature sensing element for residential, |
Original | ||||
| mlx90614 | USER MANUAL MLX90614 Evaluation board MLX90614 Single and Dual zone Infra Red thermometer Evaluation Board EVB90614 User Manual 390129061401 Rev 004 Page 1 of 23 User Manual Jan/2008 USER MANUAL MLX90614 Evaluation board Table of Contents 1 Introduction… 3 |
Original | ||||
| mlx90614 | Design Example Thermostat with MLX90614 Scope This design example describes an example of a thermostat with a MLX90614 without using a microcontroller. Temperature control is non-contact thanks to the factory calibrated IR thermometer MLX90614. Applications |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40 to 85 ˚C for sensor temperature and -40 to 115 ˚C for object temperature. High accuracy of 0.5°C over wide temperature |
Original | ||||
|
|
||||||
| mlx9 | MLX90614 family Single and Dual Zone Infra Red Thermometer in TO-39 Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40 to 125 ˚C for sensor temperature and -70 to 380 ˚C for object temperature. |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…85˚C for sensor temperature and -40…115˚C for object temperature High accuracy of 0.5°C over wide temperature |
Original | ||||
| mlx90 | MLX90616ESF-HCA Infra Red Thermometer in TO-39 for high temperature thermometer guns Features and Benefits Applications Examples Easy to integrate Factory calibrated in wide temperature range -40…+85 ˚C for sensor temperature Measurement range -70°C to 1030°C |
Original | ||||
| mlx90614 | Application Note SMBus communication with MLX90614 1 Scope This document introduces the users in SMBus communication protocol and especially how it can be used to communicate with MLX90614 infrared thermometers. The MLX90614 is an Infra Red thermometer for non contact temperature measurements. Both the IR sensitive thermopile |
Original | ||||
| mlx90615 | MLX90615 Infra Red Thermometer Features and Benefits Applications Examples High precision non-contact temperature measurements; Hand-held thermometers Ear thermometers Home appliances with temperature control; Healthcare; Livestock monitoring; Multiple zone temperature control – up to 100 |
Original | ||||
| mlx90614 | Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267 MLX90614 Infrared Thermometer Modules 90° Field of View Thermopile (#28040) |
Original | ||||
| mlx9061 | Bus ICs Product Information MLX90614 BLDC Motor Control ICs Digital, Plug and Play, Infrared Thermometer in a TO Can The MLX90614 infrared thermometer is the solution for cheap and reliable contact-less temperature measurements. The integration of an infrared sensor and dedicated signal processing |
Original | ||||
| mlx906 | MLX90614 family Single and Dual Zone Infra Red Thermometer in TO-39 Features and Benefits Applications Examples Small size, low cost Easy to integrate Factory calibrated in wide temperature range: -40…+125 ˚C for sensor temperature and -70…+380 ˚C for object temperature. |
Original | ||||