Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MK SWITCH AND SOCKETS Search Results

    MK SWITCH AND SOCKETS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CN-DSUB15SKT0-000
    Amphenol Cables on Demand Amphenol CN-DSUB15SKT0-000 D-Subminiature (DB15 Female D-Sub) Connector, 15-Position Socket Contacts, Solder-Cup Terminals PDF
    CN-DSUBHD15SK-000
    Amphenol Cables on Demand Amphenol CN-DSUBHD15SK-000 High-Density D-Subminiature (HD15 Female D-Sub) Connector, 15-Position Socket Contacts, Solder-Cup Terminals PDF
    CN-DSUB37SKT0-000
    Amphenol Cables on Demand Amphenol CN-DSUB37SKT0-000 D-Subminiature (DB37 Female D-Sub) Connector, 37-Position Socket Contacts, Solder-Cup Terminals PDF
    CN-DSUBHD44SK-000
    Amphenol Cables on Demand Amphenol CN-DSUBHD44SK-000 High-Density D-Subminiature (HD44 Female D-Sub) Connector, 44-Position Socket Contacts, Solder-Cup Terminals PDF
    CN-DSUB25SKT0-000
    Amphenol Cables on Demand Amphenol CN-DSUB25SKT0-000 D-Subminiature (DB25 Female D-Sub) Connector, 25-Position Socket Contacts, Solder-Cup Terminals PDF

    MK SWITCH AND SOCKETS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: New Product Power Relays MK-S X MK-S-series Relays with DC-switching Models That Can Switch 220 VDC, 10 A (Resistive Load). • Switch a DC load of 220 VDC, 10 A (resistive load). • Models for AC Loads can switch 250 VAC, 15 A (resistive load). • Lineup includes models with SPST-NO and SPST-NO/SPSTNC contact forms.


    Original
    6835-3011/Fax: 21-5037-2222/Fax: 2356-81-300/Fax: J175-E1-02 PDF

    ARINC 552

    Abstract: Leach Relay bacr13ce2 ARINC 743a arinc 600 6 mcu tray BACR13CE2 arinc 600 8 mcu tray TSO-C117a Honeywell Document 060-4267-000 mounting tray ARINC ARINC 708
    Contextual Info: AlliedSignal, Inc. MK V Enhanced Ground Proximity Warning System Installation Design Guide Part Numbers 965-0976-0xx-xxx-xxx This document is an unpublished work. Copyright 1999 AlliedSignal Inc. All rights reserved. This document and all information and expression contained herein are the property of


    Original
    965-0976-0xx-xxx-xxx SASB767eC ARINC 552 Leach Relay bacr13ce2 ARINC 743a arinc 600 6 mcu tray BACR13CE2 arinc 600 8 mcu tray TSO-C117a Honeywell Document 060-4267-000 mounting tray ARINC ARINC 708 PDF

    ELCB 3 phase CONNECTION DIAGRAM

    Abstract: DZ158-1-125A 3 pole 25KA 100A NB310L ELCB CONNECTION DIAGRAM 400 NDK 23 MRJ4M-LS02 dz158 isolators 415v 4 pole Low Voltage Isolator Switch
    Contextual Info: ILLUSTRATED CATALOGUE VALID FROM MARCH 2014 CIRCUIT PROTECTION EQUIPMENT MOTOR CONTROL GEAR COMPONENTS POWER PROTECTION DEVICES Inverter n ACB n Solar Panel n Resin Core Transformer n Oil Filled Transformer For further information on each of these products


    Original
    26ments PLBR03 ELCB 3 phase CONNECTION DIAGRAM DZ158-1-125A 3 pole 25KA 100A NB310L ELCB CONNECTION DIAGRAM 400 NDK 23 MRJ4M-LS02 dz158 isolators 415v 4 pole Low Voltage Isolator Switch PDF

    cx-1050-sd

    Abstract: rj11 plug wiring diagram to bnc Emerson Cuming Stycast 1365 datacard Silicon Diode DT-470 cable pinout for m340 T.G. biddle Emerson Cuming Stycast 2850 Lake Shore Cryotronics silicon diode temperature sensor
    Contextual Info: User’s Manual Model 340 Temperature Controller Auto Tune 340 Temperature Controller Zone Settings P I Heater Range Control Channel Heater Off Setpoint Ramp Program Input Setup SoftCal D Control Setup Scan Setup Curve Entry Loop 1 Alarm Setup Math Setup Loop 2


    Original
    lakeshore297 cx-1050-sd rj11 plug wiring diagram to bnc Emerson Cuming Stycast 1365 datacard Silicon Diode DT-470 cable pinout for m340 T.G. biddle Emerson Cuming Stycast 2850 Lake Shore Cryotronics silicon diode temperature sensor PDF

    CHN 550

    Abstract: CHN 545 chn 710 CHN 712 chn 538 CHN 431 CHN 709 CHN 741 chn 738 chn 648 equivalent
    Contextual Info: R&S ZNC/ZND Vector Network Analyzers User Manual ;xíÇ2 User Manual Test & Measurement 1173.9557.02 ─ 26 This manual describes the following vector network analyzer types: ● R&S®ZNC3 (2 ports, 9 kHz to 3 GHz, N connectors), order no. 1311.6004K12


    Original
    6004K12 ZNC-B10 ZN-B14 ZNC-B19 ZNC3-B22 ZNC-K19 VXI-11 CHN 550 CHN 545 chn 710 CHN 712 chn 538 CHN 431 CHN 709 CHN 741 chn 738 chn 648 equivalent PDF

    SOCKET HEAD CAP SCREWS DIMENSION DIAGRAM

    Abstract: A22E A22Z-B101Y A22Z-B10 A22-12 A22EL-M-24A-11 A22L-01M-T2 a22l BA9S spst Pushbutton
    Contextual Info: Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-51, Æ . only for NC contacts • Safety lock mechanism prevents misuse. (No tampering – in accordance with EN 418)


    Original
    22-dia. 25-dia. EN60947-51, A22Z-3466-1 A22Z-B101Y D-216 D-232 SOCKET HEAD CAP SCREWS DIMENSION DIAGRAM A22E A22Z-B101Y A22Z-B10 A22-12 A22EL-M-24A-11 A22L-01M-T2 a22l BA9S spst Pushbutton PDF

    A22E

    Abstract: g307 G306 EN60947-5-1 A22Z-B10
    Contextual Info: Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Æ . only for NC contacts • Safety lock mechanism prevents misuse. (No tampering – in accordance with EN 418)


    Original
    22-dia. 25-dia. EN60947-5-1, A22Z-3466-1 A22Z-B101Y G-303 G-319 A119-E2-03A-X G-320 A22E g307 G306 EN60947-5-1 A22Z-B10 PDF

    2CSC400002D0208

    Abstract: 12v 200 ohm 1c/o relay MTME-485-SUI-LCD-96 ABB RD2 earth leakage relay ANR96 ANR96-230 LEONE RELAY 12V 20A 5v 100 ohm 1c/o relay ABB anr96 MTME-485-LCD-96
    Contextual Info: In consideration of modifications to Standards and materials, the characteristics and overall dimensions indicated in this catalogue may be considered binding only following confirmation by ABB Copyright 2010 ABB. All right reserved. System pro M compact and other modular devices for low voltage installation


    Original
    2CSC400002D0208 12v 200 ohm 1c/o relay MTME-485-SUI-LCD-96 ABB RD2 earth leakage relay ANR96 ANR96-230 LEONE RELAY 12V 20A 5v 100 ohm 1c/o relay ABB anr96 MTME-485-LCD-96 PDF

    VG 95238 itt cannon

    Abstract: ITT Cannon Connectors itt zd DIN72585 itt cannon XLR whisker ITT connector MS5015 XLR connector combo xlr socket whisker ITT
    Contextual Info: Datasheet Page 1 of 2 Home > Search Tools > ITT Part Number ITT Part Number Search Enter Part Number: Go PART NUMBER:MS3122E1210S Shell Style Box mounting receptacle Gender Socket Shell Size 12 Contact Arrangement 1210 Number of contacts 10 contacts size 20


    Original
    MS3122E1210S AWG20 VG95319 VG 95238 itt cannon ITT Cannon Connectors itt zd DIN72585 itt cannon XLR whisker ITT connector MS5015 XLR connector combo xlr socket whisker ITT PDF

    AT88CK109STK3 User Guide

    Abstract: SMD w35 Transistor Atmel STK600 schematic SMT-0540-S-R smd diode w25 at88sa102 C0603Y5V250-105ZNE 499-P36-20 AT88SA100 BR1111C-TR
    Contextual Info: AT88CK109STK3 Hardware User Guide 8557B—CRYPTO—04/09 Table of Contents Section 1 Introduction. 1-1 1.1 Overview. 1-1


    Original
    AT88CK109STK3 8557B--CRYPTO--04/09 AT88CK109STK3 699A--CRYPTO--10/09 AT88CK109STK3 User Guide SMD w35 Transistor Atmel STK600 schematic SMT-0540-S-R smd diode w25 at88sa102 C0603Y5V250-105ZNE 499-P36-20 AT88SA100 BR1111C-TR PDF

    cambasic

    Abstract: BEST BIOS PROGRAMMING AND DATA FOR EEPROM octagon Octagon Systems 386SX manual LED 6030 nec floppy circuit 16C550 386SX IEC1000
    Contextual Info: PC MICROCONTROLLERS TABLE OF CONTENTS INTRODUCTION TO THE 6000 SERIES .3–2 60X0 COMMON FEATURES .3–3 60X0 I/O COMPARISON CHART .3–3


    Original
    PDF

    Melcher LT 1740

    Abstract: 1601-7R 1000 watt ups transformer diagram MELCHER PSR 248 1001-7R 1301-7R transformer dash 2 b-5 step down transformer 12-0-12 LT 1740 2660-7R
    Contextual Info: AC-DC Converters >100 W 11 AC-DC Converters >100 W 11.1 Rugged Environment Output [W] 150 300 500 1000 3000 3 Output [V DC] 5 12 15 24 36 48 Input [V AC] 85 110 135 170 220 265 Product Family Case Page K K02 11 - 2 T T01 11 - 25 VSR various 11 - 55 Product


    Original
    PDF

    Contextual Info: R Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout H Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, → H Safety Lock Mechanism prevents misuse. No tamper – in accordance with EN418


    Original
    22-dia. 25-dia. EN60947-5-1, EN418) UL508, E41515 EN60947-5-1 30ing 1-800-55-OMRON PDF

    FMCW

    Contextual Info: m o c . o c l e v i n . w w 2012/2 w PRODUCT CATALOGUE PRODUCT CATALOGUE 2012/2 SUBSIDIARY AND DISTRIBUTION NETWORK To find a local NIVELCO representation, please check distribution page on NIVELCO website! CONTACT NIVELCO To contact NIVELCO, please use contact page on NIVELCO website!


    Original
    H-1043 NIVIS01 nikat11a0604d FMCW PDF

    TRANSISTOR k2185

    Contextual Info: Model 540 Voltsensor CALEX MANUFACTURING CO SEE 2401 Stanwell Drive, Concord, CA 94520-4841 D 1011250 000105b 510 687-4411 (800)542-3355 37b « C E X FAX: (510) 687-3333 FEATURES • Rugged reliable solid state replacement for meter relays. • Uses almost any power source from +5 to +32V D C


    OCR Scan
    000105b 26VDC, 10msec 00ELS or28V TRANSISTOR k2185 PDF

    IS63LV1024-J

    Abstract: CY7C1018BV33-V IDT71V124SA-TY K6R1008 Programmer stk500 9 pin rs232 cable STK500 STK503 isp CONNECTOR AS7C31025A-HFC
    Contextual Info: Table of Contents TABLE OF CONTENTS . 1 STK503 USER GUIDE . 2 INTRODUCTION . 2


    Original
    STK503 CY7C1019BV33-V 300-mil 400-mil IS63LV1024-J CY7C1018BV33-V IDT71V124SA-TY K6R1008 Programmer stk500 9 pin rs232 cable STK500 isp CONNECTOR AS7C31025A-HFC PDF

    2615A

    Abstract: 36pa
    Contextual Info: INSTRUCTION MANUAL SPECTRUM ANALYZERS MODELS 2165A 2620A 2625 2630 TEST INSTRUMENT SAFETY Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed voltage is present. An electrical shock causing 10 milliamps of


    Original
    v110409 2615A 36pa PDF

    Contextual Info: Emergency Stop Switch 22-dia./25-dia. A22E CSM_A22E_DS_E_11_1 Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism to open the circuit when the contact welds → . • Safety lock mechanism prevents operating errors. • Easy mounting and removal of Switch Blocks using a lever.


    Original
    22-dia /25-dia. 22-dia. 25-dia. /IP65 PDF

    Transistor k163

    Abstract: capacitor 100N k100 K163 TRANSISTOR 16F84 frequency meter ic 12f675 project pic 16f84 LED Flashing touch sensitive siren using transistor sound sensor alarm NE555 18f252 Siren Sound Generator 5 sound with pic 12f675
    Contextual Info: K149 USB PICmicro Programmer DIY Electronics HK Ltd PO Box 88458, Sham Shui Po, Hong Kong http://www.kitsrus.com mailto: peter@kitsrus.com Last Modified March 3 2003 Board Construction The board is quite easy to construct and it is advisable to read through these


    Original
    10-relay, Transistor k163 capacitor 100N k100 K163 TRANSISTOR 16F84 frequency meter ic 12f675 project pic 16f84 LED Flashing touch sensitive siren using transistor sound sensor alarm NE555 18f252 Siren Sound Generator 5 sound with pic 12f675 PDF

    OMRON E5CN

    Abstract: omron zen 10c1dr-d-v1 Omron SPEED sensor 12v m16 OMRON H5CX programming manual omron zen 10c1ar-a-v1 omron TS 101 DA analogue extension modules ZEN 10C1DR-D-V1 sv 120 230 liquids dual level relay manual omron e5cs Omron H7CR Catalog
    Contextual Info: INDUSTRIAL COMPONENTS Product Selector 2004 / 2005 • Electromechanical relays • Timers • Counters • Programmable relays • Level and leakage controllers • Industrial switches • Pushbutton switches • Low voltage switch gear • Temperature controllers


    Original
    PDF

    a22t

    Abstract: A22E-M-12-EMO A22E-M-11-EMO A22E A22E-MP A22Z-3360 A22E-M-12-EMS A22Z-346 a2232 A22E-S12
    Contextual Info: Emergency Stop Switch 22-dia./25-dia. A22E CSM_A22E_DS_E_8_1 Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism to open the circuit when the contact welds → . • Safety lock mechanism prevents operating errors. • Easy mounting and removal of Switch Blocks using a lever.


    Original
    22-dia /25-dia. 22-dia. 25-dia. /IP65 omron247 a22t A22E-M-12-EMO A22E-M-11-EMO A22E A22E-MP A22Z-3360 A22E-M-12-EMS A22Z-346 a2232 A22E-S12 PDF

    6A01 diode

    Abstract: A22 SMD CODE smd 6a01 A22-12 A22E A22E-SK-11 diode 6a11 touch panel noise reduction emergency light introduction pushbutton A22
    Contextual Info: Emergency Stop Switch 22-dia./25-dia. A22E Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism to open the circuit when the contact welds → . ■ Safety lock mechanism prevents operating errors. ■ Easy mounting and removal of Switch Blocks using a lever.


    Original
    22-dia /25-dia. 22-dia. 25-dia. /IP65 6A01 diode A22 SMD CODE smd 6a01 A22-12 A22E A22E-SK-11 diode 6a11 touch panel noise reduction emergency light introduction pushbutton A22 PDF

    12M250

    Abstract: ABB inverter motor fault code ptc s1450 MC4046 REC310PE72 10 amp 12 volt solar charger circuits SOLAR INVERTER 1000 watts circuit diagram
    Contextual Info: Contents System Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Grid-Tie Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


    Original
    PDF

    Q2520I-80P

    Abstract: Q2520I-80N qualcomm 75 Q2520I80N AN2334 Q2520 AN2334-4
    Contextual Info: X P to 1993 02510/ Q2520 DIGfTAL-TO-ANALOG CONVERTERS J wl ' Q ualocw w a Products CONTENTS FIGURES FEATURES. 3 Q2510 F eatures.3 1. Q2510 Functional Block D iagram . 4 2. Q2520 Functional Block D iagram . 4


    OCR Scan
    Q2520 Q2510 Q2520 Q2520I-80P Q2520I-80N qualcomm 75 Q2520I80N AN2334 AN2334-4 PDF