MIL-STD-202 METHOD 302 Search Results
MIL-STD-202 METHOD 302 Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
DE6B3KJ101KA4BE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive | |||
DE6B3KJ331KB4BE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive | |||
DE6E3KJ102MN4A | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive | |||
DE6E3KJ472MA4B | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive | |||
DE6B3KJ331KA4BE01J | Murata Manufacturing Co Ltd | Safety Standard Certified Lead Type Disc Ceramic Capacitors for Automotive |
MIL-STD-202 METHOD 302 Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
mil-std-202
Abstract: mil-std-202 101D 101D 106F "MIL-STD-202" "METHOD 302" "CONDITION B"
|
Original |
IP16/IP18 IP66/IP68 mil-std-202 mil-std-202 101D 101D 106F "MIL-STD-202" "METHOD 302" "CONDITION B" | |
Contextual Info: Surface Mount Fuses Subminiature Surface Mount PICO SMF 459 and 460 Series Fuses ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: –55°C to 125°C. Shock: MIL-STD-202, Method 213, Test Condition I 100 G’s peak for 6 milliseconds . Vibration: MIL-STD-202, Method 201 (10–55 Hz, .06 in. total excursion). |
Original |
MIL-STD-202, 10x1000 10x160 10x560 | |
Contextual Info: Surface Mount Fuses Subminiature Surface Mount PICO SMF 459 and 460 Series Fuses ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: –55°C to 125°C. Shock: MIL-STD-202, Method 213, Test Condition I 100 G’s peak for 6 milliseconds . Vibration: MIL-STD-202, Method 201 (10–55 Hz, .06 in. total excursion). |
Original |
MIL-STD-202, | |
Contextual Info: Surface Mount Fuses Subminiature Surface Mount PICO SMF 459 and 460 Series Fuses ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: –55°C to 125°C. Shock: MIL-STD-202, Method 213, Test Condition I 100 G’s peak for 6 milliseconds . Vibration: MIL-STD-202, Method 201 (10–55 Hz, .06 in. total excursion). |
Original |
MIL-STD-202, | |
Contextual Info: Littelfuse Surface Mount Fuses Subminiature Surface Mount PICO SMF 459 and 460 Series Fuses ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: -55°C to 125°C. Shock: MIL-STD-202, Method 213, Test Condition I 100 G’s peak for 6 milliseconds . Vibration: MIL-STD-202, Method 201 (10-55 Hz, .06 in. total excursion). |
OCR Scan |
MIL-STD-202, | |
MIL-C-83446
Abstract: MILC83446 mil-std-202 MIL-STD-883 method 2011 MIL-STD-883, METHOD 2011 delevan
|
OCR Scan |
MIL-C-83446, MIL-C-15305, MIL-STD-202 MIL-C-83446 MIL-STD-202. MIL-STD-202, MIL-STD-883, MILC83446 MIL-STD-883 method 2011 MIL-STD-883, METHOD 2011 delevan | |
MIL-PRF-83446
Abstract: 4221-2 1008HF mil-std-202 method 108 RC-1009B S1008 S1210 INDUCTOR DIP Mil-std 0603X
|
Original |
MIL-PRF-83446, MIL-PRF-15305, MIL-STD-202 1206-XXX 1266-XXX 1210-XXX 1806-XXX 1812-XXX PD105 PD104 MIL-PRF-83446 4221-2 1008HF mil-std-202 method 108 RC-1009B S1008 S1210 INDUCTOR DIP Mil-std 0603X | |
Contextual Info: TECHNICAL NOTES Surface Mount Inductors TESTING: MIL-PRF-83446, MIL-PRF-15305, and MIL-STD-202 are used as guidelines for type of test, method, and requirement. These specifications are employed as reference guidelines and may be adjusted, based on design, application, or market need. Consult the |
OCR Scan |
MIL-PRF-83446, MIL-PRF-15305, MIL-STD-202 ISO9001 1266-XXX 1210-XXX 1806-XXX 1812-XXX PD104 PD105 | |
Contextual Info: TECHNICAL NOTES Surface Mount Inductors TESTING: MIL-PRF-83446, MIL-PRF-15305, and MIL-STD-202 are used as guidelines for type of test, method, and requirement. These specifications are employed as reference guidelines and may be adjusted, based on design, application, or market need. Consult the |
Original |
MIL-PRF-83446, MIL-PRF-15305, MIL-STD-202 MIL-STD-174. | |
Contextual Info: Technical Notes Surface Mount Inductors TESTING: MIL-PRF-83446, MIL-PRF-15305, and MIL-STD-202 are used as guidelines for type of test, method, and requirement. These specifications are employed as reference guidelines and may be adjusted, based on design, application, or market need. Consult the |
Original |
MIL-PRF-83446, MIL-PRF-15305, MIL-STD-202 MILSTD-174. | |
RWR89SR
Abstract: rw marking code WR81N R80z 81W MARKING CODE t+2a/IL-R-39007
|
OCR Scan |
MIL-R-39007 MIL-STD-202, S-1-80 RWR89SR rw marking code WR81N R80z 81W MARKING CODE t+2a/IL-R-39007 | |
MIL-R-39007* rwr81s
Abstract: RWR81 RWR81S 39-200 MIL-R-39007 EGN-1-10 EGN-1-80 EGN-2-10 EGN-3-10 EGN-3-80
|
Original |
MIL-R-39007 MIL-STD-202, MIL-R-39007 EGS-1-80 RWR81S EGN-1-80 RWR81W RWR81N EGN-1-10 RWR81Z MIL-R-39007* rwr81s RWR81 RWR81S 39-200 EGN-1-10 EGN-1-80 EGN-2-10 EGN-3-10 EGN-3-80 | |
Contextual Info: ESTABLISHED RELIABILITY M Ifs WIREWOUND RESISTORS MIL-R-39007, TYPE RWR, R LEVEL DALE TYPE ESS, ESW, EGS, Silicone Coated and Molded “S ” Level Failure Rate Available FEATURES • Meets solvent resistance of MIL-STD-202, Method 215. • Traceability of materials and processing. |
OCR Scan |
MIL-R-39007, MIL-STD-202, MiL-R-39007 S-1-80' | |
Contextual Info: MODELS ESS/W/N, EGS/W/N Wirewound Resistors Military/Established Reliability MIL-R-39007 Qualified, Type RWR, R Level FEATURES • Meets solvent resistance of MIL-STD-202, Method 215 • 100% power stabilization and screening test • Traceability of materials and processing |
OCR Scan |
MIL-R-39007 MIL-STD-202, MIL-R-39007 EGS-1-80 EGN-1-80 EGN-1-10 EGN-2-10 EGS-3-80 EGN-3-80 EGN-3-10 | |
|
|||
bq 738
Abstract: IRF 1470 pj 989 IRF 460 Application 0/bq 738
|
Original |
2002/95/EC MIL-STD-202, MIL-PRF-15305 09-Feb-09 bq 738 IRF 1470 pj 989 IRF 460 Application 0/bq 738 | |
Contextual Info: IMS-5 Vishay Dale Inductors, Commercial, Molded, Shielded, Axial Leaded FEATURES ELECTRICAL SPECIFICATIONS Inductance Tolerance: ± 10 % standard, ± 5 % available Insulation Resistance: 1000 MΩ minimum per MIL-STD-202, method 302, test condition B Dielectric Withstanding Voltage: 1000 VAC per |
Original |
2002/95/EC MIL-STD-202, MIL-PRF-15305 2011/65/EU 2002/95/EC. 2002/95/EC 2011/65/EU. 12-Mar-12 | |
Contextual Info: IMS-5 Vishay Dale Inductors, Commercial, Molded, Shielded, Axial Leaded FEATURES ELECTRICAL SPECIFICATIONS Inductance Tolerance: ± 10 % standard, ± 5 % available Insulation Resistance: 1000 MΩ minimum per MIL-STD-202, method 302, test condition B Dielectric Withstanding Voltage: 1000 VAC per |
Original |
MIL-STD-202, MIL-PRF-15305 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12 | |
Contextual Info: IMS-5 Vishay Dale Inductors, Commercial, Molded, Shielded, Axial Leaded FEATURES ELECTRICAL SPECIFICATIONS Inductance Tolerance: ± 10 % standard, ± 5 % available Insulation Resistance: 1000 MΩ minimum per MIL-STD-202, method 302, test condition B Dielectric Withstanding Voltage: 1000 VAC per |
Original |
2002/95/EC MIL-STD-202, MIL-PRF-15305 18-Jul-08 | |
Contextual Info: IMS-5 Vishay Dale Inductors, Commercial, Molded, Shielded, Axial Leaded FEATURES ELECTRICAL SPECIFICATIONS Inductance Tolerance: ± 10 % standard, ± 5 % available Insulation Resistance: 1000 MΩ minimum per MIL-STD-202, method 302, test condition B Dielectric Withstanding Voltage: 1000 VAC per |
Original |
MIL-STD-202, MIL-PRF-15305 11-Mar-11 | |
marking z5e capacitorContextual Info: TUSONIX 1.0 1.1 1.2 1.3 GENERAL SPECIFICATIONS MECHANICAL Case: Conformal coated. Lead Material: Copper clad steel. Terminal Strength: Mil-Std-202, Method 211, Condition A radial . 2 lbs. TUSONIX style 8121 and smaller. 5 lbs. TUSONIX style 8131 and larger. |
OCR Scan |
Mil-Std-202, N4700 N5600 marking z5e capacitor | |
Contextual Info: X7R Dielectric “C” GENERAL SPECIFICATIONS Capacitance Range See Individual Parts Specifications Insulation Resistance 25°C MIL-STD-202-Method 302 100 K megohms or 1000 megohms - µF minimum, whichever is less Capacitance Test at 25°C Measured at 1 VRMS max. at 1 KHz |
Original |
MIL-STD-202-Method | |
Contextual Info: X7R Dielectric “C” GENERAL SPECIFICATIONS Capacitance Range See Individual Parts Specifications Insulation Resistance 25°C MIL-STD-202-Method 302 100 K megohms or 1000 megohms - µF minimum, whichever is less Capacitance Test at 25°C Measured at 1 VRMS max. at 1 KHz |
Original |
MIL-STD-202-Method MIL-ST202-Method | |
Contextual Info: Z5U Dielectric “E” GENERAL SPECIFICATIONS Capacitance Range See Individual Parts Specifications Insulation Resistance 25°C MIL-STD-202-Method 302 10 K megohms or 100 megohms - µF minimum, whichever is less Capacitance Test at 25°C Measured at 0.5 VRMS max. at 1 KHz |
Original |
MIL-STD-202-Method | |
Contextual Info: Z5U Dielectric “E” GENERAL SPECIFICATIONS Capacitance Range See Individual Parts Specifications Insulation Resistance 25°C MIL-STD-202-Method 302 10 K megohms or 100 megohms - µF minimum, whichever is less Capacitance Test at 25°C Measured at 0.5 VRMS max. at 1 KHz |
Original |
MIL-STD-202-Method |