Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MIL-STD-1553 SCHEMA Search Results

    MIL-STD-1553 SCHEMA Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-DSSMDB15MM-010
    Amphenol Cables on Demand Amphenol CS-DSSMDB15MM-010 15-Pin (DB15) Standard Shielded D-Sub Cable - Male / Male 10ft PDF
    CS-DSSMDB25MM-005
    Amphenol Cables on Demand Amphenol CS-DSSMDB25MM-005 25-Pin (DB25) Standard Shielded D-Sub Cable - Male / Male 5ft PDF
    CS-DSSMDB9MF0-002.5
    Amphenol Cables on Demand Amphenol CS-DSSMDB9MF0-002.5 9-Pin (DB9) Standard Shielded D-Sub Cable - Male / Female 2.5ft PDF
    CS-DSSMDB15MM-005
    Amphenol Cables on Demand Amphenol CS-DSSMDB15MM-005 15-Pin (DB15) Standard Shielded D-Sub Cable - Male / Male 5ft PDF
    CS-DSSMDB25MM-002.5
    Amphenol Cables on Demand Amphenol CS-DSSMDB25MM-002.5 25-Pin (DB25) Standard Shielded D-Sub Cable - Male / Male 2.5ft PDF

    Documents mentioning MIL-STD-1553 SCHEMA

    Document Partial File Text Tags Type PDF
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS ADD "+" ON P/N FOR RoHS COMPLIANCE Holt Integrated Circuits MIL-STD-1553 Transformers 1153_Trans Rev. L 1 07/14 MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS ADD "+" ON P/N FOR RoHS COMPLIANCE
    Original PDF
    mil-std-1553
    Aeroflex-Plainview MIL-STD-1553 Glossary A 1553 Military standard that establishes requirements for digital, command/response timedMision multiplexing techniques. In this handbook, 1553 is used as a generic name for MlL-STD-1553(USAF), MIL-STD-1553A, and MlL-STD-1553B. Where a specific revision is referenced, the revision suffix is
    Original PDF
    MIL Page 1 of 2 MIL-STD-1553 Interface
    MIL Page 1 of 2 MIL-STD-1553 Interface Transformers Multiplex Data BUS Pulse Transformers Specifications Units manufactured to MIL-PRF-21038 MIL STD 1553. IMPEDANCE: Greater than 3K ohms over the band from 75kHz to 1MHz. DROOP: 20% max. OVERSHOOT: 1V peak.
    Original PDF
    MIL-STD-1553 INTERFACE TRANSFORMER • qualified
    MIL-STD-1553 INTERFACE TRANSFORMER • qualified for all MIL-STD-1553 applications dual ratio in one package designed, constructed, and tested to meet MIL-PRF-21038 Level C standard package-no standoffs APPLICABLE SPECIFICATIONS • MIL-PRF-21038/27
    Original PDF
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE/DUAL ADD "+" ON P/N FOR RoHS COMPLIANCE * Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 * Common Mode Rejection (CMR) Greater Than 45dB * Impedance Test Frequency from 75Khz to 1MHz
    Original PDF
    MIL Page 1 of 2 MIL-STD-1553 Interface
    MIL Page 1 of 2 MIL-STD-1553 Interface Transformers Multiplex Data BUS Pulse Transformers Specifications Units manufactured to MIL-PRF-21038 MIL STD 1553. IMPEDANCE: Greater than 3K ohms over the band from 75kHz to 1MHz. DROOP: 20% max. OVERSHOOT: 1V peak.
    Original PDF
    MIL Page 1 of 2 MIL-STD-1553 Interface
    MIL Page 1 of 2 MIL-STD-1553 Interface Transformers Multiplex Data BUS Pulse Transformers Specifications Units manufactured to MIL-PRF-21038 MIL STD 1553. IMPEDANCE: Greater than 3K ohms over the band from 75kHz to 1MHz. DROOP: 20% max. OVERSHOOT: 1V peak.
    Original PDF
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE/DUAL ADD "+" ON P/N FOR RoHS COMPLIANCE * Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 * Common Mode Rejection (CMR) Greater Than 45dB * Impedance Test Frequency from 75Khz to 1MHz
    Original PDF
    mac air
    MIL-STD-1553 Interface Transformers Multiplex Data BUS Pulse Transformers Specifications These pulse transformers manufactured to MIL-STD-1553 COMMAND/RESPONSE MULTIPLEX DATA BUS requirements. They also are manufactured to MIL-PRF21038 specifications and are designed to meet MAC AIR
    Original PDF
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE/DUAL ADD "+" ON P/N FOR RoHS COMPLIANCE * Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 * Common Mode Rejection (CMR) Greater Than 45dB * Impedance Test Frequency from 75Khz to 1MHz
    Original PDF
    mil-prf-21038/27-26
    MIL-STD-1553 INTERFACE TRANSFORMERS QUALIFIED TO MIL-PRF-21038/27-26 • qualified for all QPL MIL-STD-1553 applications dual ratio in one package designed, constructed, and tested to meet MIL-PRF-21038 Level C standard package-no standoffs APPLICABLE SPECIFICATIONS
    Original PDF
    mil-prf-21038
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE (Add “+” to end of P/N for RoHS Compliance) < Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 = Common Mode Rejection (CMR) greater than 45dB > Impedance Test Frequency from 75KHz to 1MHz
    Original PDF
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE & DUAL RATIO (Add “+” to end of P/N for RoHS Compliance) < Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 = Common Mode Rejection (CMR) greater than 45dB > Impedance Test Frequency from 75KHz to 1MHz
    Original PDF
    mil-prf-21038
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE/DUAL Ê Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 Ë Common Mode Rejection (CMR) greater than 45dB Ì Impedance test Frequency from 75Khz to 1MHz Í Droop less than 20% Î Overshoot & ringing
    Original PDF
    mil-prf-21038
    MIL-STD-1553 / MIL-PRF-21038 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE Ê Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 Ë Common Mode Rejection (CMR) greater than 45dB Ì Impedance test Frequency from 75Khz to 1MHz Í Droop less than 20% Î Overshoot & ringing
    Original PDF
    mil-prf-21038
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE & DUAL RATIO (Add “+” to end of P/N for RoHS Compliance) < Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 = Common Mode Rejection (CMR) greater than 45dB > Impedance Test Frequency from 75KHz to 1MHz
    Original PDF
    mil-prf-21038
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE & DUAL RATIO (Add “+” to end of P/N for RoHS Compliance) < Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 = Common Mode Rejection (CMR) greater than 45dB > Impedance Test Frequency from 75KHz to 1MHz
    Original PDF
    mil-prf-21038
    MIL-STD-1553 Interface Transformers Multiplex Data BUS Pulse Transformers Specifications z z z z z z z z z z Units manufactured to MIL-PRF-21038 MIL STD 1553. IMPEDANCE: Greater than 3K ohms over the band from 75kHz to 1MHz. DROOP: 20% max. OVERSHOOT: 1V peak.
    Original PDF
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW
    MIL-STD-1553 DATABUS INTERFACE TRANSFORMERS LOW PROFILE SINGLE (Add “+” to end of P/N for RoHS Compliance) ? Droop less than 20% @ Overshoot & Ringing ±1V Max A Pulse Width 2 ms < Designed to Meet MIL-STD-1553 A/B & MIL-PRF-21038 = Common Mode Rejection (CMR) greater than 45dB
    Original PDF