2009 - QQ-S365
Abstract: TEFLON MIL-P-19468 MIL-P-19468 mil-std-202 mil-std-202 METHOD 106 QQC-530 QQ-B-626
Text: 253/124 [2.8/1.4] 500 25 [2.8] -55 to +85 -65 to +165 MIL-STD-202 Method 201A -65 to +1651 -55 to +852 MIL-STD-202 MIL-STD-202 Method 204 Method 204 Cond. B Cond. B MIL-STD-202 MIL-STD-202 Method 213 Method 213 Cond. G, 50 Gâs Cond. G, 50 Gâs -65 to +85 â -65 to +165 -65 to +165 -55 to +85 -55 to +85 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-1344 Method
|
Original
|
PDF
|
ohm/75
P-24519.
QQ-S365
TEFLON MIL-P-19468
MIL-P-19468
mil-std-202
mil-std-202 METHOD 106
QQC-530
QQ-B-626
|
2002 - L44PCW
Abstract: MIL-STD-202 METHOD 101 MIL-STD-202 METHOD 213 Andrew L44PCW connector mil-std-202, method 107 27591-109 LDF4RN-50A-S3 mil-std-202 METHOD 106 mil-std-202, method 204,cONDITION A mil-std-202, method 204
Text: Operating Temperature Range, °C Storage Temperature Range, °C MIL-STD-202 , Method 106 MIL-STD-202 , Method 213, Condition I MIL-STD-202 , Method 101, Condition B MIL-STD-202 , Method 107, Cond A-1, Low Temp -55°C MIL-STD-202 , Method 204, Condition B -55 to 150 -70 to 150 0.05 frequency(GHz) Solder on Self , Operating Temperature Range, °C Storage Temperature Range, °C MIL-STD-202 , Method 106 MIL-STD-202 , Method 213, Condition I MIL-STD-202 , Method 101, Condition B MIL-STD-202 , Method 107, Cond A-1, Low Temp
|
Original
|
PDF
|
L44PCW
LDF4-50A,
MIL-STD-202,
L44PCW
MIL-STD-202 METHOD 101
MIL-STD-202 METHOD 213
Andrew L44PCW connector
mil-std-202, method 107
27591-109
LDF4RN-50A-S3
mil-std-202 METHOD 106
mil-std-202, method 204,cONDITION A
mil-std-202, method 204
|
mil-std-202, method 107
Abstract: qq-c-576
Text: [2.8] 6/6 [26.7/26.7] 60 [2669] 601266.9] RG58C/U 500 25 [2.8] -65 to+85 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G (50 G , âs) MIL-STD-202 Method 107 -65 to +165' -55 to +852 MIL-STD-202 Method 204 Cond B MIL-STD-202 Method 213 Cond. I, (100 Gâs) MIL-STD-202 Method 107 Cond. B MIL-STD-202 Method 106 MIL-STD-202 Method 101 Cond. B 108-12001 , [266.9] 500 25 [2.8] 2 [.023] 100 [4448] 40 [178 0] 500 25 [2.8] -65 to +165 MIL-STD-202
|
OCR Scan
|
PDF
|
Q-N-290
QQ-N-290
MIL-G-45204
MIL-P-24519.
mil-std-202, method 107
qq-c-576
|
2011 - 2455R
Abstract: 2455RM 2455RVB MIL-STD-202 METHOD 302 MIL-STD-202 METHOD 301 2450RC mil-std-202 method 112 2450CM 2450H MIL-PRF-24236
Text: strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case Insulation resistance MIL-STD-202 , Method 302; 50 MOhm min. Terminal to Case Contact resistance MIL-STD-202 , Method 307; 0.050 Ohm Hermetic seal MIL-STD-202 , Method 112; Cond. A, 1x10-5 atm cc/s Moisture resistance MIL-STD-202 , ] Dielectric strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case
|
Original
|
PDF
|
009031-2-EN
2455R
2455RM
2455RVB
MIL-STD-202 METHOD 302
MIL-STD-202 METHOD 301
2450RC
mil-std-202 method 112
2450CM
2450H
MIL-PRF-24236
|
MIL-P-19468
Abstract: No abstract text available
Text: MIL-STD-202 Method 204 Cond B MIL-STD-202 Method 213 Cond G MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-1344 Method 2005 Cond. Ill MIL-STD-1344 Method 2004 Cond , -1344 Method 1001 Cond. B 108-12044 108-12047 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 , , Operating (C°) Vibration Physical Shock -65 to +165â -55 to +85" MIL-STD-202 MIL-STD-202 Method 204 Method 204 Cond.B Cond. B MIL-STD-202 MIL-STD-202 Method 213 Method 213 Cond. G, 50 G
|
OCR Scan
|
PDF
|
WIIL-C-39012
QQ-S-365
QQ-S-365
MIL-B-45204
MIL-G-45204
MIL-G-45204
QQ-N-290
MIL-P-19468
|
2008 - 2455R
Abstract: 2455rm 2455Rc 2455rbv 2450rc gold metal detectors 2455 Sealed Thermostat thermostat cap thermostats
Text: strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case Insulation resistance MIL-STD-202 , Method 302; 50 MOhm min. Terminal to Case Contact resistance MIL-STD-202 , Method 307; 0.050 Ohm Hermetic seal MIL-STD-202 , Method 112; Cond. A, 1x10-5 atm cc/s Moisture resistance MIL-STD-202 , ] Dielectric strength MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case MIL-STD-202 , Method 301; 1250 Vac 60 Hz - Terminal to Case
|
Original
|
PDF
|
009031-1-EN
2455R
2455rm
2455Rc
2455rbv
2450rc
gold metal detectors
2455
Sealed Thermostat
thermostat cap
thermostats
|
TR62P
Abstract: TR62Y502 TR62Y mil-r-22097 94v0 schematic TR06P103 mil-std-202 method 107d TR04G205 Potentiometers 25k TR03G102T
Text: 250ppm/_C on all other resistance values), MIL-STD-202 , method 304. INSULATION RESISTANCE: 100 megohms min. @ 500 V DC, MIL-STD-202 , method 302, condition B. DIELECTRIC STRENGTH: 500 V AC min., MIL-STD-202 , minutes each, 5 cycles MIL-STD-202 , method 107D, TRS ± 2% max., setting stability (voltage ratio) ± 1% max. MOISTURE RESISTANCE: Humidity cycle, MIL-STD-202 , method 106D, TRS ± 3% max. HUMIDITY: 40°C, 90 to 95% RH, MIL-STD-202 , method 103B, condition C, TRS ± 3% max., setting stability (voltage ratio
|
Original
|
PDF
|
TR03G500T
TR03J500T
TR03G101T
TR03G201T
TR03G501T
TR03G102T
TR03G202T
TR03G502T
TR03G103T
TR62P
TR62Y502
TR62Y
mil-r-22097
94v0 schematic
TR06P103
mil-std-202 method 107d
TR04G205
Potentiometers 25k
TR03G102T
|
MOX-750
Abstract: MOX400 Meg-90 MIL-R-49462A MEG40
Text: Power Conditioning Solderability Test Method MIL-STD-202 , Method 103B, Condition B MIL-STD-202 , Method 301, 750V MIL-STD-202 , Method 302, Condition A or B MIL-STD-202 , Method 107G, Condition B, B-1, or F MIL-STD-202 , Method 108A, Condition D MIL-STD-202 , Method 215G MIL-STD-202 , Method 211A, Condition A or B MIL-STD-202 , Method 213B, Condition I MIL-STD-202 , Method 204D, Condition D MIL-R-49462A, Par 4.8 MIL-STD-202 , Conditioning Solderability Test Method MIL-STD-202 , Method 103B, Condition B MIL-STD-202 , Method 301, 750V
|
Original
|
PDF
|
25K-6
Meg-100
Meg-200
Meg-300
Meg-400
Meg-500
MOX-750
MOX400
Meg-90
MIL-R-49462A
MEG40
|
EIA-198
Abstract: RPE MuRata RPE 113 EIA-198 method 103 EIA-RS-483 RPE-114 eia 198 RPE 114 x7r MIL-C-14409 RPE114
Text: not listed here. Barometric Pressure (Reduced): EIA-198 Method 207 or MIL-STD-202 Method 105 , (Dissipation Factor): EIA-198 Method 101 or MIL-STD-202 Method 305. Capable of MHz (10KHz to 10MHz) or KHz (100Hz to 100Khz). DWV (Dielectric Withstanding Voltage): EIA-198 Method 103 or MIL-STD-202 Method 301 , -198 Method 202 Cond. "B" or MIL-STD-202 Method 103, 40°C @ 90 to 95 % R.H. (with no voltage) test duration usually 504 hours. IR (Insulation Resistance): EIA-198 Method 104 or MIL-STD-202 Method 302. Resistance
|
Original
|
PDF
|
spa60g
MIL-PRF-55681
MIL-C-14409
CG01-I
EIA-198
MIL-STD-202
10KHz
10MHz)
100Hz
100Khz)
RPE MuRata
RPE 113
EIA-198 method 103
EIA-RS-483
RPE-114
eia 198
RPE 114 x7r
RPE114
|
2010 - Not Available
Abstract: No abstract text available
Text: Conditions Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202
|
Original
|
PDF
|
CCSO-914-1090
CCSO-914-1090
CCSO-014-1090
090GHz
-138dBc/Hz
10kHz
-40dBc
02-Feb-10
MIL-STD-202,
|
mil-std-202
Abstract: mil-std-202 method 213 method c 1090mhz oscillator SAW oscillator 1090
Text: Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III
|
Original
|
PDF
|
CCSO-014-1090
CCSO-014-1090
090GHz
-138dBc/Hz
10kHz
-35dBc
23-Feb-11
cry-STD-202,
MIL-STD-202,
mil-std-202
mil-std-202 method 213 method c
1090mhz oscillator
SAW oscillator 1090
|
MIL-R-39007
Abstract: Steatite Group lb 1260 49R9
Text: -watt size and larger. Solderability: Meets requirements of MIL-STD-202 Solvent resistance: Meets requirements of MIL-STD-202 MIL-R-39007: This is the military specification covering axial lead established , . resistance MIL-STD-202 , method 303 Within tolerance Visual & mechanical Visual inspection Temperature cycle Method 102, MIL-STD-202 .2% + .05 Short time overload 5 seconds at 10 or 5 times , Dielectric strength 500V or 1000V .1% + .05 Insulation Resistance Method 302, MIL-STD-202 1000
|
Original
|
PDF
|
MIL-R-39007
MIL-STD-202
MIL-R-39007:
MIL-R-39007
Steatite Group
lb 1260
49R9
|
MF-200
Abstract: Precision Resistive Products MIL-STD-202 METHOD 301 MF-100 MF-12 MF-25 MF-50 T100 TC25 TC50
Text: conditioning periods.) MIL-STD-202 Method 303 Within specified tolerance. As buyer requested ±25PPM/°C ±100PPM/°C ±50PPM/°C ±200PPM/°C DC RESISTANCE TEMPERATURE COEFFICIENT MIL-STD-202 Method 304 MIL-STD-202 Method 301 1/8W 300V 1 minute 1/4W 500V 1 minute 1/2W 700V 1 minute 1, 2W 750V 1 minute MIL-STD-202 Method 302 100V 1 minute DIELECTRIC STRENGTH No flashover or damage INSULATION , 0.05) RESISTANCE TO SOLVENT MIL-STD-202 Method 201 10~ Hz X.Y.Z. 3 directions 2 hours each
|
Original
|
PDF
|
100PPM/
MF-12
MF-25
MF-50
MF-100
MF-200
MIL-STD-202
MIL-R-10509
MF-200
Precision Resistive Products
MIL-STD-202 METHOD 301
MF-100
MF-12
MF-25
MF-50
T100
TC25
TC50
|
Not Available
Abstract: No abstract text available
Text: MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III, Condition
|
Original
|
PDF
|
CCSO-014-1090
CCSO-014-1090
10kHz
-35dBc
15-May-12
MIL-STD-202,
|
|
2010 - Not Available
Abstract: No abstract text available
Text: Conditions Mechanical Shock MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202
|
Original
|
PDF
|
CCSO-014-1090
CCSO-014-1090
090GHz
-138dBc/Hz
10kHz
-40dBc
18-Mar-10
MIL-STD-202,
|
29862
Abstract: 0434002 R451.750 0434003
Text: CSA. Approved by MITI from 1 through 5 amperes. Operating Temperature: 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition 1 (100 Gs peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (10-55 Hz, 0.06 in. total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Conditions B (48 hours). , .) Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Conditions F (20 sec. at 260°C). Thermal Shock: MIL-STC- 202 , Method 107, Test Condition B (65° to 125°C). Moisture Resistance: MIL-STD-202 , Method 106
|
Original
|
PDF
|
|
0451001.mrl
Abstract: 32vdc12a 001T 0451001mrl 0452500 0452001.MRL
Text: . Ambient Temperature: 55°C to +125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (10 55 Hz). Thermal Shock: MIL-STD-202 , . Solderability: MIL-STD-202 , Method 208. For iron soldering, Solder Iron Temp: 350° C 360° C, heating time 3 , : MIL-STD-202 , Method 213, Test Condition I Refer to pg. 374 for SMF Omni-Blok® Holder, Series 154 000 , milliseconds). Vibration: MIL-STD-202 , Method 201 (1055 Hz). Salt Spray: MIL-STD-202 , Method 101, Test
|
Original
|
PDF
|
|
1998 - R451.750
Abstract: No abstract text available
Text: /VDC (12A - 15A) ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: - 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (lo-55 Hz, .06 in. total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening) MIL-STD-202 , Method 302, Test Condition A, (10,000 ohms minimum). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (20 sec. at 260°C). Thermal Shock
|
Original
|
PDF
|
l/16-15
l/16-10
20seconds
E10480,
125VAC/VDC
125VACYVDC
65VAC/VDC
R452005
R451.750
|
1998 - R460.002
Abstract: No abstract text available
Text: SPECIFICATIONS: Operating Temperature: - 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (lo-55 Hz, .06 inches total excursion). Salt Spray: MIL-STD-202 , Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening) MIL-STD-202 , Method 302 (10,000 ohms minimum at 100 volts). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (10 sec. at 260°C). Thermal Shock: MIL-STD-202 , Method 107, Test Condition B
|
Original
|
PDF
|
E10480,
125VAC.
125VDC.
MIL-STD-202,
R460001
R460.002
|
fuse base IEC 269
Abstract: No abstract text available
Text: at 65 VAC/VDC ENVIRONMENTAL SPECIFICATIONS: Operating Temperature: 55°C to 125°C. Shock: MIL-STD-202 , Method 213, Test Condition I (100 G's peak for 6 milliseconds). Vibration: MIL-STD-202 , Method 201 (1055 Hz, .06 in. total excursion). Salt Spray: MIL-STD-202 Method 101, Test Condition B (48 hrs.). Insulation Resistance (After Opening): MIL-STD-202 , Method 302, Test Condition A, (10,000 ohms minimum). Resistance to Soldering Heat: MIL-STD-202 , Method 210, Test Condition F (20 sec. at 260°C). Thermal Shock
|
Original
|
PDF
|
E10480,
SPECIFI54
fuse base IEC 269
|
MF-200
Abstract: mil-std-202 method 304 MF-100 MF25 1K E192 Series mil-std-202 method 108 MIL-STD-202 METHOD 301 E192 MF-12 MF-25
Text: should be performed after stabilization or conditioning periods.) MIL-STD-202 Method 303 MIL-STD-202 , INSULATION RESISTANCE At least 1000M CURRENT NOISE TEST MIL-STD-202 Method 301 1/8W 300V 1 minute 1/4W 500V 1 minute 1/2W 700V 1 minute 1, 2W 750V 1 minute MIL-STD-202 Method 302 100V 1 minute MIL-STD-202 Method 308 5.11 to 9.99 less than 0.05µV/V 10 to 9.99K less then 0.1µV/V 10K to , R within ±(0.5% + 0.05) LOAD LIFE R within ±(1% + 0.05) RESISTANCE TO SOLVENT MIL-STD-202
|
Original
|
PDF
|
MF-25
MF-50
MF-12
MF-100
472ections
MIL-STD-202
MIL-R-10509
MF-200
mil-std-202 method 304
MF-100
MF25 1K
E192 Series
mil-std-202 method 108
MIL-STD-202 METHOD 301
E192
MF-12
MF-25
|
mil-std-202
Abstract: mil-std-202 method 213 method c mil-std-202 method 112 mil-std-202, method 210 1090mhz oscillator mil-std-202 method 108 method 208 mil-std-202 213 mil-std-202 method 215 MIL-STD-202 METHOD 208
Text: % Temperature Testing 100% Start-Up Testing Conditions MIL-STD-202 , Method 213, Condition A MIL-STD-202 , Method 204, Condition A MIL-STD-202 , Method 208 MIL-STD-202 , Method 215 MIL-STD-202 , Method 210, Condition C MIL-STD-202 , Method 107, Condition A MIL-STD-202 , Method 106, 90 to 98% RH 10 Days MIL-STD-202 , Method 211, Condition A MIL-STD-202 , Method 112, Procedure III, Condition C MIL-STD-202 , Method 103 MIL-STD-202 , Method 108, Condition D, 1,000 hrs at +70°C MIL-STD-202 , Method 212, Condition A 10°C Steps
|
Original
|
PDF
|
CCSO-014-1090
1090MHz
CCSO-014-1090
090GHz
-138dBc/Hz
10kHz
-40dBc
MIL-STD-202,
mil-std-202
mil-std-202 method 213 method c
mil-std-202 method 112
mil-std-202, method 210
1090mhz oscillator
mil-std-202 method 108
method 208
mil-std-202 213
mil-std-202 method 215
MIL-STD-202 METHOD 208
|
2001 - Not Available
Abstract: No abstract text available
Text: 207 or MIL-STD-202 Method 105. Capable of 0 to 600 VDC, usually performed up to100K feet at hot or , capacitor breaks. 0 to 50 lb. Maximum. Capacitance: EIA-198 Method 101 or MIL-STD-202 Method 305. Capable , MIL-STD-202 Method 305. Capable of MHz (10KHz to 10MHz) or KHz (100Hz to 100Khz). DWV (Dielectric Withstanding Voltage): EIA-198 Method 103 or MIL-STD-202 Method 301, usually 2.5 X rated voltage. Capable of , Test: EIA-198 Method 210 Cond.âCâ or MIL-STD-202 Method 108, usually 1,000 or 2,000 hours @ rated
|
Original
|
PDF
|
ISO-9001
|
Not Available
Abstract: No abstract text available
Text: - MIL-STD202 202 202 202 1344 MIL-STD- MIL-STD- MIL-STDMethod Method Method Method Method 202 Method 202 Method 202 Method 204 Cond. 204 Cond. 204 Cond. 204 Cond. 2005 Cond. 204 Cond. B 201A 204 Cond. B B B B B III MIL-STD- MIL-STD- MIL-STD- MIL-STD- MIL-STDMIL-STD- MIL-STD- MIL-STD1344 202 202 202 202 202 Method 202 Method 202 Method Method Method Method Method Physical Shock Method , - MIL-STDMIL-STD- MIL-STD- MIL-STD1344 202 202 202 202 202 Method 202 Method 202 Method Method Thermal Shock
|
Original
|
PDF
|
MIL-STD1344
MIL-STD202
|
Not Available
Abstract: No abstract text available
Text: MIL-STD-202 , Method 213, Condition A Mechanical Vibration MIL-STD-202 , Method 204, Condition A Solderability MIL-STD-202 , Method 208 Solvent Resistance MIL-STD-202 , Method 215 Resistance to Soldering Heat MIL-STD-202 , Method 210, Condition C Thermal Shock MIL-STD-202 , Method 107, Condition A Moisture Resistance MIL-STD-202 , Method 106, 90% to 98% RH 10 Days Terminal Strength MIL-STD-202 , Method 211, Condition A Hermetic Seal MIL-STD-202 , Method 112, Procedure III, Condition
|
Original
|
PDF
|
CCSO-014-1090
CCSO-014-1090
10kHz
-35dBc
27-May-2014
239-561-1025-STD-202,
MIL-STD-202,
|